LT-2Revision: November 20092006 QX56
System Description ..............................................
... 48
OUTLINE .......................................................... ... 48
COMBINATION SWITCH READING FUNCTION ... 48
EXTERIOR LAMP BATTERY SAVER CONTROL ... 48
DELAY TIMER FUNCTION .............................. ... 48
CAN Communication System Description ........... ... 48
Major Components and Functions ....................... ... 48
Schematic ............................................................ ... 49
Wiring Diagram — AUTO/L — ............................. ... 50
Terminals and Reference Values for BCM ........... ... 53
Terminals and Reference Values for IPDM E/R ... ... 54
How to Proceed With Trouble Diagnosis ............. ... 55
Preliminary Check ............................................... ... 55
SETTING CHANGE FUNCTIONS .................... ... 55
CHECK POWER SUPPLY AND GROUND CIR-
CUIT ................................................................. ... 55
CONSULT-II Function (BCM) ............................... ... 57
CONSULT-II OPERATION ................................ ... 57
WORK SUPPORT ............................................ ... 58
DATA MONITOR ............................................... ... 58
ACTIVE TEST .................................................. ... 59
SELF-DIAGNOSTIC RESULTS ........................ ... 59
CONSULT-II Function (IPDM E/R) ....................... ... 60
CONSULT-II OPERATION ................................ ... 60
DATA MONITOR ............................................... ... 61
ACTIVE TEST .................................................. ... 61
Trouble Diagnosis Chart by Symptom ................. ... 62
Lighting Switch Inspection ................................... ... 62
Optical Sensor System Inspection ....................... ... 63
Optical Sensor ..................................................... ... 64
REMOVAL AND INSTALLATION ...................... ... 64
HEADLAMP AIMING CONTROL ........................... ... 65
System Description .............................................. ... 65
Wiring Diagram — H/AIM — ................................ ... 66
Headlamp Aiming Switch ..................................... ... 68
REMOVAL AND INSTALLATION ...................... ... 68
Switch Circuit Inspection ..................................... ... 68
FRONT FOG LAMP ............................................... ... 69
Component Parts and Harness Connector Location ... 69
System Description .............................................. ... 69
OUTLINE .......................................................... ... 69
COMBINATION SWITCH READING FUNCTION ... 70
EXTERIOR LAMP BATTERY SAVER CONTROL ... 70
CAN Communication System Description ........... ... 70
Wiring Diagram — F/FOG — ............................... ... 71
Terminals and Reference Values for BCM ........... ... 73
Terminals and Reference Values for IPDM E/R ... ... 74
How to Proceed With Trouble Diagnosis ............. ... 74
Preliminary Check ............................................... ... 75
CHECK POWER SUPPLY AND GROUND CIR-
CUIT ................................................................. ... 75
CONSULT-II Functions ........................................ ... 76
Front Fog Lamps Do Not Illuminate (Both Sides) ... 76
Front Fog Lamp Does Not Illuminate (One Side) ... 77
Aiming Adjustment ............................................... ... 78
Bulb Replacement ............................................... ... 79
FRONT FOG LAMP .......................................... ... 79INSTALLATION ................................................
... 79
Removal and Installation ...................................... ... 79
FRONT FOG LAMP .......................................... ... 79
INSTALLATION ................................................ ... 79
TURN SIGNAL AND HAZARD WARNING LAMPS ... 80
Component Parts and Harness Connector Location ... 80
System Description .............................................. ... 80
OUTLINE .......................................................... ... 80
TURN SIGNAL OPERATION ............................ ... 80
HAZARD LAMP OPERATION .......................... ... 81
REMOTE KEYLESS ENTRY SYSTEM OPERA-
TION ................................................................. ... 82
COMBINATION SWITCH READING FUNCTION ... 82
CAN Communication System Description ........... ... 82
Schematic ............................................................ ... 83
Wiring Diagram — TURN — ................................ ... 84
Terminals and Reference Values for BCM ........... ... 87
How to Proceed With Trouble Diagnosis ............. ... 88
Preliminary Check ................................................ ... 89
CHECK POWER SUPPLY AND GROUND CIR-
CUIT .................................................................. ... 89
CONSULT-II Function (BCM) ............................... ... 90
CONSULT-II OPERATION ................................ ... 90
DATA MONITOR ............................................... ... 91
ACTIVE TEST ................................................... ... 91
Front Turn Signal Lamp Does Not Operate ......... ... 92
Door Mirror Turn Signal Lamp Does Not Operate ... 93
Rear Turn Signal Lamp Does Not Operate .......... ... 94
Hazard Warning Lamp Does Not Operate But Turn
Signal Lamps Operate ......................................... ... 95
Turn Signal Indicator Lamp Does Not Operate .... ... 96
Bulb Replacement ................................................ ... 97
TURN SIGNAL LAMP (FRONT) ....................... ... 97
TURN SIGNAL LAMP (REAR) .......................... ... 97
Removal and Installation ...................................... ... 97
FRONT TURN SIGNAL LAMP .......................... ... 97
REAR TURN SIGNAL LAMP ............................ ... 97
LIGHTING AND TURN SIGNAL SWITCH ............. ... 98
Removal and Installation ...................................... ... 98
REMOVAL ........................................................ ... 98
INSTALLATION ................................................ ... 98
HAZARD SWITCH .................................................. ... 99
Removal and Installation ...................................... ... 99
REMOVAL ........................................................ ... 99
INSTALLATION ................................................ ... 99
COMBINATION SWITCH ....................................... .100
Wiring Diagram — COMBSW — ......................... .100
Combination Switch Reading Function ................ .101
CONSULT-II Function (BCM) ............................... .101
CONSULT-II OPERATION ................................ .101
DATA MONITOR ............................................... .102
Combination Switch Inspection ............................ .103
Removal and Installation ...................................... .105
Switch Circuit Inspection ...................................... .105
STOP LAMP ........................................................... .106
System Description .............................................. .106
Wiring Diagram — STOP/L — ............................. .107
Bulb Replacement ................................................ .108
HIGH-MOUNTED STOP LAMP ........................ .108
TURN SIGNAL AND HAZARD WARNING LAMPSLT-93
C
DE
F
G H
I
J
L
M A
B
LT
Revision: November 2009 2006 QX56
4. CHECK GROUND
1. Check continuity between front turn/fog lamp LH harness con- nector E101 terminal 3 and ground.
2. Check continuity between front turn/fog lamp RH harness con- nector E102 terminal 3 and ground.
OK or NG
OK >> GO TO 5.
NG >> Repair harness or connector.
5. CHECK BULB
Check bulb standard of each turn signal lamp is correct. Refer to LT- 1 7 5 , "
Exterior Lamp" .
OK or NG
OK >> Replace BCM if turn signal lamps do not work after setting the connector again. Refer to BCS-20,
"BCM" .
NG >> Replace turn signal lamp bulb. Refer to LT- 3 1 , "
FRONT PARKING LAMP (INNER OR
OUTER)"LT- 3 1 , "FRONT PARKING LAMP (INNER OR OUTER)" .
Door Mirror Turn Signal Lamp Does Not OperateEKS00GGS
1. CHECK COMBINATION SWITCH INPUT SIGNAL
With CONSULT-II
Select "BCM" on CONSULT-II. With "FLASHER" data monitor, make
sure "TURN SIGNAL R" and "TURN SIGNAL L" turns ON-OFF
linked with operation of lighting switch.
Without CONSULT-II
Refer to LT- 1 0 3 , "
Combination Switch Inspection" .
OK or NG
OK >> GO TO 2.
NG >> Check lighting switch. Refer to LT- 1 0 3 , "
Combination Switch Inspection" .
2. ACTIVE TEST
With CONSULT-II
1. Select "FLASHER" during active test. Refer to LT- 9 1 , "
ACTIVE
TEST" .
2. Make sure "FLASHER RH" and "FLASHER LH" operate.
Without CONSULT-II
GO TO 3.
OK or NG
OK >> Replace BCM. Refer to BCS-20, "REMOVAL AND
INSTALLATION" .
NG >> GO TO 3. 3 - Ground
: Continuity should exist.
3 - Ground : Continuity should exist.
WKIA1891E
When lighting switch is in
TURN RH position : TURN SIGNAL R ON
When lighting switch is in
TURN LH position : TURN SIGNAL L ON
SKIA4499E
SKIA6190E