Page 1784 of 4366
![INFINITI FX35 2007 Service Manual EC-408
[VQ35DE]
DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Revision: 2006 July 2007 FX35/FX45
Diagnostic ProcedureNBS003R5
1. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOI INFINITI FX35 2007 Service Manual EC-408
[VQ35DE]
DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Revision: 2006 July 2007 FX35/FX45
Diagnostic ProcedureNBS003R5
1. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOI](/manual-img/42/57018/w960_57018-1783.png)
EC-408
[VQ35DE]
DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Revision: 2006 July 2007 FX35/FX45
Diagnostic ProcedureNBS003R5
1. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIR-
CUIT
1. Turn ignition switch OFF.
2. Disconnect EVAP canister purge volume control solenoid valve harness connector.
3. Turn ignition switch ON.
4. Check voltage between EVAP canister purge volume control solenoid valve terminal 1 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.
2. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E211, M41
Harness connectors M82, F102
Harness for open or short between EVAP canister purge volume control solenoid valve and IPDM E/R
Harness for open or short between EVAP canister purge volume control solenoid valve and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
3. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIR-
CUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 45 and EVAP canister purge volume control solenoid valve terminal 2. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK (With CONSULT-II)>>GO TO 4.
OK (Without CONSULT-II)>>GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
PBIB2097E
Voltage: Battery voltage
PBIB0148E
Continuity should exist.
Page 1787 of 4366
![INFINITI FX35 2007 Service Manual DTC P0447 EVAP CANISTER VENT CONTROL VALVE EC-411
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
DTC P0447 EVAP CANISTER VENT CONTROL VALVEPFP:14935
Component Desc INFINITI FX35 2007 Service Manual DTC P0447 EVAP CANISTER VENT CONTROL VALVE EC-411
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
DTC P0447 EVAP CANISTER VENT CONTROL VALVEPFP:14935
Component Desc](/manual-img/42/57018/w960_57018-1786.png)
DTC P0447 EVAP CANISTER VENT CONTROL VALVE EC-411
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
DTC P0447 EVAP CANISTER VENT CONTROL VALVEPFP:14935
Component DescriptionNBS003R8
The EVAP canister vent control valve is located on the EVAP canis-
ter and is used to seal the canister vent.
This solenoid valve responds to signals from the ECM. When the
ECM sends an ON signal, the coil in the solenoid valve is energized.
A plunger will then move to seal the canister vent. The ability to seal
the vent is necessary for the on board diagnosis of other evaporative
emission control system components.
This solenoid valve is used only for diagnosis, and usually remains
opened.
When the vent is closed, under normal purge conditions, the evapo-
rative emission control system is depressurized and allows EVAP
Control System diagnosis.
CONSULT-II Reference Value in Data Monitor ModeNBS003R9
Specification data are reference values.
On Board Diagnosis LogicNBS003RA
PBIB1263E
PBIB1611E
MONITOR ITEM CONDITION SPECIFICATION
VENT CONT/V
Ignition switch: ON OFF
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0447
0447 EVAP canister vent con-
trol valve circuit open An improper voltage signal is sent to ECM
through EVAP canister vent control valve.
Harness or connectors
(EVAP canister vent control valve circuit
is open or shorted.)
EVAP canister vent control valve
Page 1788 of 4366
EC-412
[VQ35DE]
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
Revision: 2006 July 2007 FX35/FX45
DTC Confirmation ProcedureNBS003RB
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm battery voltage is more than 11V at idle.
WITH CONSULT-II
1. Turn ignition switch ON.
2. Select “DATA MONITOR” mode with CONSULT-II.
3. Start engine and wait at least 8 seconds.
4. If 1st trip DTC is detected, go to EC-414, "
Diagnostic Procedure"
.
WITH GST
Follow the procedure “WITH CONSULT-II” above.
SEF058Y
Page 1790 of 4366
![INFINITI FX35 2007 Service Manual EC-414
[VQ35DE]
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
Revision: 2006 July 2007 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do n INFINITI FX35 2007 Service Manual EC-414
[VQ35DE]
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
Revision: 2006 July 2007 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do n](/manual-img/42/57018/w960_57018-1789.png)
EC-414
[VQ35DE]
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
Revision: 2006 July 2007 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureNBS003RD
1. INSPECTION START
Do you have CONSULT-II?
Ye s o r N o
Yes >> GO TO 2.
No >> GO TO 3.
2. CHECK EVAP CANISTER VENT CONTROL VALVE CIRCUIT
With CONSULT-II
1. Turn ignition switch OFF and then turn ON.
2. Select “VENT CONTROL/V” in “ACTIVE TEST” mode with CONSULT-II.
3. Touch “ON/OFF” on CONSULT-II screen.
4. Check for operating sound of the valve.
OK or NG
OK >> GO TO 7.
NG >> GO TO 3.
TER-
MINAL NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
11 7 R / Y EVAP canister vent control
valve [Ignition switch: ON] BATTERY VOLTAGE
(11 - 14V)
Clicking noise should be heard.
PBIB1679E
Page 1791 of 4366
![INFINITI FX35 2007 Service Manual DTC P0447 EVAP CANISTER VENT CONTROL VALVE EC-415
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
3. CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY CIRCUIT
1. INFINITI FX35 2007 Service Manual DTC P0447 EVAP CANISTER VENT CONTROL VALVE EC-415
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
3. CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY CIRCUIT
1.](/manual-img/42/57018/w960_57018-1790.png)
DTC P0447 EVAP CANISTER VENT CONTROL VALVE EC-415
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
3. CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect EVAP canister vent control valve harness connector.
3. Turn ignition switch ON.
4. Check voltage between EVAP canister vent control valve termi- nal 1 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E211, M41
Harness connectors M11, B1
Harness connectors B84, B216
Harness for open or short between EVAP canister vent control valve and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK EVAP CANISTER VENT CONTROL VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND
SHORT 1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 117 and EVAP canister vent control valve terminal 2. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 7.
NG >> GO TO 6. Voltage: Battery voltage
PBIB1611E
PBIB0152E
Continuity should exist.
Page 1792 of 4366
![INFINITI FX35 2007 Service Manual EC-416
[VQ35DE]
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
Revision: 2006 July 2007 FX35/FX45
6. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors M11, B1
Harness connectors B84, B INFINITI FX35 2007 Service Manual EC-416
[VQ35DE]
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
Revision: 2006 July 2007 FX35/FX45
6. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors M11, B1
Harness connectors B84, B](/manual-img/42/57018/w960_57018-1791.png)
EC-416
[VQ35DE]
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
Revision: 2006 July 2007 FX35/FX45
6. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors M11, B1
Harness connectors B84, B216
Harness for open or short between EVAP canister vent control valve and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
7. CHECK RUBBER TUBE FOR CLOGGING
1. Disconnect rubber tube connected to EVAP canister vent control valve.
2. Check the rubber tube for clogging.
OK or NG
OK >> GO TO 8.
NG >> Clean the rubber tube using an air blower.
8. CHECK EVAP CANISTER VENT CONTROL VALVE
Refer to EC-416, "
Component Inspection" .
OK or NG
OK >> GO TO 9.
NG >> Replace EVAP canister vent control valve.
9. CHECK INTERMITTENT INCIDENT
Refer to EC-147, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>> INSPECTION END
Component InspectionNBS003RE
EVAP CANISTER VENT CONTROL VALVE
With CONSULT-II
1. Remove EVAP canister vent control valve from EVAP canister.
2. Check portion B of EVAP canister vent control valve for being
rusted.
If NG, replace EVAP canister vent control valve.
If OK, go to next step.
3. Reconnect harness connectors disconnected.
4. Turn ignition switch ON.
PBIB1033E
Page 1794 of 4366
![INFINITI FX35 2007 Service Manual EC-418
[VQ35DE]
DTC P0448 EVAP CANISTER VENT CONTROL VALVE
Revision: 2006 July 2007 FX35/FX45
DTC P0448 EVAP CANISTER VENT CONTROL VALVEPFP:16935
Component DescriptionNBS003WP
The EVAP canister vent c INFINITI FX35 2007 Service Manual EC-418
[VQ35DE]
DTC P0448 EVAP CANISTER VENT CONTROL VALVE
Revision: 2006 July 2007 FX35/FX45
DTC P0448 EVAP CANISTER VENT CONTROL VALVEPFP:16935
Component DescriptionNBS003WP
The EVAP canister vent c](/manual-img/42/57018/w960_57018-1793.png)
EC-418
[VQ35DE]
DTC P0448 EVAP CANISTER VENT CONTROL VALVE
Revision: 2006 July 2007 FX35/FX45
DTC P0448 EVAP CANISTER VENT CONTROL VALVEPFP:16935
Component DescriptionNBS003WP
The EVAP canister vent control valve is located on the EVAP canis-
ter and is used to seal the canister vent.
This solenoid valve responds to signals from the ECM. When the
ECM sends an ON signal, the coil in the solenoid valve is energized.
A plunger will then move to seal the canister vent. The ability to seal
the vent is necessary for the on board diagnosis of other evaporative
emission control system components.
This solenoid valve is used only for diagnosis, and usually remains
opened.
When the vent is closed, under normal purge conditions, the evapo-
rative emission control system is depressurized and allows EVAP
Control System diagnosis.
CONSULT-II Reference Value in Data Monitor ModeNBS003WQ
Specification data are reference values.
On Board Diagnosis LogicNBS003WR
PBIB1263E
PBIB1611E
MONITOR ITEM CONDITION SPECIFICATION
VENT CONT/V
Ignition switch: ON OFF
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0448
0448 EVAP canister vent con-
trol valve close EVAP canister vent control valve remains
closed under specified driving conditions.
EVAP canister vent control valve
EVAP control system pressure sensor
and the circuit
Blocked rubber tube to EVAP canister
vent control valve
EVAP canister is saturated with water
Page 1795 of 4366
![INFINITI FX35 2007 Service Manual DTC P0448 EVAP CANISTER VENT CONTROL VALVE EC-419
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
DTC Confirmation ProcedureNBS003WS
NOTE:
If DTC Confirmation Proc INFINITI FX35 2007 Service Manual DTC P0448 EVAP CANISTER VENT CONTROL VALVE EC-419
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
DTC Confirmation ProcedureNBS003WS
NOTE:
If DTC Confirmation Proc](/manual-img/42/57018/w960_57018-1794.png)
DTC P0448 EVAP CANISTER VENT CONTROL VALVE EC-419
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
DTC Confirmation ProcedureNBS003WS
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
WITH CONSULT-II
1. Turn ignition switch ON and wait at least 5 seconds.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON and select “DATA MONITOR” mode with CONSULT-II.
4. Start engine and let it idle for at least 1 minute.
5. Repeat next procedures three times.
a. Increase the engine speed up to 3,000 to 3,500 rpm and keep it for 2 minutes and 50 seconds to 3 minutes.
Never exceed 3 minutes.
b. Fully released accelerator pedal and keep engine idle for about 5 seconds.
6. If 1st trip DTC is detected, go to EC-421, "
Diagnostic Procedure"
.
If 1st trip DTC is not detected, go to the next step.
7. Repeat next procedure 20 times.
a. Quickly increase the engine speed up to 4,000 to 4,500 rpm or more and keep it for 25 to 30 seconds.
b. Fully released accelerator pedal and keep engine idle for at least 35 seconds.
8. If 1st trip DTC is detected, go to EC-421, "
Diagnostic Procedure" .
WITH GST
Follow the procedure “WITH CONSULT-II” above.
SEF058Y
PBIB0972E