INFINITI QX4 2005  Factory Service Manual EC-374Revision: October 2005
DTC P0506 ISC SYSTEM
2005 QX56
DTC P0506 ISC SYSTEMPFP:23781
DescriptionUBS00H6H
NOTE:
If DTC P0506 is displayed with other DTC, first perform the trouble diagnosis for th

Page 1567 of 3419

INFINITI QX4 2005  Factory Service Manual EC-376Revision: October 2005
DTC P0507 ISC SYSTEM
2005 QX56
DTC P0507 ISC SYSTEMPFP:23781
DescriptionUBS00H6L
NOTE:
If DTC P0507 is displayed with other DTC, first perform the trouble diagnosis for th

Page 1569 of 3419

INFINITI QX4 2005  Factory Service Manual EC-378Revision: October 2005
DTC P0550 PSP SENSOR
2005 QX56
DTC P0550 PSP SENSORPFP:49763
Component DescriptionUBS00H6P
Power steering pressure (PSP) sensor is installed to the power
steering high-pre

Page 1571 of 3419

INFINITI QX4 2005  Factory Service Manual EC-380Revision: October 2005
DTC P0550 PSP SENSOR
2005 QX56
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when mea

Page 1572 of 3419

INFINITI QX4 2005  Factory Service Manual DTC P0550 PSP SENSOR
EC-381
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: October 20052005 QX56
2. CHECK PSP SENSOR POWER SUPPLY CIRCUIT
1. Disconnect power steering pressure (PSP) sensor harness con-
nector.
2

Page 1573 of 3419

INFINITI QX4 2005  Factory Service Manual EC-382Revision: October 2005
DTC P0550 PSP SENSOR
2005 QX56
6. CHECK INTERMITTENT INCIDENT
Refer to EC-156, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionUBS00H

Page 1645 of 3419

INFINITI QX4 2005  Factory Service Manual EC-454Revision: October 2005
DTC P1229 SENSOR POWER SUPPLY
2005 QX56
DTC P1229 SENSOR POWER SUPPLYPFP:16119
On Board Diagnosis LogicUBS00H9B
This self-diagnosis has the one trip detection logic.
FAIL

Page 1647 of 3419

INFINITI QX4 2005  Factory Service Manual EC-456Revision: October 2005
DTC P1229 SENSOR POWER SUPPLY
2005 QX56
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals