Page 201 of 1500
SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-201
STEP 21. Check the wiring harness between horn relay
connector A-06X (terminal 4) and horn (HIGH) connector
A-37 (terminal 1).
Q: Is the wiring harness between horn relay connector
A-06X (terminal 4) and horn (HIGH) connector A-37
(terminal 1) in good condition?
YES : Replace the ETACS-ECU. Verify that the horn sounds
normally.
NO : The wiring harness may be damaged or the
connector(s) may have loose, corroded or damaged
terminals, or terminals pushed back in the connector.
Repair the wiring harness as necessary. Verify that
the horn sounds normally.
Page 203 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-203
STEP 2. Check the input signal (by using the pulse check
mode of the monitor).
Check the input signals from the following switches:
Key reminder switch
Hazard warning lamp switch
To prevent damage to diagnostic tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting diagnostic tool
MB991958.
(1) Connect diagnostic tool MB991958.Refer to "How to
connect SWS monitor P.54B-13."
(2) Operate diagnostic tool MB991958 according to the
procedure below to display "Pulse check."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "Pulse Checking."
(3) Check the switches (see table below) applicable for the
input signal check are operated.
(4) Check diagnostic tool MB991958 sounds or not.
Q: When the key reminder switch and the hazard warning
lamp switch are operated, does diagnostic tool
MB991958 sound in each case?
Buzzer of diagnostic tool MB991958 sounds normally. :
Replace the ETACS-ECU. Verify that the encrypted
code can be registered in the transmitter.
diagnostic tool MB991958 does not sound when the
ignition key is removed and reinserted : Refer to
Inspection Procedure N-1 "ETACS-ECU does not
receive any signal from the key reminder switch
P.54B-432."
diagnostic tool MB991958 does not sound when the
hazard warning lamp switch is turned from "OFF" to
"ON" : Refer to Inspection Procedure N-2 "ETACS-ECU
does not receive any signal from the hazard warning
lamp switch P.54B-436." ITEM NAME CHECK CONDITION
Key reminder switch Remove and reinsert the
ignition key
Hazard warning lamp switch Turn the hazard warning lamp
switch from "OFF" to "ON"
position.
Page 206 of 1500
SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-206
STEP 2. Check the input signal (by using the pulse check
mode of the monitor).
Check input signals from the transmitter.
To prevent damage to diagnostic tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting diagnostic tool
MB991958.
(1) Connect diagnostic tool MB991958.Refer to "How to
connect SWS monitor P.54B-13."
(2) Operate diagnostic tool MB991958 according to the
procedure below to display "Pulse check."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "Pulse Checking."
(3) Push the transmitter "TRUNK" button.
(4) Check that diagnostic tool MB991958 sounds
Q: When the transmitter "TRUNK" button is turned ON,
does diagnostic tool MB991958 sound?
YES : Go to Step 3.
NO : Refer to Inspection Procedure N-8 "ETACS-ECU
does not receive any signal from the lock, unlock,
trunk or panic switch P.54B-472."
Page 219 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-219
INSPECTION PROCEDURE F-2: Sunroof: Any of the sunroof switch positions is defective.
.
TECHNICAL DESCRIPTION (COMMENT)
The sunroof switch or the sunroof motor assembly
may be defective.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
The sunroof switch may be defective
The sunroof motor assembly may be defective
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
DIAGNOSIS
Required Special Tools:
MB991223: Harness Set
MB991958: diagnostic tool (MUT-III Sub Assembly)
MB991824: Vehicle Communication Interface (V.C.I.)
MB991827: MUT-III USB Cable
MB991910: MUT-III Main Harness A
Check the input signal (by using the pulse check mode of
the monitor).
Check the input signals from the sunroof switch.
To prevent damage to diagnostic tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting diagnostic tool
MB991958.
(1) Connect diagnostic tool MB991958.Refer to "How to
connect SWS monitor P.54B-13."
(2) Operate the diagnostic tool MB991958 according to the
procedure below to display "Pulse check."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "Pulse Checking."
(3) When each function of the sunroof switch is operated
(turned on), check that diagnostic tool MB991958 sounds.
Q: Does diagnostic tool MB991958 sound when the
sunroof switch is operated?
YES : Replace the sunroof motor assembly. Check that the
sunroof works at all positions normally.
NO : Refer to Inspection Procedure M-8 "ETACS-ECU
does not receive any signal from the up, open or
close/down switch P.54B-429."
Page 315 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-315
DIAGNOSIS
Required Special Tools:
MB991223: Harness Set
MB991958: Diagnostic Tool (MUT-III Sub Assembly)
MB991824: Vehicle Communication Interface (V.C.I.)
MB991827: MUT-III USB Cable
MB991910: MUT-III Main Harness A
STEP 1. Check the turn-signal lamps.
Q: Do the turn-signal lamps illuminate normally?
YES : Go to Step 2.
NO : Refer to Inspection Procedure I-1 "Turn-signal lamps
do not flash when the turn-signal lamp switch is
turned on P.54B-310."
STEP 2. Check the input signal (by using the pulse check
mode of the monitor).
Check input signal from the hazard warning lamp switch.
To prevent damage to Diagnostic Tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting Diagnostic Tool
MB991958.
(1) Connect the special tool. Refer to "How to connect SWS
monitor P.54B-13."
(2) Operate Diagnostic Tool MB991958 according to the
procedure below to display "Pulse check."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "Pulse Checking."
(3) Check that Diagnostic Tool MB991958 sounds when the
hazard warning lamp switch is turned from "OFF" to "ON."
Q: Does Diagnostic Tool MB991958 sound when the hazard
warning lamp switch is turned from "OFF" to "ON"?
YES : Replace the ETACS-ECU. Verify that the hazard
warning lamps illuminate normally.
NO : Refer to Inspection Procedure N-2 "ETACS-ECU
does not receive any signal from the hazard warning
lamp switch P.54B-436."
Page 363 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-363
STEP 3. Check the input signal (by using the pulse check
mode of the monitor).
Check the following switches and input signals:
Key reminder switch
Interior lamp loaded signal
Door switches
(1) Operate diagnostic tool MB991958 according to the
procedure below to display "Pulse check."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "Pulse Checking."
(2) Check if diagnostic tool MB991958 sounds or not.
Q: When the key reminder switch, any door switch or
interior lamp is operated, does diagnostic tool
MB991958 sound?
Buzzer of diagnostic tool MB991958 sounds normally. :
Go to Step 4.
Diagnostic tool MB991958 does not sound when the
ignition key is removed and reinserted : Refer to
Inspection Procedure N-1 "ETACS-ECU does not
receive any signal from the key reminder switch
P.54B-432."
When one of the interior lamps is illuminated,
diagnostic tool MB991958 does not sound : Refer to
Inspection Procedure N-9 "ETACS-ECU does not
receive any interior lamp loaded signal P.54B-474."
When one of the doors is opened and closed,
diagnostic tool MB991958 does not sound : Refer to
Inspection Procedure N-3 "ETACS-ECU does not
receive any signal from any of the door switches
P.54B-440." ITEM NAME CONDITION
key reminder switch Remove and reinsert the ignition
key
interior lamp loaded
signalTurn on one of the interior lamps
door switches Open or close one of the doors
Page 373 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-373
STEP 13. Check the wiring harness between rear dome
lamp connector D-07 (terminals 1 and 2) and ETACS-ECU
connector C-219 (terminals 6 and 5).
Q: Is the wiring harness between rear dome lamp
connector D-07 (terminals 1 and 2) and ETACS-ECU
connector C-219 (terminals 6 and 5) in good condition?
YES : Replace the rear dome lamp. Check that the rear
dome lamp illuminates normally.
NO : The wiring harness may be damaged or the
connector(s) may have loose, corroded or damaged
terminals, or terminals pushed back in the connector.
Repair the wiring harness as necessary. Check that
the rear dome lamp illuminates normally.
STEP 14. Check the input signal (by using the pulse check
mode of the monitor).
Check the input signals from the trunk lid latch assembly.
Check whether diagnostic tool MB991958 sounds or not
when the trunk is opened.
(1) Operate diagnostic tool MB991958 according to the
procedure below to display "Pulse checking."
a. Select "Interactive Diagnosis."
b. Select "System Select."
c. Select "SWS."
d. Select "Pulse Checking."
Q: Does diagnostic tool MB991958 sound when the trunk is
opened and closed?
YES : Go to Step 15.
NO : Refer to Inspection Procedure N-7 "ETACS-ECU
does not receive any signal from the trunk lid latch
assembly P.54B-469."
Page 380 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-380
STEP 5. Check the input signal (by using the pulse check
mode of the monitor).
Check the input signals from the following switches:
Key reminder switch
Door switches
Trunk lid latch assembly
(1) Operate diagnostic tool MB991958 according to the
procedure below to display "Pulse check."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "Pulse Checking."
(2) Check if diagnostic tool MB991958 sounds or not.
Q: When the key reminder switch, any door switch, or the
trunk lid is operated, does diagnostic tool MB991958
sound?
Buzzer of diagnostic tool MB991958 sounds normally. :
Replace the ETACS-ECU. Verify that the dome lamp
dimming function works normally.
Diagnostic tool MB991958 does not sound when the
ignition key is removed and reinserted : Refer to
Inspection Procedure N-1 "ETACS-ECU does not
receive a signal from the key reminder switch
P.54B-432."
Diagnostic tool MB991958 does not sound whenever a
door switch is operated : Refer to Inspection Procedure
N-3 "ETACS-ECU does not receive any signal from
any of the door switches P.54B-440."
When the trunk lid is opened and closed, diagnostic
tool MB991958 does not sound. : Refer to Inspection
Procedure N-7 "ETACS-ECU does not receive any
signal from trunk lid latch assembly P.54B-469." ITEM NAME CONDITION
key reminder switch Remove and reinsert the ignition
key
door switches Open or close one of the doors
trunk lid latch assembly Open or close the trunk lid