INFINITI M35 2007  Factory Service Manual DTC P1553 BATTERY CURRENT SENSOR
EC-1251
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
DTC P1553 BATTERY CURRENT SENSORPFP:294G0
Component DescriptionNBS005LT
The power generatio

Page 2783 of 4647

INFINITI M35 2007  Factory Service Manual EC-1254
[VK45DE]
DTC P1553 BATTERY CURRENT SENSOR
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM gr

Page 2784 of 4647

INFINITI M35 2007  Factory Service Manual DTC P1553 BATTERY CURRENT SENSOR
EC-1255
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
2. CHECK BATTERY CURRENT SENSOR POWER SUPPLY CIRCUIT
1. Disconnect battery current sensor (

Page 2785 of 4647

INFINITI M35 2007  Factory Service Manual EC-1256
[VK45DE]
DTC P1553 BATTERY CURRENT SENSOR
Revision: 2007 April2007 M35/M45
6. CHECK BATTERY CURRENT SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between battery c

Page 2786 of 4647

INFINITI M35 2007  Factory Service Manual DTC P1553 BATTERY CURRENT SENSOR
EC-1257
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
5. Check voltage between ECM terminal 71 (battery current sensor
signal) and ground.
6. If

Page 2787 of 4647

INFINITI M35 2007  Factory Service Manual EC-1258
[VK45DE]
DTC P1554 BATTERY CURRENT SENSOR
Revision: 2007 April2007 M35/M45
DTC P1554 BATTERY CURRENT SENSORPFP:294G0
Component DescriptionNBS005M0
The power generation voltage variable control

Page 2788 of 4647

INFINITI M35 2007  Factory Service Manual DTC P1554 BATTERY CURRENT SENSOR
EC-1259
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Overall Function CheckNBS005M3
Use this procedure to check the overall function of the batt

Page 2790 of 4647

INFINITI M35 2007  Factory Service Manual DTC P1554 BATTERY CURRENT SENSOR
EC-1261
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each terminal and ground.