2006 INFINITI M35 Body

[x] Cancel search: Body

Page 1753 of 5621

INFINITI M35 2006  Factory Service Manual EC-210
[VQ35DE]
DTC P0101 MAF SENSOR
Revision: 2006 January2006 M35/M45
3. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten two ground screws on the body. 
Refer to EC-172

Page 1761 of 5621

INFINITI M35 2006  Factory Service Manual EC-218
[VQ35DE]
DTC P0102, P0103 MAF SENSOR
Revision: 2006 January2006 M35/M45
3. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten two ground screws on the body. 
Refer to

Page 1767 of 5621

INFINITI M35 2006  Factory Service Manual EC-224
[VQ35DE]
DTC P0112, P0113 IAT SENSOR
Revision: 2006 January2006 M35/M45
Diagnostic ProcedureNBS004V9
1. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten two ground

Page 1772 of 5621

INFINITI M35 2006  Factory Service Manual DTC P0117, P0118 ECT SENSOR
EC-229
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2006 January2006 M35/M45
Diagnostic ProcedureNBS004VG
1. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen

Page 1777 of 5621

INFINITI M35 2006  Factory Service Manual EC-234
[VQ35DE]
DTC P0122, P0123 TP SENSOR
Revision: 2006 January2006 M35/M45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground

Page 1782 of 5621

INFINITI M35 2006  Factory Service Manual DTC P0125 ECT SENSOR
EC-239
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2006 January2006 M35/M45
DTC Confirmation ProcedureNBS004VT
CAUTION:
Be careful not to overheat engine.
NOTE:
If  DTC  Confirma

Page 1785 of 5621

INFINITI M35 2006  Factory Service Manual EC-242
[VQ35DE]
DTC P0127 IAT SENSOR
Revision: 2006 January2006 M35/M45
b. Select “DATA MONITOR” mode with CONSULT-II.
c. Check the engine coolant temperature.
d. If the engine coolant temperature

Page 1795 of 5621

INFINITI M35 2006  Factory Service Manual EC-252
[VQ35DE]
DTC P0130, P0150 A/F SENSOR 1
Revision: 2006 January2006 M35/M45
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by