2006 MERCEDES-BENZ SPRINTER ignition

[x] Cancel search: ignition

Page 196 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual TEST ACTION APPLICABILITY
4 Turn the ignition off.
Disconnect the Fuel Pump Module harness connector.
Disconnect the Instrument Cluster C1 harness connector.
Measure the resistance of the Fuel Level S

Page 197 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual Symptom:
FUEL LEVEL SENSOR SHORT TO GROUND
POSSIBLE CAUSES
FUEL LEVEL SENSOR
FUEL LEVEL SENSOR CIRCUITS SHORTED TOGETHER
INSTRUMENT CLUSTER
FUEL LEVEL SENSOR SIGNAL (+) SHORT TO GROUND
TEST ACTION APP

Page 198 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual Symptom:
INSTRUMENT CLUSTER INTERNAL FAILURE B1043
POSSIBLE CAUSES
CAN BUS FAILURE
INSTRUMENT CLUSTER
TEST ACTION APPLICABILITY
1 If this fault is present, scan the Engine Control Module and/or Transm

Page 199 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual Symptom:
INSTRUMENT CLUSTER INTERNAL FAILURE B1053
POSSIBLE CAUSES
CAN BUS FAILURE
INSTRUMENT CLUSTER
TEST ACTION APPLICABILITY
1 If this fault is present, scan the Engine Control Module and/or Transm

Page 201 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual Symptom:
NO CAN COMMUNICATION WITH ABS
POSSIBLE CAUSES
DTC PRESENT
OPEN CAN CIRCUITS AT INSTRUMENT CLUSTER
INSTRUMENT CLUSTER
CHECK POWERS AND GROUNDS TO THE AFFECTED MODULE
OPEN CAN CIRCUITS AT CAB
C

Page 202 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual TEST ACTION APPLICABILITY
5 Turn the ignition off to the lock position.
Disconnect the Instrument Cluster C1 harness connector.
Measure the resistance between the CAN C Bus (+) circuit and the CAN C B

Page 203 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual Symptom:
NO CAN COMMUNICATION WITH ECM
POSSIBLE CAUSES
DTC PRESENT
OPEN CAN CIRCUITS AT INSTRUMENT CLUSTER
INSTRUMENT CLUSTER
CHECK POWERS AND GROUNDS TO THE AFFECTED MODULE
OPEN CAN CIRCUITS AT ECM
E

Page 204 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual TEST ACTION APPLICABILITY
5 Turn the ignition off to the lock position.
Disconnect the Instrument Cluster C1 harness connector.
Reconnect the ECM harness connector.
Measure the resistance between the