2007 ISUZU KB P190 ignition

[x] Cancel search: ignition

Page 4028 of 6020

ISUZU KB P190 2007  Workshop Repair Manual 7A2-62  TRANSMISSION CONTROL SYSTEM (AW30–40LE) 
 
Step Action  Value(s)  YES NO 
9   1. Reconnect all previously disconnected harness 
connector(s). 
 2. Clear the DTCs with a scan tool.  
 3. Turn

Page 4030 of 6020

ISUZU KB P190 2007  Workshop Repair Manual 7A2-64  TRANSMISSION CONTROL SYSTEM (AW30–40LE) 
 
 (2) Oil temperature is more than 20 °C (68 °F), and 
water temperature signal is more than 70 °C 
(158 °F). 
 (3) 20 seconds or more passed af

Page 4031 of 6020

ISUZU KB P190 2007  Workshop Repair Manual TRANSMISSION CONTROL SYSTEM (AW30–40LE)  7A2-65 
 
Circuit/System Testing DTC P0741 
Step Action  Value(s)  YES NO 
1  
W as the On-Board Diagnostic (OBD) System Check  
performed?  — Go to 
Step

Page 4032 of 6020

ISUZU KB P190 2007  Workshop Repair Manual 7A2-66  TRANSMISSION CONTROL SYSTEM (AW30–40LE) 
 
Step Action  Value(s)  YES NO 
8   1. Reconnect all previously disconnected harness 
connector(s). 
 2. Clear the DTCs with a scan tool.  
 3. Turn

Page 4034 of 6020

ISUZU KB P190 2007  Workshop Repair Manual 7A2-68  TRANSMISSION CONTROL SYSTEM (AW30–40LE) 
 
 (2) Oil temperature is more than 20 °C (68 °F), and 
water temperature signal is more than 70 °C 
(158 °F). 
 (3) 20 seconds or more passed af

Page 4035 of 6020

ISUZU KB P190 2007  Workshop Repair Manual TRANSMISSION CONTROL SYSTEM (AW30–40LE)  7A2-69 
 
Circuit/System Testing DTC P0742 
Step Action  Value(s)  YES NO 
1  
W as the On-Board Diagnostic (OBD) System Check  
performed? 1. Install the sc

Page 4036 of 6020

ISUZU KB P190 2007  Workshop Repair Manual 7A2-70  TRANSMISSION CONTROL SYSTEM (AW30–40LE) 
 
Step Action  Value(s)  YES NO 
7  Replace the Torque converter (Refer to Section 7A4).
 
Is the action complete?  — Go to 
Step 8 — 
8   1. Rec

Page 4038 of 6020

ISUZU KB P190 2007  Workshop Repair Manual 7A2-72  TRANSMISSION CONTROL SYSTEM (AW30–40LE) 
 
Condition For Setting The DTC 
All of the following conditions are met.  
  • Accumulation of feedback error current value is 
more than 8A.