REMOTE KEYLESS ENTRY SYSTEM
BL-39
< SERVICE INFORMATION >
C
D
E
F
G
H
J
K
L
MA
B
BL
N
O
P
Operation Description
• When a button on the keyfob is operated, the signal is sent from the keyfob and received by the remote key-
less entry receiver.
• The received signal is sent to the BCM and compared with the registered ID number.
• If the ID number matches, the BCM sends the lock/unlock signal to each door lock actuator.
• When the door lock actuators receive this signal, each operates to lock/unlock its door.
• BCM locks all doors with input of LOCK signal from keyfob.
• When an UNLOCK signal is sent from keyfob once, driver's door will be unlocked.
• Then, if an UNLOCK signal is sent from keyfob again within 5 seconds, all other doors will be unlocked.
Remote control entry operation conditions
Auto Lock Function
Operation Description
• Unless the key is inserted into the ignition key cylinder, one of the doors is opened, or the keyfob is operated
within 1 minute after a door lock is unlocked by keyfob operation, all the doors are automatically locked.
The 1 minute timer count is executed by the BCM and after 1 minute, the BCM sends the lock signal to all
doors.
Lock operations are the same as for the remote control entry function.
Remote Control Automatic Back Door Function
Switching from all closed to all open
• When a button on the keyfob is operated, the signal is sent from the keyfob and received by the remote key-
less entry receiver.
• The received signal is sent to the BCM and compared with the registered ID number.
• If the ID number matches, the BCM uses power window serial link communication to send the back door
open signal to the back door control unit
• When the back door control unit receives the back door open signal for 0.5 seconds, if the remote control
automatic back door operation enable conditions are met, the warning chime is sounded and the back door
unlock signal is sent to the back door latch using communication.
• When the back door latch receives the back door unlock signal, it operates the release actuator and
releases to back door latch.
• The back door control unit operates the back door motor to open the back door. (At this time, speed control,
input reverse, and overload reverse control are executed.)
• When the back door is opened to the fully open position, the full-open position is detected with the rotation
sensor, the back door motor is stopped.
• The door held by the back door stays at the full open position.
Full open → full closed operation
• When a button of the keyfob is operated, the signal is sent from the keyfob and received by the remote key-
less entry receiver.
• The received signal is sent to the BCM and compared with the registered ID number.
• If the ID number matches, the BCM uses power window serial link communication to send the back door
close request signal to the back door control unit.
• When the back door control unit receives the back door close request signal for 0.5 seconds, if the remote
control automatic back door operation enable conditions are met, the warning chime is sounded and the
back door motor begins closing the back door.
• The back door control unit operates the magnetic clutch and the back door motor to close the back door. (At
this time, the back door control unit executes speed control, input reverse, and overload reverse control.)
• When the back door comes to the half-latch state, the back door latch detects the half-latch state through
half-latch switch operation. The back door latch latches the back door.
For the automatic back door system operation enable conditions, refer to BL-80
.
Active Check Function
Operation Description
When a door is locked or unlocked by keyfob operation, the vehicle turn signals flash and the horn sounds to
verify operation.
• When a button on the keyfob is operated, the signal is sent from the remote controller and received by the
keyless remote entry receiver.
Keyfob operation Operation condition
Door lock operation (locking)• With key removed (key switch: OFF)
• Closing all doors (door switch: OFF)
Door lock operation (unlocking) With key removed (key switch: OFF)
BL-40
< SERVICE INFORMATION >
REMOTE KEYLESS ENTRY SYSTEM
• The received signal is sent to the BCM and compared with the registered ID number.
• If the ID number matches, the BCM sends the turn signal flashing and horn signal to the IPDM E/R.
• The IPDM E/R flashes the turn signal lamps and sounds the horn for each keyfob operation.
Operating function of hazard and horn reminder
Hazard and Horn Reminder
BCM output to IPDM E/R for horn reminder signal as DATA LINE (CAN-H and CAN-L).
The hazard and horn reminder has C mode (horn chirp mode) and S mode (non-horn chirp mode).
How to change hazard and horn reminder mode
With CONSULT-II
Hazard and horn reminder can be changed using “WORK SUPPORT” mode in “MULTI ANSWER BACK SET".
Without CONSULT-II
Refer to Owner's Manual for instructions.
Interior Lamp Operation
When the following input signals are both supplied:
• all door switches are in the OFF position. (when all the doors are closed);
• interior lamp switch is in DOOR position.
Remote keyless entry system turns on interior lamp and ignition keyhole illumination (for 30 seconds) with
input of UNLOCK signal from keyfob.
For detailed description, refer to LT-101, "
System Description".
Panic Alarm Operation
When key switch is OFF (when ignition key is not inserted in key cylinder), remote keyless entry system turns
on and off horn and headlamp intermittently with input of PANIC ALARM signal from keyfob.
The alarm automatically turns off after 25 seconds or when BCM receives any signal from keyfob.
Keyless Power Window Down (Open) Operation
When keyfob unlock switch is turned ON with ignition switch OFF, and the switch is detected to be ON contin-
uously for more than 1 second, the driver's door and passenger's door power windows are simultaneously
opened.
Power window is operated to open and the operation continues as long as the keyfob unlock switch is
pressed.
CAN Communication System DescriptionINFOID:0000000003532915
Refer to LAN-4.
C mode S mode
Keyfob operation Lock Unlock Lock Unlock
Hazard warning lamp
flashTwiceOnceTwice —
Horn sound Once — — —
REMOTE KEYLESS ENTRY SYSTEM
BL-41
< SERVICE INFORMATION >
C
D
E
F
G
H
J
K
L
MA
B
BL
N
O
P
SchematicINFOID:0000000003532916
WIWA1332E
BL-42
< SERVICE INFORMATION >
REMOTE KEYLESS ENTRY SYSTEM
Wiring Diagram - KEYLES -
INFOID:0000000003532917
WIWA1308E
REMOTE KEYLESS ENTRY SYSTEM
BL-43
< SERVICE INFORMATION >
C
D
E
F
G
H
J
K
L
MA
B
BL
N
O
P
WIWA2047E
BL-44
< SERVICE INFORMATION >
REMOTE KEYLESS ENTRY SYSTEM
Terminal and Reference Value for BCM
INFOID:0000000003532918
Refer to BCS-11, "Terminal and Reference Value for BCM".
Terminal and Reference Value for IPDM E/RINFOID:0000000003532919
Refer to PG-22, "Terminal and Reference Value for IPDM E/R".
WIWA1310E
REMOTE KEYLESS ENTRY SYSTEM
BL-45
< SERVICE INFORMATION >
C
D
E
F
G
H
J
K
L
MA
B
BL
N
O
P
CONSULT-II Function (BCM)INFOID:0000000003532920
CONSULT-II can display each diagnostic item using the diagnostic test modes shown following.
CONSULT-II Start ProcedureINFOID:0000000003532921
Refer to GI-36, "CONSULT-II Start Procedure".
CONSULT-II Application ItemINFOID:0000000003532922
“MULTI REMOTE ENT”
Data Monitor
Active Test
BCM
diagnostic test itemDiagnostic mode Description
Inspection by partWORK SUPPORTSupports inspections and adjustments. Commands are transmitted to the
BCM for setting the status suitable for required operation, input/output sig-
nals are received from the BCM and received date is displayed.
DATA MONITOR Displays BCM input/output data in real time.
ACTIVE TESTOperation of electrical loads can be checked by sending drive signal to
them.
SELF-DIAG RESULTS Displays BCM self-diagnosis results.
CAN DIAG SUPPORT MNTRThe result of transmit/receive diagnosis of CAN communication can be
read.
ECU PART NUMBER BCM part number can be read.
CONFIGURATION Performs BCM configuration read/write functions.
Monitored Item Description
DOOR SW-AS Indicates [ON/OFF] condition of front door switch RH.
DOOR SW-RR Indicates [ON/OFF] condition of rear door switch RH.
DOOR SW-RL Indicates [ON/OFF] condition of rear door switch LH.
DOOR SW-DR Indicates [ON/OFF] condition of front door switch LH.
BACK DOOR SW Indicates [ON/OFF] condition of back door latch.
KEY ON SW Indicates [ON/OFF] condition of key switch.
ACC ON SW Indicates [ON/OFF] condition of ignition switch in ACC position.
IGN ON SW Indicates [ON/OFF] condition of ignition switch in ON position.
KEYLESS PANIC Indicates [ON/OFF] condition of panic signal from keyfob.
KEYLESS UNLOCK Indicates [ON/OFF] condition of unlock signal from keyfob.
KEYLESS LOCK Indicates [ON/OFF] condition of lock signal from keyfob.
KEY CYL LK-SW Indicates [ON/OFF] condition of lock signal from door key cylinder switch.
KEY CYL UN-SW Indicates [ON/OFF] condition of unlock signal from door key cylinder switch.
KEYLESS PBD Indicates [ON/OFF] condition of power back door signal from keyfob.
CDL UNLOCK SW Indicates [ON/OFF] condition of unlock signal from lock/unlock switch.
CDL LOCK SW Indicates [ON/OFF] condition of lock signal from lock/unlock switch.
DOOR SW-RL Indicates [ON/OFF] condition of rear door switch LH.
DOOR SW-RR Indicates [ON/OFF] condition of rear door switch RH.
RKE LCK-UNLCK Indicates [ON/OFF] condition of lock/unlock signal at the same time from keyfob.
RKE KEEP UNLK Indicates [ON/OFF] condition of unlock signal from keyfob.
TRNK OPN MNTR Indicates [ON/OFF] condition of glass open switch.
BL-46
< SERVICE INFORMATION >
REMOTE KEYLESS ENTRY SYSTEM
Work Support
Hazard and horn reminder mode
Auto locking function mode
Panic alarm operation mode
Back door open operation mode
Te s t I t e m D e s c r i p t i o n
FLASHER This test is able to check right and left hazard reminder operation. The right hazard lamp turns on
when “RH” on CONSULT-II screen is touched and the left hazard lamp turns on when "LH" on CON-
SULT-II screen is touched.
POWER WINDOW DOWN This test is able to check power window down operation. The windows are lowered when “ON” on
CONSULT-II screen is touched.
HORN This test is able to check panic alarm and horn reminder operations. The alarm activate for 0.5 sec-
onds after “ON” on CONSULT-II screen is touched.
DOOR LOCK This test is able to check door lock operation. The doors lock and unlock based on the item on CON-
SULT-II screen touched.
TRUNK/BACK DOOR This test is able to check back door actuator operation. The back door is opened when “OPEN” on
CONSULT-II screen is touched.
PSB/PBD OPEN TESTThis test is able to check power back door operation. The power back door is fully opened when
“OPEN” on the CONSULT-II screen is touched if the door operation enable conditions are met.
Te s t I t e m D e s c r i p t i o n
REMO CONT ID REGIST Keyfob ID code can be registered.
REMO CONT ID ERASUR Keyfob ID code can be erased.
REMO CONT ID CONFIR It can be checked whether keyfob ID code is registered or not in this mode.
HORN CHIRP SET Horn chirp function mode can be changed in this mode. The function mode will be changed when
"CHANG SETT" on CONSULT-II screen is touched.
HAZARD LAMP SET Hazard lamp function mode can be changed in this mode. The function mode will be changed when
"CHANG SETT" on CONSULT-II screen is touched.
MULTI ANSWER BACK SETHazard and horn reminder mode can be changed in this mode. The reminder mode will be changed
when “CHANG SETT” on CONSULT-II screen is touched.
AUTO LOCK SETAuto locking function mode can be changed in this mode. The function mode will be changed when
"CHANG SETT" on CONSULT-II screen is touched.
PANIC ALRM SETPanic alarm operation mode can be changed in this mode. The operation mode will be changed when
"CHANG SETT" on CONSULT-II screen is touched.
TRUNK OPEN SETBack door opener operation mode can be changed in this mode. The operation mode will be changed
when "CHANG SETT" on CONSULT-II screen is touched.
PW DOWN SETKeyless power window down (open) operation mode can be changed in this mode. The operation
mode will be changed when "CHANG SETT" on CONSULT-II screen is touched.
MODE 1
(C mode)MODE 2
(S mode)MODE 3MODE 4MODE 5MODE 6
Keyfob
operation Lock Unlock Lock Unlock Lock Unlock Lock Unlock Lock Unlock Lock Unlock
Hazard warning
lamp flashTwiceOnceTwice — — — TwiceOnceTwice — — Once
Horn sound Once———————Once—Once—
MODE 1 MODE 2 MODE 3
Auto locking function 5 minutes Nothing 1 minute
MODE 1 MODE 2 MODE 3
Keyfob operation 0.5 seconds Nothing 1.5 seconds
MODE 1 MODE 2 MODE 3
Keyfob operation 0.5 seconds Nothing 0.5 seconds