Page 321 of 416

IV. Post-defrost: 1. When engine speed exceeds 700rpm (ignition switch is turned on), defrost work is permitted.
2. Turn on defrost switch, perform defrost work for 12 minutes, if defrost switch is pressed down again during
defrost work, defrost work will stop.
3. During defrost, turn off ignition switch, cancel this defrost.V. Light control: 1. Headlight:
(1) After press remote lock key to close four doors, if remote lock key is pressed down again twice in
succession within in 2s, dipped headlight will extend lighting for 1 minute; if remote unlock key is
pressed down within 60s, dipped headlight control output will be turned off.
(2) During output of 60s low level, if ignition switch is turned on, low level output will stop.
2. Ceiling lamp:
(1) When any of the doors is opened, ceiling lamp illuminates; if door is not closed, ceiling lamp will be
turned off after 10 minutes of delay.
(2) For closing of all doors, ceiling lamp will go out after time delay of 30s;
(3) In case all doors are closed,and ceiling lamp illuminates,ignition switch is turned on,ceiling lamp goes
out.
(4) For remote unlock, ceiling lamp illuminates; in case all doors are closed and ceiling lamp illuminates,
remote lock ceiling lamp goes out.VI. Remote anti-theft 1. Protected state: press lock key on remote controller, while closing four doors, anti-theft indicator lamp will
flashes slowly, indicating that the system enters protected state, when the system is triggered, turn light of the
vehicle will flash, warning horn gives out alarm.
2. Cancel protection: press unlock key on remote controller, while opening left front door, anti-theft indicator
lamp flashes rapidly, if at least one of ignition switch, door is opened within 30 s, anti-theft indicator lamp will
go out; otherwise it will enter secondary anti-theft state.
3. Two stage type protection cancellation: while the system is in triggered state, press any key on the remote
controller, alarm sound will stop, however, the system is still in protected state, and car door is still locked; if the
system continues to receive invasion signal, alarm will ring again after brief stop. To cancel protection completely,
cancel alarm for the first time, then press unlock key once immediately;
4. Secondary anti-theft: after protection is cancelled, if any of ignition switch, door is not opened within 30s,
the system will restore alert status automatically, and lock the car door.
Distribution of centralized controller connector terminals:
Connector on wiring harness, as shown in the figure below (view from outgoing terminal):Centralized Controller System-
Function Inspectior5-134Centralized
controller
Page 322 of 416

Centralized Controller System-Function Inspectior5-135Terminal No.
A1
3
4
5
6
7
8
9
10
11
14
15
19
20
21
22
24
26
27
28
29
30
31
32
33
34
35
36RY
YR
BBL
BR
BL
GR
WR
WB
BR
WG
BW
Gr
VY
BG
WG
BLW
BR
BY
BG
R
O
GR
WG
BLB
BLR
BLPower supply (+)
Speed sensor signal
Engine speed signal
IG2
Spray water signal wiper switch 7#Wiper intermittent position signal (+)
Right front door lamp switch
Left front door lamp switch
Hazard lamp switch
GND
Right rear door lamp switch
Left rear door lamp switch
Rear right glass regulator switch (down)
Rear right glass regulator switch (up)
Turn light switch (right turn)
Turn light switch (left turn)
Defrost switch
Left front door fastener unlocked signal
Left front door fastener locked signal
Anti-theft indicator lamp
Rear left glass regulator switch (down)
Rear left glass regulator switch (up)
Front right glass regulator switch (down)
Front right glass regulator switch (up)
Front left glass regulator switch (down)
Front left glass regulator switch (up)
GND
Antenna Definition of centralized controller terminals:Conductor color Terminal definitionConnector A
Connector B Connector C
Page 325 of 416

Chapter 13 Door Glass Regulating and Power Door Lock ControlSection 1 Door Glass Regulating SystemI. Inspection1. Check basic function
(1) Ignition switch is turned "ON" or within 60 s after ignition switch is turned off.
a. Check when rise key of glass regulator switch is pressed, corresponding glass rises, when release, it stops
rising; when press fall key and hold it, corresponding glass falls, when release, it stops falling.
b. Check when glass regulator main control switch lock switch on driver side is pressed,except which on driver
side, other glass regulator switches do not act.
c. Automatic fall: press corresponding glass regulator switch fall key briefly,corresponding glass
regulator motor works, glass falls down to the end; or falls down until rise key or fall key is pressed again.
Notes:
During automatic glass down, if corresponding glass regulator switch fall key is pressed down and held,
glass regulator is changed into manual fall mode; if corresponding glass regulator switch rise key is pressed down
and held, glass regulator is changed into manual rise mode; if corresponding glass regulator switch rise or fall key
is pressed briefly, glass regulator stops work. Press briefly: less than 300ms; press and hold: more than 300 ms.
(2) Close window remotely.
In case setting protection remotely, if a key is pressed for more than 1s, glass regulator automatic window
rising action will be performed, implementation mode: left front, right front, left rear, right back, in the
process of window rise, only one glass regulator is permitted to act, only after glass regulator up to the top,
could the other glass riser act.
2. Glass reguelator switch on driver sideDoor Glass Regulating and Power Door Lock Control-Door Glass Regulating System5-136Glass regulator switch on driver side
Window on front passenger side
Window on driver side
Rear right window
Rear left window
Window locking switch
Page 326 of 416
(1) Check conductibility of the switch.
Standard
Switch position Terminal Result
On driver side
On front passenger side
Left rear
Right rear
Window locking switchUP 12--13 ON
DOWN12---14 ON
UP 12---5 ON
DOWN12---6 ON
UP 12---9 ON
DOWN12---10 ON
UP 12---1 ON
DOWN12---2 ON
Lock12---3 ON
Unlock12---3 OFFResult
Indicator lamp
illuminates If it does not meet stipulation, replace this switch.
(2) Check indicator lamp on glass riser switch on driver side
Storage battery may be connected with terminal of indicator
lamp directly (as shown in the figure)
Standard
If it does not meet stipulation, replace this switch.
3. Other window glass riser switches (passenger side, left rear, right rear)Door Glass Regulating and Power Door Lock Control-
Door Glass Regulating System5-137Connecting condition
Battery positive - terminal 11
Battery negative - terminal 12Other glass regulator switches
Page 327 of 416

Measuring condition
On driver side,
rear right side
On front passen-
ger side, rear left
sideClockwise
Anticlockwise
Clockwise
Anticlockwise Battery positive -1
Battery negative -2
Battery positive -2
Battery negative -1
Battery positive -2
Battery negative -1
Battery positive -1
Battery negative -2 If it does not meet stipulation, replace this switch.
4. Check door glass riser motor
Notes:
(1) Detect door glass riser motor on driver side and on right rear
side following the same steps.
(2) Detect door glass riser motor on front passenger side and on
left rear side following the same steps.
(3) Connect door glass riser motor terminal with storage
battery, check operation of the motor.
StandardSwitch position Terminal Result
UP 5-7 ON
DOWN 5-8 ONConnecting condition Result
Battery positive - terminal 4
Battery negative - terminal 2 (1) Check conductibility of the switch.
Standard
If it does not meet stipulation, replace this switch.
(2) Check indicator lamp on switch
StandardDoor Glass Regulating and Power Door Lock Control-
Door Glass Regulating System5-140Indicator lamp illumi-
natesStipulationsDriver side, right rear side
Driving
shaft
Anticlockwise
Clockwise
Front passenger side, left rear side
Clockwise
Anticlockwise
Driving shaft
Page 328 of 416
Door Glass Regulating and Power Door Lock Control-
Door Glass Regulating System5-1415. Electric circuit diagramfor door glass regnlating system
Please Refer to "MK WIRING DIAGRAM"
Page 329 of 416
2. Check door lock main control switch (1) Connection of terminals
Standard:Section 2 Power Door Lock Control SystemI. Inspection1. Check basic function
a. When door lock control switch locks, four door locks are locked; when door lock control switch unlocks,
four doors are unlocked.
b. When door lock on driver side is locked using key, four door locks are locked.Terminal No. Door lock state Standard state
12-7 Lock ON
- OFF OFF
12-15 Unlock ONMeasuring condition
Battery positive -1
Battery negative -2
Battery positive -1
Battery negative -2Door Glass Regulating and Power Door Lock Control-
Power Door Lock Control System5-142 If it does not meet stipulation, replace this switch.
3. Fastener inspection
(1)Apply storage battery voltage, check operation of the actuator.
Standard:
If not, replace actuator assembly.Standard state
Unlock
LockLOCKUnlock
Power door lock center control switchBatteryLock
Unlock
Page 332 of 416
Chapter 2 Rear Row Seat AssemblyI. Component Viewrear row seat cushion lockInterior & Exterior Trim and Accessory -Rear Row Seat Assembly6-3headrest pillow
support of headrest pillow
frame of right-rear seatback
cover (cushion) of right-
rear seatback
side hinge of rear seat
arch ring
central hingelock-up handle of seatback
support of lock-up handle of seatback
assembly of right-rear seatback lock-up
assembly of left-rear seatback lock-up
cover (cushion) of left-rear
seatbackframe of left-
rear seatback
side hinge of rear seat
central bracket of rear
seat cushion