Page 2247 of 2896

HEADLAMP (FOR CANADA) - DAYTIME LIGHT SYSTEM -
LT-39
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: June 20062007 Versa
Bulb ReplacementEKS00IM5
CAUTION:
After installing bulb, be sure to install plastic cap and bulb socket securely to ensure watertightness.
HEADLAMP (HIGH/LOW)
1. Turn lighting switch OFF.
2. Remove the headlamp. Refer to LT- 2 5 , "
Removal and Installation" .
3. Remove back cover.
4. Unlock retaining spring and remove bulb from headlamp.
PARKING (CLEARANCE) LAMP
1. Turn lighting switch OFF.
2. Remove the headlamp. Refer to LT- 2 5 , "
Removal and Installation" .
3. Turn bulb socket counterclockwise and unlock it.
4. Remove bulb from its socket.
FRONT TURN SIGNAL LAMP
1. Turn lighting switch OFF.
2. Remove the headlamp. Refer to LT- 2 5 , "
Removal and Installation" .
3. Turn bulb socket counterclockwise and unlock it.
4. Remove bulb from its socket.
Removal and InstallationEKS00IM6
REMOVAL
1. Disconnect the negative battery terminal.
2. Remove front bumper fascia. Refer to EI-14, "
FRONT BUMPER" .
3. Remove headlamp bolts (A).
4. Pull headlamp (1) toward the vehicle front, disconnect connec-
tor, and remove headlamp.
INSTALLATION
Installation is in the reverse order of removal.
After installation, perform aiming adjustment. Refer to LT-37, "Aiming Adjustment" .
PKIC1223E
Page 2248 of 2896
LT-40
HEADLAMP (FOR CANADA) - DAYTIME LIGHT SYSTEM -
Revision: June 20062007 Versa
Disassembly and AssemblyEKS00IM7
DISASSEMBLY
1. Remove back cover.
2. Unlock retaining spring and remove bulb (High/Low).
3. Turn parking (clearance) lamp bulb socket counterclockwise and unlock it.
4. Remove parking (clearance) lamp bulb from its socket.
5. Turn front turn signal lamp bulb socket counterclockwise and unlock it.
6. Remove front turn signal lamp bulb from its socket.
7. Remove the bumper stay.
ASSEMBLY
Assembly is in the reverse order of disassembly.
CAUTION:
After installing bulb, be sure to install plastic cap securely to insure water tight seal.
1. Retaining spring 2. Parking (clearance) lamp bulb 3. Parking (clearance) lamp bulb socket
4. Halogen bulb (High/Low) 5. Back cover 6. Front turn signal lamp bulb socket
7. Front turn signal lamp bulb 8. Headlamp housing assembly 9. Bumper stay
A. Screw
WKIA5418E
Page 2253 of 2896

FRONT FOG LAMP
LT-45
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: June 20062007 Versa
Terminals and Reference Values for BCMEKS00HXB
Refer to BCS-12, "Terminals and Reference Values for BCM" .
Terminals and Reference Values for IPDM E/REKS00HXC
Refer to PG-25, "Terminals and Reference Values for IPDM E/R" .
How to Proceed With Trouble DiagnosisEKS00HXD
1. Confirm the symptom or customer complaint.
2. Understand operation description and function description. Refer to LT- 4 1 , "
System Description" .
3. Perform the Preliminary Check. Refer to LT- 4 5 , "
Preliminary Check" .
4. Check symptom and repair or replace the component.
5. Do the front fog lamps operate normally? If YES, GO TO 6. If NO, GO TO 4.
6. INSPECTION END.
Preliminary CheckEKS00HXE
CHECK POWER SUPPLY AND GROUND CIRCUIT FOR BCM
Refer to BCS-16, "BCM Power Supply and Ground Circuit Check" .
CHECK POWER SUPPLY AND GROUND CIRCUIT FOR IPDM E/R
Refer to PG-28, "IPDM E/R Power/Ground Circuit Inspection" .
CONSULT-II Function (BCM)EKS00HXF
Refer to BCS-17, "CONSULT-II Function (BCM)" .
CONSULT-II Function (IPDM E/R)EKS00HXG
Refer to PG-19, "CONSULT-II Function (IPDM E/R)" .
Front Fog lamps Do Not Illuminate (Both Sides)EKS00HXH
1. INSPECT FOG LAMP FUSE
Inspect fog lamp 15A fuse No. 56 in IPDM E/R.
OK or NG
OK >> GO TO 2.
NG >> Repair harness.
2. CHECK COMBINATION SWITCH INPUT SIGNAL
1. Select “BCM” on CONSULT-II. Select “HEAD LAMP” on
“SELECT TEST ITEM” screen.
2. Select “DATA MONITOR” on “SELECT DIAG MODE” screen.
Make sure that “FR FOG SW” turns ON-OFF linked with opera-
tion of fog lamp switch.
With CONSULT-II
Select “BCM” on CONSULT-II. With “HEAD LAMP” data monitor,
make sure “FR FOG SW” turns ON-OFF linked with operation of
front fog lamp switch.
Without CONSULT-II
Refer to LT- 6 8 , "
Combination Switch Inspection" .
OK or NG
OK >> GO TO 3.
NG >> Check combination switch (lighting switch). Refer to LT-68, "
Combination Switch Inspection" . When fog lamp switch is ON : FR FOG SW ON
PKIA7598E
Page 2255 of 2896

FRONT FOG LAMP
LT-47
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: June 20062007 Versa
5. CHECK FOG LAMP INPUT SIGNAL
With CONSULT-II
1. Turn ignition switch OFF.
2. Disconnect front fog lamp connector.
3. Select “IPDM E/R” on CONSULT-II, and select “ACTIVE TEST” on “SELECT DIAG MODE” screen.
4. Select “EXTERNAL LAMPS” on “SELECT TEST ITEM” screen.
5. Touch “FOG” screen.
6. When front fog lamp relay is operating, check voltage between
front fog lamp harness connector and ground.
Without CONSULT-II
1. Turn ignition switch OFF.
2. Disconnect front fog lamp connector.
3. Start auto active test. Refer to PG-21, "
Auto Active Test" .
4. When front fog lamp relay is operating, check voltage between front fog lamp harness connector and
ground.
OK or NG
OK >> GO TO 7.
NG >> GO TO 6.
6. CHECK FOG LAMP CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R connector.
3. Check continuity between IPDM E/R harness connector (A) and
front fog lamp harness connector (B).
OK or NG
OK >> Replace IPDM E/R. Refer to PG-29, "Removal and
Installation of IPDM E/R" .
NG >> Repair harness or connector.
(+)
(−)Voltage
Front fog lamp connector Terminal
RH E28
1 Ground Battery voltage
LH E27
(+)
(−)Voltage
Front fog lamp connector Terminal
RH E28
1 Ground Battery voltage
LH E27
PKIA6276E
CircuitAB
Continuity
Connector Terminal Connector Terminal
RH
E4751 E28
1Yes
LH 50 E27
WKIA4408E
Page 2259 of 2896

TURN SIGNAL AND HAZARD WARNING LAMPS
LT-51
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: June 20062007 Versa
TURN SIGNAL AND HAZARD WARNING LAMPSPFP:26120
Component Parts and Harness Connector LocationEKS00HXZ
System DescriptionEKS00HY0
TURN SIGNAL OPERATION
Power is supplied at all times
through 40A fusible link (letter g , located in the fuse and fusible link box)
to BCM (body control module) terminal 70,
through 10A fuse [No. 8, located in the fuse block (J/B)]
to BCM terminal 57,
through 10A fuse [No. 13, located in the fuse block (J/B)]
to combination meter terminal 27.
With the ignition switch in the ON or START position, power is supplied
through 10A fuse [No. 6, located in fuse block (J/B)]
to BCM terminal 38,
through 10A fuse [No. 3, located in fuse block (J/B)]
to combination meter terminal 28.
With the ignition switch in the ACC or ON position, power is supplied
through 10A fuse [No. 20, located in the fuse block (J/B)]
to BCM terminal 11.
Ground is supplied
to BCM terminal 67 and
to combination meter terminals 21, 22 and 23
through grounds M57 and M61.
LH Turn Signal Lamp
When the turn signal switch is moved to the left turn position, the BCM receives an input signal requesting left
turn signals to flash. The BCM then supplies power
through BCM terminal 60
to front combination lamp LH terminal 4 and
to rear combination lamp LH terminal 6.
1. BCM M18 and M20 (view with glove
box removed)2. Hazard switch M55 3. Combination switch (lighting switch)
M28
4. Combination meter M24
WKIA5493E
Page 2260 of 2896

LT-52
TURN SIGNAL AND HAZARD WARNING LAMPS
Revision: June 20062007 Versa
Ground is supplied
to front combination lamp LH terminal 5
through grounds E15 and E24,
to rear combination lamp LH terminal 1
through grounds B7 and B19.
The BCM also sends a request, via the CAN communication lines, to the combination meter to flash the left
turn signal indicator. The unified meter control unit in the combination meter supplies ground to the left turn
signal indicator lamp and activates the audible turn signal indicator.
With power, ground and input supplied, the BCM controls the flashing of the turn signal lamps.
RH Turn Signal Lamp
When turn signal switch is moved to the right turn position, the BCM receives an input signal requesting right
turn signals to flash. The BCM then supplies power
through BCM terminal 61
to front combination lamp RH terminal 4 and
to rear combination lamp RH terminal 6.
Ground is supplied
to front combination lamp RH terminal 5
through grounds E15 and E24,
to rear combination lamp RH terminal 1
through grounds B117, B132 and B402.
The BCM also sends a request, via the CAN communication lines, to the combination meter to flash the right
turn signal indicator. The unified meter control unit in the combination meter supplies ground to the right turn
signal indicator lamp and activates the audible turn signal indicator.
With power, ground and input supplied, the BCM controls the flashing of the turn signal lamps.
HAZARD LAMP OPERATION
Power is supplied at all times
through 40A fusible link (letter g , located in fuse, fusible link and relay box)
to BCM terminal 70,
through 10A fuse [No. 8, located in fuse block (J/B)]
to BCM terminal 57,
through 10A fuse [No. 13, located in fuse block (J/B)]
to combination meter terminal 27.
Ground is supplied
to hazard switch terminal 1,
to BCM terminal 67, and
to combination meter terminals 21, 22 and 23
through grounds M57 and M61.
When hazard switch is depressed, ground is supplied
through hazard switch terminal 2
to BCM terminal 29.
BCM then supplies power
to front combination lamp LH terminal 4 and
to rear combination lamp LH terminal 6
through BCM terminal 60,
to front combination lamp RH terminal 4 and
to rear combination lamp RH terminal 6
through BCM terminal 61.
Ground is supplied
to front combination lamp LH and RH terminal 5
through grounds E15 and E24,
Page 2261 of 2896

TURN SIGNAL AND HAZARD WARNING LAMPS
LT-53
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: June 20062007 Versa
to rear combination lamp LH terminal 1
through grounds B7 and B19,
to rear combination lamp RH terminal 1
through grounds B117, B132 and D402.
The BCM also supplies input to combination meter across the CAN communication lines. This input is pro-
cessed by unified meter control unit in combination meter, which in turn supplies ground to the left and right
turn signal indicator lamps.
With power and input supplied, BCM controls flashing of hazard warning lamps.
REMOTE KEYLESS ENTRY SYSTEM OPERATION
Power is supplied at all times
through 40A fusible link (letter g , located in fuse, fusible link and relay box)
to BCM terminal 70,
through 10A fuse [No. 13, located in fuse block (J/B)]
to combination meter terminal 27.
Ground is supplied
to BCM terminal 67 and
to combination meter terminals 21, 22 and 23
through grounds M57 and M61.
When the remote keyless entry system is triggered by input from the keyfob, the BCM supplies power
through BCM terminal 60
to front combination lamp LH terminal 4 and
to rear combination lamp LH terminal 6,
through BCM terminal 61
to front turn signal lamp RH terminal 4 and
to rear combination lamp RH terminal 6.
Ground is supplied
to front combination lamp LH and RH terminals 5
through grounds E15 and E24,
to rear combination lamp LH terminal 1
through grounds B7 and B19,
to rear combination lamp RH terminal 1
through grounds B117, B132 and D402.
The BCM also supplies input to combination meter via the CAN communication lines. This input is processed
by the unified meter control unit in combination meter, which in turn supplies ground to the left and right turn
signal indicator lamps.
With power and ground supplied, BCM controls flashing of hazard warning lamps when keyfob is used to acti-
vate remote keyless entry system.
COMBINATION SWITCH READING FUNCTION
Refer toBCS-3, "COMBINATION SWITCH READING FUNCTION" .
CAN Communication System DescriptionEKS00HY1
Refer to LAN-4, "CAN Communication System" .
Page 2262 of 2896
LT-54
TURN SIGNAL AND HAZARD WARNING LAMPS
Revision: June 20062007 Versa
SchematicEKS00HY3
WKWA4974E