INFINITI FX35 2004  Service Manual BL-64
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2004 November 2004 FX35/FX45
Terminals and Reference Value for BCMAIS004MF
*1 : In the state that hazard reminder operates.
*2 : In the state that room lamp

Page 872 of 4449

INFINITI FX35 2004  Service Manual REMOTE KEYLESS ENTRY SYSTEM
BL-65
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2004 November 2004 FX35/FX45
Terminals and Reference Value for IPDM E/RAIS004MG
* : In the state that horn reminder operates.
CONS

Page 873 of 4449

INFINITI FX35 2004  Service Manual BL-66
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2004 November 2004 FX35/FX45
5. Touch “BCM”.
If “BCM” is not indicated, go to GI-40, "
CONSULT-II Data Link
Connector (DLC) Circuit" .
6. Touch “M

Page 876 of 4449

INFINITI FX35 2004  Service Manual REMOTE KEYLESS ENTRY SYSTEM
BL-69
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2004 November 2004 FX35/FX45
Trouble Diagnosis Chart by SymptomAIS004MJ
NOTE:
Always check the “Work Flow” before troubleshoo

Page 877 of 4449

INFINITI FX35 2004  Service Manual BL-70
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2004 November 2004 FX35/FX45
Panic alarm (horn and headlamp) does not activate 
when panic alarm button is continuously pressed.1. Check panic alarm mode.*

Page 879 of 4449

INFINITI FX35 2004  Service Manual BL-72
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2004 November 2004 FX35/FX45
Check ACC SwitchAIS004ML
1. CHECK ACC SWITCH
 With CONSULT-II
Check ACC switch (“ACC ON SW”) in “DATA MONITOR” mode wit

Page 880 of 4449

INFINITI FX35 2004  Service Manual REMOTE KEYLESS ENTRY SYSTEM
BL-73
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2004 November 2004 FX35/FX45
Check Door SwitchAIS004MM
CHECK DOOR SWITCH (EXCEPT BACK DOOR SWITCH)
1. CHECK DOOR SWITCH INPUT SIGN

Page 881 of 4449

INFINITI FX35 2004  Service Manual BL-74
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2004 November 2004 FX35/FX45
2. CHECK DOOR SWITCH CIRCUIT 
1. Turn ignition switch OFF.
2. Disconnect door switch and BCM connector.
3. Check continuity bet