Page 880 of 4731

REMOTE KEYLESS ENTRY SYSTEM BL-65
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
*1 : In the state that hazard reminder operates.
*2 : In the state that room lamp switch is in “DOOR” position.
Terminals and Reference Value for IPDM E/RAIS004MG
* : In the state that horn reminder operates. 48 PU/W Room lamp output signal
Room lamp is lighting.*
20
Room lamp is being turned off.*
2Battery voltage
49, 52 B Ground — 0
50 PU Door lock actuator (Lock) Door lock / unlock switch
(Free → Lock) 0
→ Battery voltage
51 W/B Passenger and rear doors lock
actuator (Unlock) Door lock / unlock switch
(Free → Unlock) 0
→ Battery voltage
54 W Battery power supply
(power window) — Battery voltage
55 G Battery power supply (Fusible
link) — Battery voltage
58 L Back door switch OFF (Door close) → ON (Door open) 9 → 0
62 W Front door switch (Driver side) OFF (Door close) → ON (Door open) Battery voltage → 0
63 P Rear door switch LH OFF (Door close) → ON (Door open) Battery voltage → 0
TERMI-
NAL WIRE
COLOR ITEM CONDITION VOLTAGE (V)
Approx.
TERMINAL WIRE
COLOR ITEM CONDITION VOLTAGE (V)
Approx.
38 B Ground — 0
48 L CAN H — —
49 R CAN L — —
51 SB Horn relay When door lock is operated using key
fob* (OFF → ON) Battery voltage
→ 0
60 B Ground — 0
Page 881 of 4731

BL-66
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2005 July 2005 FX
CONSULT-II Function (BCM)AIS004MH
CONSULT-II can display each diagnostic item using the diagnostic test modes shown following.
*: Refer to BCS-15, "CAN Communication Inspection Using CONSULT-II (Self-Diagnosis)" .
CONSULT-II INSPECTION PROCEDURE
CAUTION:
If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be
detected in self-diagnosis depending on control unit which carry out CAN communication.
1. Turn ignition switch “OFF”.
2. Connect “CONSULT-II” and “CONSULT-II CONVERTER” to the data link connector.
3. Turn ignition switch “ON”.
4. Touch “START (NISSAN BASED VHCL)”.
5. Touch “BCM”. If “BCM” is not indicated, go to GI-39, "
CONSULT-II Data Link
Connector (DLC) Circuit" .
BCM diagnosis
position Inspection items and diagnosis mode Description
BCM C/U* Self-diagnosis results Carries out the self-diagnosis.
DATA MONI-
TOR CAN diagnosis support
monitor Displays CAN communication system diagnosis, disabled
transmission status, and communication status of each unit
communicated with BCM.
Selection from menu Displays the input data to BCM on real-time basis.
MULTI REMOTE
ENT DATA MONITOR
Displays the input remote keyless entry system data to BCM
on real–time basis.
ACTIVE TEST Gives a drive to a load to check the operation.
WORK SUPPORT Changes the setting for each function.
PBIB1503E
BCIA0029E
BCIA0030E
Page 882 of 4731

REMOTE KEYLESS ENTRY SYSTEM BL-67
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
6. Touch “MULTI REMOTE ENT”.
7. Select diagnosis mode.
“DATA MONITOR”, “ACTIVE TEST” and “WORK SUPPORT”
are available.
CONSULT-II APPLICATION ITEMS
Data Monitor
Active Test
LIIA0194E
BCIA0031E
Monitored Item Description
IGN ON SW Indicates [ON/OFF] condition of ignition switch in ON position.
KEY ON SW Indicates [ON/OFF] condition of key switch.
ACC ON SW Indicates [ON/OFF] condition of ignition switch in ACC position.
KEYLESS LOCK Indicates [ON/OFF] condition of lock signal from key fob.
KEYLWSS UNLOCK Indicates [ON/OFF] condition of unlock signal from key fob.
KEYLESS PANIC Indicates [ON/OFF] condition of panic signal from key fob.
KEYLESS TRUNK This is displayed even when it is not equipped.
DOOR SW-DR Indicates [ON/OFF] condition of front door switch driver side.
DOOR SW-AS Indicates [ON/OFF] condition of door switch passenger side.
DOOR SW-RR Indicates [ON/OFF] condition of front door switch RH.
DOOR SW-RL Indicates [ON/OFF] condition of door switch LH.
BACK DOOR SW Indicates [ON/OFF] condition of back door switch.
TRUNK OPN MNTR This is displayed even when it is not equipped.
CDL LOCK SW Indicates [ON/OFF] condition of lock signal from door lock and unlock switch.
CDL UNLOCK SW Indicates [ON/OFF] condition of unlock signal from door lock and unlock switch.
RKE LCK-UNLOCK Indicates [ON/OFF] condition of simultaneous signal of lock and unlock from key fob.
RKE KEEP UNLK Indicates [ON/OFF] condition of unlock continuousness signal from key fob.
KEY CYL LK-SW Indicates [ON/OFF] condition of lock signal from door key cylinder switch.
KEY CYL UN-SW Indicates [ON/OFF] condition of unlock signal from door key cylinder switch.
Test Item Description
FLASHER This test is able to check right hazard reminder operation. The right hazard lamp turns on when “ON” on CONSULT-II screen is touched.
POWER WINDOW DOWN This test is able to check power window open operation.
The front power windows activate for 10 seconds after “ON” on CONSULT-II screen is touched.
Page 885 of 4731

BL-70
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2005 July 2005 FX
Trouble Diagnosis Chart by SymptomAIS004MJ
NOTE:
Always check the “Work Flow” before troubleshooting. Refer to BL-69, "Work Flow" .
Always check key fob battery before replacing key fob.
Symptom Diagnoses/service procedure Reference
page
All function of remote keyless entry system do not
operate. 1. Check key fob battery and function.
BL-72
2. Replace key fob. Refer to ID Code Entry Procedure.
NOTE:
If the result of key fob function check with CONSULT-II is OK, key
fob is not malfunctioning. BL-84
3. Check remote keyless entry receiver.
BL-79
4. Replace BCM.BCS-16
The new ID of key fob cannot be entered. 1. Check key fob battery and function.
BL-72
2. Check key switch.BL-78
3. Check door switch.BL-74
4. Check ACC switch.BL-73
5. Replace key fob. Refer to ID Code Entry Procedure.
NOTE:
If the result of key fob function check with CONSULT-II is OK, key
fob is not malfunctioning. BL-84
6. Replace BCM.
BCS-16
Door lock or unlock does not function with key fob.
(Power door lock system is “OK”.) 1. Check key fob battery and function.
BL-72
2. Replace key fob. Refer to ID Code Entry Procedure.
NOTE:
If the result of key fob function check with CONSULT-II is OK, key
fob is not malfunctioning. BL-84
3. Replace BCM.
BCS-16
Hazard and horn reminder does not activate prop-
erly when pressing lock or unlock button of key fob. 1. Check hazard and horn reminder mode.*
*: Hazard and horn reminder mode can be changed.
First check the hazard and horn reminder setting. BL-68
2. Check door switch.
BL-74
3. Replace BCM.BCS-16
Hazard reminder does not activate properly when
pressing lock or unlock button of key fob.
(Horn reminder is “OK”.) 1. Check hazard reminder mode.*
*: Hazard reminder mode can be changed.
First check the hazard reminder setting. BL-68
2. Check hazard function with hazard switch.
BL-83
3. Replace BCM.BCS-16
Horn reminder does not activate properly when
pressing lock button of key fob.
(Hazard reminder is “OK”.) 1. Check horn reminder mode.*
*: Horn reminder can be changed.
First check the horn chirp setting. BL-68
2. Check horn function.
BL-83
3. Check IPDM E/R operation.BL-82
4. Replace BCM.BCS-16
Page 886 of 4731

REMOTE KEYLESS ENTRY SYSTEM BL-71
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
Panic alarm (horn and headlamp) does not activate
when panic alarm button is continuously pressed. 1. Check panic alarm mode.*
*: Panic alarm mode can be changed.
First check the panic alarm setting. BL-68
2. Check key fob battery and function.
BL-72
3. Check headlamp function.BL-83
4. Check horn function.BL-83
5. Check IPDM E/R operation.BL-82
6. Check key switch.BL-78
7. Replace key fob. Refer to ID Code Entry Procedure.
NOTE:
If the result of key fob function check with CONSULT-II is OK, key
fob is not malfunctioning. BL-84
8. Replace BCM.
BCS-16
Auto door lock operation does not activate properly.
(All other remote keyless entry system function is
OK.) 1. Check auto door lock operation mode.*
*: Auto door lock operation mode can be changed.
First check the auto door lock operation setting. BL-68
2. Replace BCM.
BCS-16
Keyless power window down (open) operation does
not activate properly.
(All other remote keyless entry system function is
OK.) 1. Check power window down operation mode.*
*: Power window down operation mode can be changed.
First check the power window down setting. BL-68
2. Check power window function.
GW-15
3. Replace BCM.BCS-16
Map lamp and ignition keyhole illumination opera-
tion does not activate properly. 1. Check map lamp and ignition keyhole illumination operation.
BL-832. Check door switch.BL-74
3. Replace BCM.BCS-16
Symptom Diagnoses/service procedure Reference
page
Page 888 of 4731
REMOTE KEYLESS ENTRY SYSTEM BL-73
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
Check ACC SwitchAIS004ML
1. CHECK ACC SWITCH
With CONSULT-II
Check ACC switch (“ACC ON SW”) in “DATA MONITOR” mode with
CONSULT-II.
Without CONSULT-II
Check voltage between BCM connector and ground.
OK or NG
OK >> ACC switch is OK.
NG >> Check the following.
10A fuse [No. 6, located in fuse block (J/B)]
Harness for open or short between BCM and fuse.
Monitor item Condition
ACC SW Ignition switch position is ACC or ON : ON
Ignition switch position is OFF : OFF
PIIA3367E
Item (+)
(–) Condition Voltage (V)
Approx.
Con-
nector Terminal
(Wire color)
BCM M3 11 (LG/R) Ground ACC or ON Battery voltage
OFF 0
PIIA7002E
Page 889 of 4731
BL-74
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2005 July 2005 FX
Check Door SwitchAIS004MM
CHECK DOOR SWITCH (EXCEPT BACK DOOR SWITCH)
1. CHECK DOOR SWITCH INPUT SIGNAL
With CONSULT-II
Check door switches (“DOOR SW-DR”, “DOOR SW-AS”, “DOOR
SW-RL” and “DOOR SW-RR”) in “DATA MONITOR” mode with
CONSULT-II.
Without CONSULT-II
Check voltage between BCM connector and ground.
OK or NG
OK >> Door switch circuit is OK.
NG >> GO TO 2.
Monitor item Condition DATA MONITOR
DOOR SW-DR CLOSE ↓
OPEN: OFF
↓
ON
DOOR SW-AS
DOOR SW-RL
DOOR SW-RR
Item Connector Terminals
(Wire color) Door
condition Voltage (V)
(Approx.)
(+) (-)
Driver side B14 62 (W)
Ground CLOSE
↓
OPEN Battery voltage
↓0
Rear LH 63 (P)
Passenger side M3 12 (P/B)
Rear RH 13 (P/L)
PIIA6469E
PIIA7003E
Page 890 of 4731

REMOTE KEYLESS ENTRY SYSTEM BL-75
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
2. CHECK DOOR SWITCH CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect door switch and BCM connector.
3. Check continuity between door switch connector B26, B36, B46, B206 terminals 1 and BCM connector M3, B14 terminals 62, 12,
63, 13.
4. Check continuity between door switch connector B26, B36, B46, B206 terminal 1 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. CHECK DOOR SWITCH
Check continuity between door switch terminal 1 and ground part of
door switch.
OK or NG
OK >> Check door switch case ground condition.
NG >> Replace door switch. Driver side door
1 (W) – 62 (W) : Continuity should exist.
Passenger side door
1 (SB) – 12 (P/B) : Continuity should exist.
Rear door LH
1 (P) – 63 (P) : Continuity should exist.
Rear door RH
1 (P) – 13 (P/L) : Continuity should exist.
1 (W, SB, P) – Ground : Continuity should not exist.
PIIA7004E
Terminal Door switch condition Continuity
1 Ground part of door switch Pushed No
Released Yes
PIIA3351E