2006 INFINITI M35 ground

[x] Cancel search: ground

Page 2442 of 5621

INFINITI M35 2006  Factory Service Manual DTC P0011, P0021 IVT CONTROL
EC-899
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2006 January2006 M35/M45
3. CHECK INTAKE VALVE TIMING CONTROL POSITION SENSOR POWER SUPPLY CIRCUIT
1. Disconnect intake

Page 2443 of 5621

INFINITI M35 2006  Factory Service Manual EC-900
[VK45DE]
DTC P0011, P0021 IVT CONTROL
Revision: 2006 January2006 M35/M45
6. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors F102, M72
Harness for open or short between intake

Page 2444 of 5621

INFINITI M35 2006  Factory Service Manual DTC P0011, P0021 IVT CONTROL
EC-901
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2006 January2006 M35/M45
9. CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1. Reconnect ECM harn

Page 2446 of 5621

INFINITI M35 2006  Factory Service Manual DTC P0011, P0021 IVT CONTROL
EC-903
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2006 January2006 M35/M45
4. Visually check the sensor for chipping.
5. Check resistance as shown below.
6. If NG, repla

Page 2449 of 5621

INFINITI M35 2006  Factory Service Manual EC-906
[VK45DE]
DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATER
Revision: 2006 January2006 M35/M45
Specification data are reference values and are measured between each terminal and ground.
Pulse s

Page 2451 of 5621

INFINITI M35 2006  Factory Service Manual EC-908
[VK45DE]
DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATER
Revision: 2006 January2006 M35/M45
Specification data are reference values and are measured between each terminal and ground.
Pulse s

Page 2452 of 5621

INFINITI M35 2006  Factory Service Manual DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATER
EC-909
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2006 January2006 M35/M45
2. CHECK AIR FUEL RATIO (A/F) SENSOR 1 POWER SUPPLY CIRCUIT
1. Disconnec

Page 2457 of 5621

INFINITI M35 2006  Factory Service Manual EC-914
[VK45DE]
DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
Revision: 2006 January2006 M35/M45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do no