SECURITY AND LOCK
SL
Page
1. General Description ....................................................................................2
2. Door Lock Control System ..........................................................................9
3. Keyless Entry System ...............................................................................14
4. Front Inner Remote ...................................................................................22
5. Front Outer Handle ...................................................................................23
6. Front Door Latch Assembly.......................................................................24
7. Front Door Lock Actuator ..........................................................................25
8. Rear Inner Remote....................................................................................26
9. Rear Outer Handle ....................................................................................27
10. Rear Door Latch Assembly .......................................................................28
11. Rear Door Lock Actuator...........................................................................29
12. Rear Gate Outer Handle ...........................................................................30
13. Rear Gate Latch Assembly .......................................................................31
14. Rear Gate Latch Lock Actuator .................................................................32
15. Front Hood Lock Assembly .......................................................................33
16. Remote Openers .......................................................................................34
17. Ignition Key Lock .......................................................................................35
18. Key Lock Cylinder .....................................................................................36
19. Immobilizer Control Module ......................................................................37
20. Immobilizer Antenna .................................................................................38
21. Keyless Entry Control Module ...................................................................39
22. Double Lock Module .................................................................................40
23. Keyless Transmitter ..................................................................................41
SL-7
SECURITY AND LOCK
General Description
5. KEYLESS ENTRY SYSTEM
B: CAUTION
Before disassembling or reassembling parts,
always disconnect the ground cable from battery.
When repairing radio, control module, etc. which
are provided with memory functions, record the
memory contents before disconnecting the
ground cable from battery. Otherwise, these
contents are cancelled upon disconnection.
Reassemble parts in the reverse order of
disassembly procedure unless otherwise
indicated.
Adjust parts to specifications contained in
this manual if so designated.
Connect the connectors and hoses securely
during reassembly.
After reassembly, ensure all functional parts
operate smoothly.
Airbag system wiring harness is routed near
the electrical parts and switch.
All airbag system wiring harness and
connectors are colored yellow. Do not use
electrical test equipment on these circuits. Be careful not to damage the airbag system
wiring harness when servicing the ignition key
cylinder.
(1) Double lock module (with double
lock)(3) Rear gate latch switch (5) Door switch
(4) Keyless entry control module
(RHD model)
(2) Keyless entry control module
(LHD model)
SL-00055
(2)
(5)
(4)(3)
(1)
SL-9
SECURITY AND LOCK
Door Lock Control System
2. Door Lock Control System
A: WIRING DIAGRAM
1. DOOR LOCK CONTROL
B: INSPECTION
1. SYMPTOM CHART
Symptom Repair order Reference
The door lock control system does
not operate.1. Check the fuse.
System.>
2. Check the power supply and ground circuit for
keyless entry control module (without double lock)
or double lock module (with double lock).
INSPECTION, Door Lock Control
System.>
3. Check the door lock switch and the circuit.
INSPECTION, Door Lock Control
System.>
4. Check the door lock actuator and the circuit.
INSPECTION, Door Lock Control
System.>
The door lock switch does not oper-
ate.Check the door lock switch and the circuit.
INSPECTION, Door Lock Control
System.>
A specific door lock actuator does not
operate.Check the door lock actuator and the circuit.
INSPECTION, Door Lock Control
System.>
The key cylinder lock switch does not
operate. (with double lock)Check the key cylinder lock switch and circuit.
CUIT, INSPECTION, Door Lock
Control System.>
The double lock does not operate.
(with double lock)Check the door lock actuator (double lock) and cir-
cuit.
LOCK) AND CIRCUIT, INSPEC-
TION, Door Lock Control System.>
SL-10
SECURITY AND LOCK
Door Lock Control System
2. CHECK FUSE
3. CHECK POWER SUPPLY AND GROUND CIRCUIT
Step Check Yes No
1 CHECK FUSE.
Remove and visually check the fuse No. 2 (in
the main fuse box).In the fuse blown out? Replace the fuse
with a new one.Check the power
supply and ground
circuit.
POWER SUPPLY
AND GROUND
CIRCUIT,
INSPECTION,
Door Lock Control
System.>
Step Check Yes No
1 CHECK POWER SUPPLY.
1) Disconnect the keyless entry control mod-
ule or double lock module harness connector.
2) Measure the voltage between the harness
connector terminal and chassis ground.
Connector & terminal
Without double lock:
(B176) No. 5, 16 (+) — Chassis ground (
−
):
With double lock:
(B324) No. 7, 8 (+) — Chassis ground (
−):Is the voltage more than 10 V? Go to step 2.Check the harness
for open circuits or
shorts between
the keyless entry
control module or
double lock mod-
ule and the fuse.
2 CHECK GROUND CIRCUIT.
Measure the resistance between the harness
connector terminal and chassis ground.
Connector & terminal
Without double lock:
(B176) No. 6, 14 — Chassis ground:
With double lock:
(B324) No. 9 — Chassis ground:Is the resistance less than 10
Ω?The power supply
and ground circuit
is OK.Repair the har-
ness.
SL-11
SECURITY AND LOCK
Door Lock Control System
4. CHECK DOOR LOCK SWITCH AND CIRCUIT
Step Check Yes No
1 CHECK DOOR LOCK SWITCH CIRCUIT.
1) Disconnect the keyless entry control mod-
ule or double lock module harness connector.
2) Measure the resistance between the har-
ness connector terminal and chassis ground
when moving the door lock switch to LOCK.
Connector & terminal
Without double lock:
(B176) No. 10 — Chassis ground:
With double lock:
(B325) No. 7 — Chassis ground:Is the resistance less than 10
Ω?Go to step 2.Go to step 3.
2 CHECK DOOR LOCK SWITCH CIRCUIT.
Measure the resistance between the harness
connector terminal and chassis ground when
the door lock switch is moved to UNLOCK.
Connector & terminal
Without double lock:
(B176) No. 8 — Chassis ground:
With double lock:
(B325) No. 4 — Chassis ground:Is the resistance less than 10
Ω?The door lock
switch is OK.Go to step 3.
3 CHECK DOOR LOCK SWITCH.
1) Disconnect the door lock switch harness
connector.
2) Measure the resistance between the door
lock switch terminals when moving the door
lock switch to LOCK.
Connector & terminal
LHD model:
(D7) No. 5 — No. 9
RHD model:
(D7) No. 15 — Switch ground:Is the resistance less than 1
Ω?Go to step 4.Replace the door
lock switch.
4 CHECK DOOR LOCK SWITCH.
Measure the resistance between the door lock
switch terminals when moving the door lock
switch to UNLOCK.
Connector & terminal
LHD model:
(D7) No. 5 — No. 8
RHD model:
(D7) No. 16 — Switch ground:Is the resistance less than 1
Ω?Check the harness
for open circuits or
shorts between
the keyless entry
control module or
double lock mod-
ule and the door
lock switch.Replace the door
lock switch.
SL-12
SECURITY AND LOCK
Door Lock Control System
5. CHECK DOOR LOCK ACTUATOR AND CIRCUIT
6. CHECK KEY CYLINDER LOCK SWITCH AND CIRCUIT
Step Check Yes No
1 CHECK OUTPUT SIGNAL.
Measure the voltage between the harness con-
nector terminal of keyless entry control module
or double lock module and chassis ground
when moving the door lock switch to LOCK.
Connector & terminal
Without double lock:
(B176) No. 18 (+) — Chassis ground (
−):
With double lock:
(B324) No. 3 (+) — Chassis ground (
−):Is the voltage more than 10 V? Go to step 2.Replace the key-
less entry control
module or double
lock module.
2 CHECK OUTPUT SIGNAL.
Measure the voltage between the harness con-
nector terminal of keyless entry control module
or double lock module and chassis ground
when moving the door lock switch to UNLOCK.
Connector & terminal
Without double lock:
(B176) No. 17 (+) — Chassis ground (
−):
With double lock:
(B324) No. 5 (+) — Chassis ground (
−):Is the voltage more than 10 V? Go to step 3.Replace the key-
less entry control
module or double
lock module.
3 CHECK DOOR LOCK ACTUATOR.
Check the door lock actuator.
Front door lock actuator:
Rear door lock actuator:
Rear gate latch lock actuator:
for open circuits or
shorts between
the keyless entry
control module or
double lock mod-
ule and the door
lock actuator.Replace the door
lock actuator.
Step Check Yes No
1 CHECK KEY CYLINDER LOCK SWITCH CIR-
CUIT.
1) Disconnect the double lock module har-
ness connector.
2) Measure the resistance between harness
connector terminal and chassis ground when
turning the key cylinder lock switch to lock
position.
Connector & terminal
(B325) No. 2 — Chassis ground:Is the resistance less than 10
Ω?Go to step 2.Go to step 3.
2 CHECK KEY CYLINDER LOCK SWITCH CIR-
CUIT.
Measure the resistance between harness con-
nector terminal and chassis ground when turn-
ing the key cylinder lock switch to unlock
position.
Connector & terminal
(B325) No. 3 — Chassis ground:Is the resistance less than 10
Ω?Key cylinder lock
switch is nor mal.Go to step 3.
SL-14
SECURITY AND LOCK
Keyless Entry System
3. Keyless Entry System
A: WIRING DIAGRAM
B: ELECTRICAL SPECIFICATION
Content Terminal No. Measuring condition
Key warning switch 1 (INPUT) Battery voltage is present when inserting the key into ignition switch.
Registration connector 2 (INPUT) 0 V is present when connecting the registration connector.
Door switch 3 (INPUT) 0 V is present when any door is open.
Power supply 5 Battery voltage is constantly present.
Empty 6 —
Empty 7 —
Door lock switch (Unlock) 8 (INPUT) 0 V is present when the door lock switch is turned to unlock position.
Empty 9 —
Door lock switch (Lock) 10 (INPUT) 0 V is present when the door lock switch is turned to lock position.
Room light/Ignition switch illumina-
tion11 (OUTPUT) 0 V is present when pressing the transmitter OPEN button.
0 V is present when any door is open.
Turn signal light (Left) 12 (OUTPUT)Battery voltage is present when pressing the transmitter OPEN or LOCK
button.
Turn signal light (Right) 13 (OUTPUT)Battery voltage is present when pressing the transmitter OPEN or LOCK
button.
Ground 14 0 V is constantly present.
Power supply (Hazard light) 15 Battery voltage is constantly present.
Power supply 16 Battery voltage is constantly present.
Door, rear gate lock actuator (With-
out double lock) or double lock mod-
ule (With double lock)17 (OUTPUT) Battery voltage is present when pressing the transmitter OPEN button.
Door, rear gate lock actuator (With-
out double lock) or double lock mod-
ule (With double lock)18 (OUTPUT) Battery voltage is present when pressing the transmitter LOCK button.
SL-00036
1 2 3 4 5 6 7 8 9 10
11 12 13 14 15 16 17 18
SL-15
SECURITY AND LOCK
Keyless Entry System
C: INSPECTION
1. SYMPTOM CHART
Symptom Repair order Reference
None of the functions of keyless entry
system operate.1. Check the transmitter battery.
less Entry System.>
2. Check the fuse.
tem.>
3. Check the keyless entry control module power
supply and ground circuit.
INSPECTION, Keyless Entry Sys-
tem.>
4. Replace the keyless entry control module.
The transmitter cannot be registered. 1. Check the transmitter battery.
less Entry System.>
2. Check the registration connector circuit.
INSPECTION, Keyless Entry Sys-
tem.>
3. Check the door lock switch and circuit.
Entry System.>
4. Replace the keyless entry control module.
The door lock or unlock does not
operate.
N
OTE:
If the door lock control system does
not operate when using the door lock
switch, check the door lock control
system.
less Entry System.>
2. Make sure the registration connector is not
connected.Make sure the registration connector
is not connected because keyless
entry system does not operate during
the registration connector connected.
3. Check the key warning switch.
Entry System.>
4. Check the door switch.
Entry System.>
5. Check output signal to double lock module.
(With double lock)
ULE, INSPECTION, Keyless Entry
System.>
6. Replace the keyless entry control module.
The hazard light does not operate. 1. Check the hazard light operation.
Keyless Entry System.>
2. Replace the keyless entry control module.