PARKING, LICENSE PLATE AND TAIL LAMPS
LT-117
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: August 20072004 QX56
CONSULT-II FunctionsEKS007CM
Refer to LT- 1 8 , "CONSULT-II Function (BCM)" in HEADLAMP (FOR USA).
Refer to LT- 2 1 , "
CONSULT-II Function (IPDM E/R)" in HEADLAMP (FOR USA).
Parking, License Plate and/or Tail Lamps Do Not IlluminateEKS007CN
1. CHECK COMBINATION SWITCH INPUT SIGNAL
With CONSULT-II
Select “BCM” on CONSULT-II. With “HEAD LAMP” data monitor,
make sure “LIGHT SW 1ST” turns ON-OFF linked with operation of
lighting switch.
Without CONSULT-II
Refer to LT-100, "
Combination Switch Inspection" .
OK or NG
OK >> GO TO 2.
NG >> Check lighting switch. Refer to LT-100, "
Combination
Switch Inspection" .
2. ACTIVE TEST
With CONSULT-II
1. Select “IPDM E/R” on CONSULT-II, and select “ACTIVE TEST”
on “SELECT DIAG MODE” screen.
2. Select “EXTERNAL LAMPS” on “SELECT TEST ITEM” screen.
3. Touch “TAIL” on "ACTIVE TEST" screen.
4. Make sure parking, license plate and tail lamp operation.
Without CONSULT-II
1. Start auto active test. Refer to PG-23, "
Auto Active Test" .
2. Make sure parking, license plate and tail lamp operation.
OK or NG
OK >> GO TO 3.
NG >> GO TO 4.
3. CHECK IPDM E/R
1. Select “IPDM E/R” on CONSULT-II, and select “DATA MONI-
TOR” on “SELECT DIAG MODE” screen.
2. Make sure “TAIL&CLR REQ” turns ON when lighting switch is in
1ST position.
OK or NG
OK >> Replace IPDM E/R. Refer to PG-29, "Removal and
Installation of IPDM E/R" .
NG >> Replace BCM. Refer to BCS-19, "
Removal and Installa-
tion of BCM" . When lighting switch is in
1ST position: LIGHT SW 1ST ON
SKIA5956E
Parking, license plate and tail lamp should operate
Parking, license plate and tail lamp should operate
WKIA1438E
When lighting switch is in
1ST position: TAIL&CLR REQ ON
SKIA5958E
LT-118
PARKING, LICENSE PLATE AND TAIL LAMPS
Revision: August 20072004 QX56
4. CHECK INPUT SIGNAL
With CONSULT-II
1. Turn ignition switch OFF.
2. Disconnect front combination lamp, license plate lamp and rear combination lamp connectors.
3. Turn ignition switch ON.
4. Select “IPDM E/R” on CONSULT-II, and select “ACTIVE TEST” on “SELECT DIAG MODE” screen.
5. Select “TAIL LAMP” on “SELECT TEST ITEM” screen.
6. Touch “ON” on "ACTIVE TEST" screen.
7. When tail lamp is operating, check voltage between front combination lamp, license plate lamp, rear com-
bination lamp harness connector and ground.
Without CONSULT-II
1. Turn ignition switch OFF.
2. Start auto active test. Refer to PG-23, "
Auto Active Test" .
3. When tail lamp is operating, check voltage between front combination lamp, license plate lamp, rear com-
bination lamp harness connector and ground.
OK or NG
OK >> GO TO 6.
NG >> GO TO 5.
Front combination lamp
(–) Voltage (+)
ConnectorTe r m i n a l
(wire color)
RH E107
3 (R/L) Ground Battery voltage
LH E11
WKIA1900E
License plate lamp
(–) Voltage (+)
ConnectorTe r m i n a l
(wire color)
D703 + (R/L) Ground Battery voltage
WKIA1076E
Rear combination lamp
(–) Voltage (+)
ConnectorTe r m i n a l
(wire color)
RH B130
3 (R/L) Ground Battery voltage
LH B70
WKIA1901E
LT-122
REAR COMBINATION LAMP
Revision: August 20072004 QX56
REAR COMBINATION LAMPPFP:26554
Bulb Replacement (Turn Signal)EKS007CR
NOTE:
The tail/stop lamp bulbs are LEDs and are not serviceable separately.
1. Remove rear combination lamp mounting bolts.
2. Pull rear combination lamp to remove from the vehicle.
3. Turn bulb socket counterclockwise and unlock it.
4. Remove bulb.
Installation is in the reverse order of removal.
Removal and InstallationEKS007CS
1. Remove rear combination lamp mounting bolts.
2. Pull rear combination lamp to remove from the vehicle.
3. Disconnect rear combination lamp connectors.
Installation is in the reverse order of removal.
WKIA1393E
Rear combination lamp
mounting bolts: 2.4 Nm (0.24 kg-m, 21 in-lb)
WKIA1393E
LT-124
TRAILER TOW
Revision: August 20072004 QX56
through 10A fuse (No. 59, located in the fuse and relay box)
to BCM terminal 38, and
through 10A fuse (No. 51, located in the IPDM E/R)
to trailer tow relay 2 terminal 1.
Ground is supplied
to BCM terminal 67 and
to electric brake (pre-wiring) terminal 1
through grounds M57, M61 and M79, and
to IPDM E/R terminals 38 and 59
to trailer tow relay 1 terminal 2
to trailer tow relay 2 terminal 2 and
to trailer connector terminal 2
through grounds E9, E15 and E24.
TRAILER TAIL LAMP OPERATION
The trailer tail lamps are controlled by the trailer tow relay 1.
With the lighting switch in the parking and tail lamp ON (1ST) position, AUTO position (and the auto light sys-
tem is activated) or headlamp ON (2ND) position, power is supplied
through the tail lamp relay, located in the IPDM E/R
through 10A fuse (No. 36, located in the IPDM E/R)
through IPDM E/R terminal 49
to trailer tow relay 1 terminal 1.
When energized, trailer tow relay 1 supplies tail lamp power to trailer connector terminal 6.
TRAILER BRAKE, TURN SIGNAL AND HAZARD LAMP OPERATION
The trailer brake, turn signal and hazard lamps are all controlled by the BCM. When the brake pedal is
depressed, the BCM receives stop lamp switch signal through CAN communication. If the brake pedal is
depressed or either turn signal or the hazard lamps are turned on, the BCM supplies voltage to the trailer
lamps to make them flash or turn on.
Left trailer brake, turn signal and hazard lamp output is supplied
through BCM terminal 52
to trailer connector terminal 1.
Right trailer brake, turn signal and hazard lamp output is supplied
through BCM terminal 51
to trailer connector terminal 4.
TRAILER BRAKE OPERATION
The trailer brake is controlled by the electric brake. The electric brake receives stop lamp switch signal at elec-
tric brake (pre-wiring) terminal 2 when the brake pedal is depressed.
When the brake pedal is depressed, power is supplied by the electric brake
through electric brake (pre-wiring) terminal 3
to trailer connector terminal 3.
TRAILER POWER SUPPLY OPERATION
The trailer power supply is controlled by the trailer tow relay 2.
When the ignition switch is in the ON or START position, power is supplied
through 10A fuse (No. 51, located in the IPDM E/R)
to IPDM E/R terminal 16
to trailer tow relay 2 terminal 1.
When energized, the trailer tow relay 2 supplies power
through trailer tow relay 2 terminals 5 and 7
to trailer connector terminal 5.
LT-130
INTERIOR ROOM LAMP
Revision: August 20072004 QX56
System DescriptionEKS007CY
When room lamp and personal lamp switch is in DOOR position, room lamp and personal lamp ON/OFF is
controlled by timer according to signals from switches including key switch and key lock solenoid, front door
switch LH, unlock signal from keyfob, door lock and unlock switch, front door lock assembly LH (key cylinder
switch), ignition switch, and glass hatch ajar switch.
When room lamp and personal lamp turns ON, there is a gradual brightening over 1 second. When room lamp
and personal lamp turns OFF, there is a gradual dimming over 1 second.
The room lamp and personal lamp timer is controlled by the BCM (body control module).
Room lamp and personal lamp timer control settings can be changed with CONSULT-II.
Ignition keyhole illumination turns ON when front door LH is opened (door switch ON) or key is removed from
key cylinder. Illumination turns OFF when front door LH is closed (door switch OFF).
Step and foot lamp turns ON when front or rear doors are opened (door switch ON). Lamp turns OFF when
front and rear doors are closed (all door switches OFF).
POWER SUPPLY AND GROUND
Power is supplied at all times
through 10A fuse [No. 19, located in the fuse block (J/B)]
to key switch and key lock solenoid terminal 3, and
through 15A fuse [No. 22, located in the fuse block (J/B)]
to BCM terminal 57, and
through 50A fusible link (letter f , located in the fuse and fusible link box)
to BCM terminal 70.
When the key is inserted in key switch and key lock solenoid, power is supplied
through the key switch and key lock solenoid terminal 4
to BCM terminal 37.
With the ignition switch in the ON or START position, power is supplied
through 10A fuse (No. 59, located in the fuse and relay box)
to BCM terminal 38.
Ground is supplied
to BCM terminal 67
through grounds M57, M61 and M79.
When the front door LH is opened, ground is supplied
to BCM terminal 47
through case ground of front door switch LH.
When the front door RH is opened, ground is supplied
to BCM terminal 12
through case ground of front door switch RH.
When the rear door LH is opened, ground is supplied
to BCM terminal 48
through case ground of rear door switch LH.
When the rear door RH is opened, ground is supplied
to BCM terminal 13
through case ground of rear door switch RH.
When the liftgate is opened, ground is supplied
to BCM terminal 43
through back door latch (door ajar switch) terminal 7
through back door latch (door ajar switch) terminal 8
through grounds B7 and B19.
When the glass hatch is opened, ground is supplied
to BCM terminal 42
through case ground of glass hatch ajar switch.
LT-132
INTERIOR ROOM LAMP
Revision: August 20072004 QX56
to key switch and key lock solenoid terminal 3.
Key is removed from ignition key cylinder (key switch OFF), power will not be supplied to BCM terminal 37.
Serial data is supplied
to BCM terminal 22
through main power window and door lock/unlock switch terminal 14.
At the time that front door LH is opened, BCM detects that front door LH is unlocked. It determines that interior
room lamp and map lamp timer operation conditions are met, and turns the interior room lamps ON for 30 sec-
onds.
Key is in ignition key cylinder (key switch ON), power is supplied
through key switch and key lock solenoid terminal 4
to BCM terminal 37.
When key is removed from key switch and key lock solenoid (key switch OFF), power supply to BCM terminal
37 is terminated. BCM detects that key has been removed, determines that interior room lamp and map lamp
timer conditions are met, and turns the interior room lamps ON for 30 seconds.
When front door LH opens → closes, and the key is not inserted in the key switch and key lock solenoid (key
switch OFF), BCM terminal 47 changes between 0V (door open) → 12V (door closed). The BCM determines
that conditions for interior room lamp operation are met and turns the interior room lamp ON for 30 seconds.
Timer control is canceled under the following conditions.
Front door LH is locked [when locked by keyfob, main power window and door lock/unlock switch, or front
door lock assembly LH (key cylinder switch)]
Front door LH is opened (front door switch LH turns ON)
Ignition switch ON.
INTERIOR LAMP BATTERY SAVER CONTROL
If interior lamp is left “ON”, it will not be turned off even when door is closed.
BCM turns off interior lamp automatically to save battery 30 minutes after ignition switch is turned off.
BCM controls interior lamps listed below:
Vanity lamp
Room/map lamp
Cargo lamp
Personal lamp
Step lamps
Puddle lamps
Foot lamps
Ignition keyhole illumination
After lamps turn OFF by the battery saver system, the lamps illuminate again when
signal received from keyfob, or main power window and door lock/unlock switch or front door lock assem-
bly LH (key cylinder switch) is locked or unlocked
door is opened or closed
key is removed from ignition key cylinder (key switch OFF) or inserted in ignition key cylinder (key switch
ON).
Interior lamp battery saver control period can be changed by the function setting of CONSULT-II.
LT-142
INTERIOR ROOM LAMP
Revision: August 20072004 QX56
Terminals and Reference Values for BCMEKS007D1
How to Proceed With Trouble DiagnosisEKS007D2
1. Confirm the symptom or customer complaint.
2. Understand operation description and function description. Refer to LT-130, "
System Description" .
3. Carry out the Preliminary Check. Refer to LT- 1 4 3 , "
Preliminary Check" .
4. Check symptom and repair or replace the cause of malfunction.
5. Does the interior room lamp operate normally? If YES: GO TO 6. If NO: GO TO 4.
6. Inspection End.
Te r m i n a l
No.Wire
colorSignal nameMeasuring condition
Reference value
(Approx.) Ignition
switchOperation or condition
12 R/LFront door switch RH
signalOFFFront door switch
RHON (open) 0V
OFF (closed) Battery voltage
13 GRRear door switch RH
signalOFFRear door switch
RHON (open) 0V
OFF (closed) Battery voltage
22 W/VPower window switch
serial link——
37 B/RKey-in switch detec-
tion signalOFFVehicle key is removed. 0V
Vehicle key is inserted. Battery voltage
38 W/L Ignition power supply ON — Battery voltage
39 W CAN-H — — —
40 R CAN-L — — —
42 GRGlass hatch ajar
switch signalOFFGlass hatch ajar
switchON (open) 0V
OFF (closed) Battery voltage
43 R/BBack door latch (door
ajar switch) signalOFFBack door latch
(door ajar switch)ON (open) 0V
OFF (closed) Battery voltage
47 SBFront door switch LH
signalOFFFront door switch
LHON (open) 0V
OFF (closed) Battery voltage
48 R/YRear door switch LH
signalOFFRear door switch
LHON (open) 0V
OFF (closed) Battery voltage
56 R/GBattery saver output
signalOFF30 minutes after ignition switch is turned
to OFF0V
ON — Battery voltage
57 Y/R Battery power supply OFF — Battery voltage
62 R/W Step lamp signal OFFAny door is open (ON) 0V
All doors are closed (OFF) Battery voltage
63 LInterior room/map
lamp signalOFFEach interior lamp
switch in DOOR
positionAny door
switchON
(open)0V
OFF
(closed)Battery voltage
67 B Ground ON — 0V
70 W/B Battery power supply OFF — Battery voltage
PIIA2344J
LT-144
INTERIOR ROOM LAMP
Revision: August 20072004 QX56
CONSULT-II Function (BCM)EKS007D4
CONSULT-II can display each diagnostic item using the diagnostic test modes shown following.
CONSULT-II OPERATION
CAUTION:
If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be
detected in self-diagnosis depending on control unit which carries out CAN communication.
1. With the ignition switch OFF, connect CONSULT-II and CON-
SULT-II CONVERTER to the data link connector, then turn igni-
tion switch ON.
2. Touch “START (NISSAN BASED VHCL)”.
3. Touch “BCM” on “SELECT SYSTEM” screen.
If “BCM” is not indicated, go to GI-39, "
CONSULT-II Data Link
Connector (DLC) Circuit" .
BCM diagnostic
test itemDiagnostic mode Description
Inspection by partWORK SUPPORTSupports inspections and adjustments. Commands are transmitted to the BCM
for setting the status suitable for required operation, input/output signals are
received from the BCM and received data is displayed.
DATA MONITOR Displays BCM input/output data in real time.
ACTIVE TEST Operation of electrical loads can be checked by sending drive signal to them.
SELF-DIAG RESULTS Displays BCM self-diagnosis results.
CAN DIAG SUPPORT MNTR The result of transmit/receive diagnosis of CAN communication can be read.
ECU PART NUMBER BCM part number can be read.
CONFIGURATION Performs BCM configuration read/write functions.
BBIA0369E
BCIA0029E
BCIA0030E