Page 60 of 1500
SYMPTOM CHART
SIMPLIFIED WIRING SYSTEM (SWS)54B-60
Interior lamp General description concerning the interior lampP.54B-355
The dome lamp do not illuminate and go out
normally.K-1
P.54B-359
The front dome lamp, rear dome lamp or trunk
lamp do not illuminate or go out normally.K-2
P.54B-366
Dome lamp dimming function does not work
normally.K-3
P.54B-376
The ignition key hole illumination lamp does not
illuminate or go out normally.K-4
P.54B-381
The interior lamp automatic shutoff function does
not work normally.K-5
P.54B-389
The door ajar indicator lamps do not illuminate or
go out normallyK-6
P.54B-394
The seat belt warning lamp do not illuminate or go
out normallyK-7
P.54B-398
Can not customize the functions by operating the multi center display . L-1
P.54B-402 SYSTEM SYMPTOM INSPECTION
PROCEDUREREFERENCE
PA G E
Page 62 of 1500

INPUT SIGNAL CHART
SIMPLIFIED WIRING SYSTEM (SWS)54B-62
DIAGNOSTIC TOOL OR VOLTMETER
If a problem is found in the Pulse Check, observe the
table below.
SYMPTOM INSPECTION
PROCEDUREREFERENCE
PA G E
ETACS-ECU does not receive any signal from the key reminder switch. N-1
P.54B-432
ETACS-ECU does not receive any signal from the hazard warning lamp
switch.N-2
P.54B-436
ETACS-ECU does not receive any signal from any of the door switches. N-3
P.54B-440
ETACS-ECU does not receive any signal from the door lock key cylinder
switch.N-4
P.54B-446
ETACS-ECU does not receive any signal from the front door lock actuator. N-5
P.54B-451
ETACS-ECU does not receive any signal from the door lock switch
(incorporated in the power window main switch and front power window
sub switch).N-6
P.54B-460
ETACS-ECU does not receive any signal from the trunk lid latch assembly. N-7
P.54B-469
Transmitter ETACS-ECU does not receive any signal from the lock,
unlock, trunk or panic switch.N-8
P.54B-472
ETACS-ECU does not receive any interior lamp loaded signal. N-9
P.54B-474
Page 94 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-94
NOTE: Also check intermediate connector C-27 for loose, cor-
roded, or damaged terminals, or terminals pushed back in the
connector. If intermediate connector C-27 is damaged, repair or
replace the damaged component(s) as described in GROUP
00E, Harness Connector Inspection P.00E-2.
Q: Is the wiring harness between sunroof motor assembly
connector D-04 (terminal 10) and ETACS-ECU connector
C-218 (terminal 53) in good condition?
YES : Go to Step 10.
NO : The wiring harness may be damaged or the
connector(s) may have loose, corroded or damaged
terminals, or terminals pushed back in the connector.
Repair the wiring harness as necessary. The system
should communicate with the sunroof-ECU normally.
STEP 10. Replace the sunroof motor assembly.
(1) Replace the sunroof motor assembly.
(2) The system should communicate with the sunroof-ECU
normally.
Q: Can the system communicate with the sunroof-ECU?
YES : No action is necessary and testing is complete.
NO : Replace the ETACS-ECU. The system should
communicate with the sunroof-ECU normally.
TONE ALARM
GENERAL DESCRIPTION CONCERNING THE TONE ALARMM1549021000326
The tone alarm functions are as follows. These func-
tions are controlled by relevant ECUs.
FUNCTION CONTROL ECU
Light reminder tone alarm function ETACS-ECU, column switch
Seat belt tone alarm function ETACS-ECU
Door ajar warning buzzer ETACS-ECU
Center display operation tone
display >ETACS-ECU
Turn-signal lamp buzzer ETACS-ECU, column switch
Page 97 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-97
Door ajar warning buzzer
The buzzer is sounded 4 times by the ETACS-ECU to warn the
driver if any door is open when the ignition is switched ON and
the vehicle speed reaches 8 km/h (5 mph) or faster. The buzzer
will continue to sound for 4 times even if the ignition, door sta-
tus, or vehicle speed requirements are not maintained.
NOTE: The warning buzzer can be customized on vehicles
equipped with a multi center display. Refer to P.54B-486.
Multi center display operation tone
center display >
The ETACS-ECU sounds the buzzer when the buzzer signal is
sent from the center display.
Turn-signal lamp buzzer
The ETACS-ECU sounds the buzzer in sync with the turn-sig-
nal lamps or hazard warning lamps.
NOTE: The turn-signal lamp buzzer can be customized on
vehicles equipped with a multi center display (middle grade
type). Refer to P.54B-486.
General circuit diagram for lamp reminder tone alarm function. P.90-111
General circuit diagram for seat belt tone alarm function. P.90-113
Page 106 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-106
INSPECTION PROCEDURE B-4: Tone Alarm: Door ajar Warning Buzzer Function does not Work
Normally.
NOTE: This troubleshooting procedure requires the
use of diagnostic tool MB991958 and SWS monitor
kit MB991813. For details on how to use the SWS
monitor, refer to "How to connect SWS monitor
P.54B-13."
.
CIRCUIT OPERATION
The ETACS-ECU controls the door-ajar warning tone
alarm, based on the signals from the switches and
sensors below.
Ignition switch (IG1): ON
One of the door switches: ON
Vehicle speed signal: 8 km/h (5 mph) or more
.
TECHNICAL DESCRIPTION (COMMENT)
If the door-ajar warning tone alarm does not work,
connector(s), wiring harness in the CAN bus lines,
the combination meter, the ETACS-ECU or the input
signal circuit may be defective.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
Trouble in input signal system
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
The combination meter may be defective
The ETACS-ECU may be defective
Page 107 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-107
DIAGNOSIS
Required Special Tools:
MB991223: Harness Set
MB991958: diagnostic tool (MUT-III Sub Assembly)
MB991824: Vehicle Communication Interface (V.C.I.)
MB991827: MUT-III USB Cable
MB991910: MUT-III Main Harness A
MB991813: SWS Monitor Kit
MB991806: SWS Monitor Cartridge
MB991812: SWS Monitor Harness (For Column-ECU)
MB991822: Test Probe Harness
STEP 1. Check the adjustment function.
Q: Has the door-ajar warning tone alarm function been
enabled by the adjustment function?
YES : Go to Step 2.
NO : Enable the door-ajar warning tone alarm.
STEP 2. Using diagnostic tool MB991958, diagnose the
CAN bus line.
To prevent damage to diagnostic tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting diagnostic tool
MB991958.
(1) Connect diagnostic tool MB991958. Refer to "How to
connect SWS monitor P.54B-13."
(2) Turn the ignition switch to the "ON" position.
(3) Diagnose the CAN bus line.
(4) Turn the ignition switch to the "LOCK" (OFF) position.
Q: Is the CAN bus line found to be normal?
YES : Go to Step 3.
NO : Repair the CAN bus line (Refer to GROUP 54C,
Diagnosis P.54C-13).
Page 111 of 1500
SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-111
STEP 6. Check the input signal (by using the pulse check
mode of the monitor).
Check the following switches and input signals:
Doors switches
(1) Operate diagnostic tool MB991958 according to the
procedure below to display "Pulse check."
a. Select "Interactive Diagnosis."
b. Select "System Select."
c. Select "SWS."
d. Select "Pulse Checking."
(2) Check if diagnostic tool MB991958 sounds or not.
Q: When any door switch is operated, does diagnostic tool
MB991958 sound?
YES : Replace the ETACS-ECU. The door ajar warning
buzzer function should now work normally.
NO : Refer to Inspection Procedure N-3 "ETACS-ECU
does not receive any signal from any of the door
switches P.54B-440." ITEM NAME CONDITION
door switch Open or close one of the doors
Page 117 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-117
STEP 2. Check whether the turn-signal lamps illuminate.
When the turn-signal lamp switch or the hazard warning lamp
switch is operated, check that the turn-signal lamps flash.
Q: Are the turn-signal lamps in good condition?
YES : Go to Step 3.
NO : First, repair the turn-signal lamp(s). Refer to
Inspection Procedure I-3 "One of the turn-signal
lamps does not illuminate P.54B-316."
STEP 3. Use diagnostic tool MB991958 to select "ECU
COMM Check" on the SWS monitor display.
Check the following ECUs:
ETACS-ECU
Column-ECU
To prevent damage to diagnostic tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting diagnostic tool
MB991958. Connect special tool MB991910 before con-
necting special tool MB991812. Be sure to connect special
tool MB991806 after turning on special tool MB991824.
(1) Connect the special tool. Refer to "How to connect SWS
monitor P.54B-13."
(2) Turn the ignition switch to the "ON" position.
(3) Operate diagnostic tool MB991958 according to the
procedure below to display "ECU COMM Check."
1. Select "Interactive Diagnosis."
2. Select "System Select."
3. Select "SWS."
4. Select "SWS MONITOR."
5. Select "ECU COMM Check."
(4) diagnostic tool MB991958 should show "OK" on the "ECU
COMM Check" menus for both the "ETACS ECU" and the
"COLUMN ECU" menus.
Q: Is "OK" displayed for both the "ETACS ECU" and
"COLUMN ECU" menus?
"OK" is displayed for all the items : Go to Step 4.
"NG" is displayed for the "COLUMN ECU" menu : Refer
to Inspection Procedure A-2 "Communication with the
column switch (column-ECU) is not possible
P.54B-68."
"NG" is displayed for the "ETACS ECU" menu : Refer to
Inspection Procedure A-3 "Communication with the
ETACS-ECU is not possible P.54B-74."
"NG" is displayed for all the items : Refer to Inspection
Procedure A-3 "Communication with the ETACS-ECU
is not possible P.54B-74."