Page 3553 of 4647
LT-102
HEADLAMP (FOR CANADA) - DAYTIME LIGHT SYSTEM -
Revision: 2007 April2007 M35/M45
6. CHECK HEADLAMP (RH SIDE) GROUND
1. Remove daytime light relay.
2. Check continuity between front combination lamp RH harness
connector (A) and daytime light relay harness connector (B).
3. Check continuity between daytime light relay harness connector
and ground.
OK or NG
OK >> GO TO 7.
NG >> Repair harness or connector.
7. CHECK DAYTIME LIGHT RELAY
Check continuity between daytime light relay terminals.
OK >> Check headlamp bulb and connecting condition combi-
nation lamp terminal connector.
NG >> Replace daytime light relay.
AB
Continuity
Connector Terminal Connector Terminal
E47 2 E34 3 Yes
SKIB4751E
Daytime light
relay connectorTerminal
GroundContinuity
E34 4 Yes
SKIB4674E
Daytime light relay terminals Continuity
34 Yes
SKIB4660E
Page 3554 of 4647
HEADLAMP (FOR CANADA) - DAYTIME LIGHT SYSTEM -
LT-103
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2007 April2007 M35/M45
8. CHECK CIRCUIT BETWEEN IPDM E/R AND FRONT COMBINATION LAMP
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R connector.
3. Check continuity between IPDM E/R harness connector (A) and
front combination lamp (RH and LH) harness connector (B).
4. Check continuity between IPDM E/R harness connector (A) and
ground.
OK or NG
OK >> Replace IPDM E/R. Refer to PG-31, "Removal and Installation of IPDM E/R" .
NG >> Repair harness or connector.
CircuitAB
Continuity
Connector Terminal Connector Terminal
RH
E727 E47 6
Ye s
LH 28 E54 6
A
GroundContinuity
Connector Terminal
RH
E727
No
LH 28
SKIB4753E
Page 3555 of 4647

LT-104
HEADLAMP (FOR CANADA) - DAYTIME LIGHT SYSTEM -
Revision: 2007 April2007 M35/M45
RH High Beam Does Not Illuminate But LH High Beam IlluminatesNKS003PM
1. CHECK BULB
Check bulb of lamp.
OK or NG
OK >> GO TO 2.
NG >> Replace headlamp bulb.
2. CHECK HEADLAMP INPUT SIGNAL
With CONSULT-II
1. Disconnect front combination lamp RH connector.
2. Select “IPDM E/R” on CONSULT-II and select “ACTIVE TEST” on “SELECT DIAG MODE” screen.
3. Touch “HI” screen.
4. When headlamp HI is operating, check voltage between front
combination lamp RH harness connector and ground. (Head-
lamp high beam repeats ON–OFF every 1 second.)
Without CONSULT-II
1. Disconnect front combination lamp RH connector.
2. Start auto active test. Refer to PG-23, "
Auto Active Test" .
3. When headlamp HI is operating, check voltage between front combination lamp RH harness connector
and ground.
OK or NG
OK >> GO TO 4.
NG >> GO TO 3.
Terminals
Voltage
(Approx.) (+)
(-)
Front combination lamp
RH connectorTerminal
E47 6 Ground Battery voltage
Terminals
Voltage
(Approx.) (+)
(-)
Front combination lamp
RH connectorTerminal
E47 6 Ground Battery voltage
SKIB4749E
Page 3556 of 4647

HEADLAMP (FOR CANADA) - DAYTIME LIGHT SYSTEM -
LT-105
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2007 April2007 M35/M45
3. CHECK CONTINUITY BETWEEN IPDM E/R AND FRONT COMBINATION LAMP
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R connector.
3. Check continuity between IPDM E/R harness connector (A) and
front combination lamp RH harness connector (B).
4. Check continuity between IPDM E/R harness connector (A) and
ground.
OK or NG
OK >> Replace IPDM E/R. Refer to PG-31, "Removal and Installation of IPDM E/R" .
NG >> Repair harness or connector.
4. CHECK HEADLAMP GROUND (1)
1. Turn ignition switch OFF.
2. Remove daytime light relay.
3. Check continuity between front combination lamp RH harness
connector (A) and daytime light relay harness connector (B).
OK or NG
OK >> GO TO 5.
NG >> Repair harness or connector.
5. CHECK HEADLAMP GROUND (2)
Check continuity between daytime light relay harness connector and
ground.
OK or NG
OK >> GO TO 6.
NG >> Repair harness or connector.
AB
Continuity
Connector Terminal Connector Terminal
E7 27 E47 6 Yes
A
GroundContinuity
Connector Terminal
E7 27 No
SKIB4755E
AB
Continuity
Connector Terminal Connector Terminal
E47 2 E34 3 Yes
SKIB4751E
Daytime light relay
connectorTe r m i n a l
GroundContinuity
E34 4 Yes
SKIB4674E
Page 3557 of 4647

LT-106
HEADLAMP (FOR CANADA) - DAYTIME LIGHT SYSTEM -
Revision: 2007 April2007 M35/M45
6. CHECK DAYTIME RELAY
Check continuity between daytime light relay terminals.
OK >> Check connecting condition front combination lamp RH
harness connector.
NG >> Replace daytime light relay.
LH High Beam Does Not Illuminate But RH High Beam IlluminatesNKS003PN
1. CHECK BULB
Check bulb of lamp.
OK or NG
OK >> GO TO 2.
NG >> Replace bulb of lamp.
2. CHECK HEADLAMP INPUT SIGNAL
With CONSULT-II
1. Disconnect front combination lamp LH connector.
2. Select “IPDM E/R” on CONSULT-II and select “ACTIVE TEST” on “SELECT DIAG MODE” screen.
3. Touch “HI” screen.
4. When headlamp high beam is operating, check voltage between
front combination lamp LH harness connector and ground.
(Headlamp high beam repeats ON–OFF every 1 second.)
Without CONSULT-II
1. Disconnect front combination lamp LH connector.
2. Start auto active test. Refer to PG-23, "
Auto Active Test" .
3. When headlamp high beam is operating, check voltage between front combination lamp LH harness con-
nector and ground.
OK or NG
OK >> GO TO 3.
NG >> GO TO 4.
Daytime light relay terminals Continuity
34 Yes
SKIB4660E
Terminals
Voltage
(Approx.) (+)
(-)
Front combination lamp
LH connectorTerminal
E54 6 Ground Battery voltage
Terminals
Voltage
(Approx.) (+)
(-)
Front combination lamp
LH connectorTerminal
E54 6 Ground Battery voltage
SKIB4749E
Page 3558 of 4647

HEADLAMP (FOR CANADA) - DAYTIME LIGHT SYSTEM -
LT-107
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2007 April2007 M35/M45
3. CHECK HEADLAMP GROUND
1. Turn ignition switch OFF.
2. Check continuity front combination lamp harness connector and
ground.
OK or NG
OK >> Check connecting condition front headlamp LH connec-
tor harness.
NG >> Repair harness or connector.
4. CHECK CIRCUIT BETWEEN IPDM E/R AND FRONT COMBINATION LAMP
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R connector and front combination lamp LH connector.
3. Check continuity between IPDM E/R harness connector (A) and
front combination lamp LH harness connector (B).
4. Check continuity between IPDM E/R harness connector (A) and
ground.
OK or NG
OK >> Replace IPDM E/R. Refer to PG-31, "Removal and Installation of IPDM E/R" .
NG >> Repair harness or connector.
Front combination
lamp LH connectorTe r m i n a l
GroundContinuity
E54 2 Yes
SKIB4750E
AB
Continuity
Connector Terminal Connector Terminal
E7 28 E54 6 Yes
A
GroundContinuity
Connector Terminal
E7 28 No
SKIB4757E
Page 3559 of 4647

LT-108
HEADLAMP (FOR CANADA) - DAYTIME LIGHT SYSTEM -
Revision: 2007 April2007 M35/M45
Headlamp Low Beam Does Not Illuminate (Both Sides)NKS003PO
1. CHECK COMBINATION SWITCH INPUT SIGNAL
With CONSULT-II
Select “BCM” on CONSULT-II. With “HEAD LAMP” data monitor,
make sure “HEAD LAMP SW 1” and “HEAD LAMP SW 2” turns ON-
OFF linked with operation of lighting switch.
Without CONSULT-II
Refer to LT- 2 3 9 , "
Combination Switch Inspection" .
OK or NG
OK >> GO TO 2.
NG >> Check lighting switch. Refer to LT- 2 3 9 , "
Combination
Switch Inspection" .
2. HEADLAMP ACTIVE TEST
With CONSULT-II
1. Select “IPDM E/R” on CONSULT-II, and select “ACTIVE TEST”
on “SELECT DIAG MODE” screen.
2. Select “LAMPS” on “SELECT TEST” ITEM screen.
3. Touch “LO” screen.
4. Make sure headlamp low beam operation.
Without CONSULT-II
1. Start auto active test. Refer to PG-23, "
Auto Active Test" .
2. Make sure headlamp low beam operation.
OK or NG
OK >> GO TO 3.
NG >> GO TO 4.
3. CHECK IPDM E/R
1. Select “IPDM E/R” on CONSULT-II, and select “DATA MONI-
TOR” on “SELECT DIAG MODE” screen.
2. Make sure “HL LO REQ” turns ON when lighting switch is in
2ND position.
OK or NG
OK >> Replace IPDM E/R. Refer to PG-31, "Removal and
Installation of IPDM E/R" .
NG >> Replace BCM. Refer to BCS-15, "
Removal and Installa-
tion of BCM" . When lighting switch is 2ND
position: HEAD LAMP SW 1 ON
: HEAD LAMP SW 2 ON
PKIA6325E
Headlamp low beam should operate.
Headlamp low beam should operate.
SKIA5774E
When lighting switch is 2ND position : HL LO REQ ON
SKIA5780E
Page 3560 of 4647

HEADLAMP (FOR CANADA) - DAYTIME LIGHT SYSTEM -
LT-109
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2007 April2007 M35/M45
4. CHECK HEADLAMP INPUT SIGNAL
With CONSULT-II
1. Turn ignition switch OFF.
2. Disconnect front combination lamp RH and LH connector.
3. Select “IPDM E/R” on CONSULT-II. Select “ACTIVE TEST” on “SELECT DIAG MODE” screen.
4. Select “LAMPS” on “SELECT TEST ITEM” screen.
5. Touch “LO” screen.
6. When headlamp low beam is operating, check voltage between
front combination lamp (RH and LH) harness connector and
ground.
Without CONSULT-II
1. Turn ignition switch OFF.
2. Disconnect front combination lamp RH and LH connector.
3. Start auto active test. Refer to PG-23, "
Auto Active Test" .
4. When headlamp low beam is operating, check voltage between front combination lamp (RH and LH) har-
ness connector and ground.
OK or NG
OK >> GO TO 5.
NG >> GO TO 6.
5. CHECK HEADLAMP GROUND
1. Turn ignition switch OFF.
2. Check continuity between front combination lamp (RH and LH)
harness connector and ground.
OK or NG
OK >> Check headlamp harness, connectors, ballasts (HID
control unit), and xenon bulbs. Refer to LT- 11 4 , "
Xenon
Headlamp Trouble Diagnosis" .
NG >> Repair harness or connector.
Terminal
Voltage
(Approx.) (+)
(-)
Front combination lamp
connectorterminal
RH E47 8
Ground Battery voltage
LH E54 8
Te r m i n a l
Voltage
(Approx.) (+)
(-)
Front combination lamp
connectorterminal
RH E47 8
Ground Battery voltage
LH E54 8
SKIB4758E
Front combination lamp
connectorTe r m i n a l
GroundContinuity
RH E47 4
Ye s
LH E54 4
SKIB4759E