Page 59 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-59V5 MR-372-J84-23A100$406.mif
SIEMENS TA2005
Vdiag No.: 14-18
* The immobiliser warning light will flash for a few seconds after the ignition is switched off.DF232
PRESENT
OR
STORED
COMPUTER
1.DEF: Internal electronic fault
NOTESSpecial note:
The fault relates to an internal computer fault.
If the fault is stored, clear the fault from the computer memory.
Switch off the ignition, wait until the end of power latch* then switch the ignition back on and re-establish dialogue:
Check for + 12 V on connection AP4 of component 119.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
Check for earth on connection N of component 119.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF232/DP0TA2005_V18_DF232
Page 60 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-60V5 MR-372-J84-23A100$406.mif
SIEMENS TA2005
Vdiag No.: 14-18
* The immobiliser warning light will flash for a few seconds after the ignition is switched off.DF233
PRESENT
OR
STORED
COMPUTER
1.DEF: Internal electronic fault
NOTESSpecial note:
The fault relates to an internal computer fault.
If the fault is stored, clear the fault from the computer memory.
Switch off the ignition, wait until the end of power latch* then switch the ignition back on and re-establish dialogue:
Check for + 12 V on connection AP4 of component 119.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
Check for earth on connection N of component 119.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF233/DP0TA2005_V18_DF233
Page 61 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-61V5 MR-372-J84-23A100$406.mif
SIEMENS TA2005
Vdiag No.: 14-18
* The immobiliser warning light will flash a few seconds after the ignition is switched off.DF234
PRESENT
OR
STORED
COMPUTER
1.DEF: Internal electronic fault
NOTESSpecial note:
The fault relates to an internal computer fault.
If the fault is stored, clear the fault from the computer memory.
Switch off the ignition, wait until the end of power latch* then switch the ignition back on and re-establish dialogue:
Check for + 12 V on connection AP4 of component 119.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
Check for earth on connection N of component 119.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF234/DP0TA2005_V18_DF234
Page 62 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-62V5 MR-372-J84-23A100$406.mif
SIEMENS TA2005
Vdiag No.: 14-18
Kickdown: instant power request by suddenly pressing the accelerator pedal down hard.DF235
PRESENT
OR
STORED
INVALID PEDAL POSITION MULTIPLEX SIGNAL
1.DEF: Multiplex frames absent or values invalid (fault with the computer generating
the signal or multiplex line connection fault)
NOTESConditions for applying the fault finding procedure to stored faults:
If the fault appears following a road test during which the kickdown function is inactive.
Run a multiplex network test (see 88B, Multiplex).
If the fault is still present, carry out fault finding on the injection system (see 17B, Petrol injection or 13B, Diesel
injection).
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF235/DP0TA2005_V18_DF235
Page 63 of 139
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-63V5 MR-372-J84-23A100$406.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF236
PRESENT
OR
STOREDINVALID ENGINE SPEED MULTIPLEX SIGNAL
1.DEF: Multiplex frames absent or values invalid (fault with the computer generating
the signal or multiplex line connection fault)
NOTESNone.
Run a multiplex network test (see 88B, Multiplex).
If the fault is still present, carry out fault finding on the injection system (see 17B, Petrol injection or 13B, Diesel
injection).
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF236/DP0TA2005_V18_DF236
Page 64 of 139
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-64V5 MR-372-J84-23A100$406.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF237
PRESENT
OR
STOREDINVALID COOLANT TEMPERATURE SIGNAL
1.DEF: Multiplex frames absent or values invalid (fault with the computer generating
the signal or multiplex line connection fault)
NOTESNone.
Run a multiplex network test (see 88B, Multiplex).
If the fault is still present, carry out fault finding on injection system (see 17B, Petrol injection or 13B, Diesel
injection).
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF237/DP0TA2005_V18_DF237
Page 65 of 139
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-65V5 MR-372-J84-23A100$406.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF238
PRESENT
OR
STOREDINVALID RAW ENGINE TORQUE MULTIPLEX SIGNAL
1.DEF: Multiplex frames absent or values invalid (fault with the computer generating
the signal or multiplex line connection fault)
NOTESNone.
Run a multiplex network test (see 88B, Multiplex).
If the fault is still present, carry out fault finding on the injection system (see 17B, Petrol injection or 13B, Diesel
injection).
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF238/DP0TA2005_V18_DF238
Page 66 of 139
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-66V5 MR-372-J84-23A100$406.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF239
PRESENT
OR
STOREDINVALID ACTUAL ENGINE TORQUE MULTIPLEX SIGNAL
1.DEF: Multiplex frames absent or values invalid (fault with the computer generating
the signal or multiplex line connection fault)
NOTESNone.
Run a multiplex network test (see 88B, Multiplex).
If the fault is still present, carry out fault finding on the injection system (see 17B, Petrol injection or 13B, Diesel
injection).
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF239/DP0TA2005_V18_DF239