2005 NISSAN X-TRAIL ignition

[x] Cancel search: ignition

Page 1314 of 4555

NISSAN X-TRAIL 2005  Service Repair Manual EC-910
[QR (WITHOUT EURO-OBD)]
FUEL PUMP CIRCUIT
 
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring in

Page 1315 of 4555

NISSAN X-TRAIL 2005  Service Repair Manual FUEL PUMP CIRCUIT
EC-911
[QR (WITHOUT EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
 
3. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors M17, B1
Fuse block (J/B) connector M1
15A fuse
Ha

Page 1317 of 4555

NISSAN X-TRAIL 2005  Service Repair Manual FUEL PUMP CIRCUIT
EC-913
[QR (WITHOUT EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
 
Component InspectionEBS0114S
FUEL PUMP RELAY
Check continuity between terminals 3 and 5 under the following con-
ditions.
F

Page 1320 of 4555

NISSAN X-TRAIL 2005  Service Repair Manual EC-916
[QR (WITHOUT EURO-OBD)]
REFRIGERANT PRESSURE SENSOR
 
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when me

Page 1322 of 4555

NISSAN X-TRAIL 2005  Service Repair Manual EC-918
[QR (WITHOUT EURO-OBD)]
REFRIGERANT PRESSURE SENSOR
 
3. CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY CIRCUIT
1. Disconnect refrigerant pressure sensor harness connector.
2. Turn ignition swi

Page 1324 of 4555

NISSAN X-TRAIL 2005  Service Repair Manual EC-920
[QR (WITHOUT EURO-OBD)]
ELECTRICAL LOAD SIGNAL
 
ELECTRICAL LOAD SIGNALPFP:25350
CONSULT-II Reference Value in Data Monitor ModeEBS01FFG
Specification data are reference values.
MONITOR ITEM CO

Page 1326 of 4555

NISSAN X-TRAIL 2005  Service Repair Manual EC-922
[QR (WITHOUT EURO-OBD)]
ELECTRICAL LOAD SIGNAL
 
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuri

Page 1328 of 4555

NISSAN X-TRAIL 2005  Service Repair Manual EC-924
[QR (WITHOUT EURO-OBD)]
ELECTRICAL LOAD SIGNAL
 
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuri