Page 494 of 3383

INFINITI QX56 2006  Factory Service Manual TROUBLE DIAGNOSISATC-93
C
DE
F
G H
I
K L
M A
B
AT C
Revision: November 2009 2006 QX56
Front Blower Motor CircuitEJS003XS
SYMPTOM:
Blower motor operation is malfunctioning.
INSPECTION FLOW
*1 .AT C -

Page 495 of 3383

INFINITI QX56 2006  Factory Service Manual ATC-94
TROUBLE DIAGNOSIS
Revision: November 20092006 QX56
SYSTEM DESCRIPTION
Component Parts
Blower speed control system components are:
Front air control
Variable blower control 
Front blower moto

Page 496 of 3383

INFINITI QX56 2006  Factory Service Manual TROUBLE DIAGNOSISATC-95
C
DE
F
G H
I
K L
M A
B
AT C
Revision: November 2009 2006 QX56
Blower Speed Compensation - Sunload
When the in-vehicle temperature and the set temperature are very close, the bl

Page 497 of 3383

INFINITI QX56 2006  Factory Service Manual ATC-96
TROUBLE DIAGNOSIS
Revision: November 20092006 QX56
1. CHECK FUSES
Check 20A fuses [No. 24 and 27 (Located in the fuse and fusible link box)]. For fuse layout. Refer to  PG-77,
"FUSE AND FUSIBLE

Page 498 of 3383

INFINITI QX56 2006  Factory Service Manual TROUBLE DIAGNOSISATC-97
C
DE
F
G H
I
K L
M A
B
AT C
Revision: November 2009 2006 QX56
5. CHECK FRONT BLOWER MOTOR RELAY (SWITCH SIDE) CIRCUIT FOR OPEN
Check continuity between front blower motor relay

Page 499 of 3383

INFINITI QX56 2006  Factory Service Manual ATC-98
TROUBLE DIAGNOSIS
Revision: November 20092006 QX56
9. CHECK FRONT BLOWER MOTOR RELAY (COIL SIDE) GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Check continuity between front blower motor relay

Page 500 of 3383

INFINITI QX56 2006  Factory Service Manual TROUBLE DIAGNOSISATC-99
C
DE
F
G H
I
K L
M A
B
AT C
Revision: November 2009 2006 QX56
14. CHECK BLOWER MOTOR GROUND CIRCUIT
Check continuity between front blower motor harness connector
M62 terminal 1

Page 501 of 3383

INFINITI QX56 2006  Factory Service Manual ATC-100
TROUBLE DIAGNOSIS
Revision: November 20092006 QX56
COMPONENT INSPECTION
Front Blower Motor Relay
Check continuity between terminals by supplying 12 volts and
ground to coil side terminals of r