2007 INFINITI M35 ignition

[x] Cancel search: ignition

Page 1009 of 4647

INFINITI M35 2007  Factory Service Manual BL-76
INTELLIGENT KEY SYSTEM
Revision: 2007 April2007 M35/M45
Terminals and Reference Value for BCMNIS001XE
*1: In the state that hazard reminder operates.
*2: In the state that room lamp switch is in

Page 1013 of 4647

INFINITI M35 2007  Factory Service Manual BL-80
INTELLIGENT KEY SYSTEM
Revision: 2007 April2007 M35/M45
CAUTION:
When CAN COMM  [U1000] and CONTROL UNIT (CAN) [U1010] are displayed, give priority to performing trouble diagnosis.
DATA MONITOR

Page 1017 of 4647

INFINITI M35 2007  Factory Service Manual BL-84
INTELLIGENT KEY SYSTEM
Revision: 2007 April2007 M35/M45
Trouble Diagnosis Symptom ChartNIS001XK
ALL FUNCTIONS OF INTELLIGENT KEY SYSTEM DOES NOT OPERATE
NOTE:
Before performing the diagnosis in

Page 1018 of 4647

INFINITI M35 2007  Factory Service Manual INTELLIGENT KEY SYSTEM
BL-85
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2007 April2007 M35/M45
REMOTE KEYLESS ENTRY FUNCTION MALFUNCTION
NOTE:
Before performing the diagnosis in the following table, check

Page 1020 of 4647

INFINITI M35 2007  Factory Service Manual INTELLIGENT KEY SYSTEM
BL-87
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2007 April2007 M35/M45
HAZARD AND BUZZER REMINDER FUNCTION MALFUNCTION
NOTE:
Before performing the diagnosis in the following table, c

Page 1021 of 4647

INFINITI M35 2007  Factory Service Manual BL-88
INTELLIGENT KEY SYSTEM
Revision: 2007 April2007 M35/M45
POWER WINDOW DOWN FUNCTION MALFUNCTION
NOTE:
Before performing the diagnosis in the following table, check “Trouble Diagnosis Procedure

Page 1022 of 4647

INFINITI M35 2007  Factory Service Manual INTELLIGENT KEY SYSTEM
BL-89
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2007 April2007 M35/M45
Take away warning 
does not operate.Door open to close1. Check door switch.BL-94
2. Check inside key antenna.BL-

Page 1023 of 4647

INFINITI M35 2007  Factory Service Manual BL-90
INTELLIGENT KEY SYSTEM
Revision: 2007 April2007 M35/M45
Check CAN Communication SystemNIS001XL
1. CHECK SELF-DIAGNOSTIC RESULTS
CAUTION:
If CONSULT-II is used with no connection of CONSULT-II CO