Page 2598 of 4449
![INFINITI FX35 2004 Service Manual VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)
EC-1257
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each ter INFINITI FX35 2004 Service Manual VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)
EC-1257
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each ter](/manual-img/42/57021/w960_57021-2597.png)
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)
EC-1257
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureABS00CEG
1. CHECK OVERALL FUNCTION
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Perform “VIAS SOL VALVE” in “ACTIVE TEST” mode with CONSULT-II.
3. Turn VIAS control solenoid valve ON and OFF, and make sure that power valve actuator rod moves.
Without CONSULT-II
1. Lift up the vehicle.
2. Start engine and warm it up to normal operating temperature.
3. Make sure that power valve actuator rod moves when changing
the gear position to N and D alternately.
OK or NG
OK >>INSPECTION END
NG (With CONSULT-II)>>GO TO 2.
NG (Without CONSULT-II)>>GO TO 3.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
29 GYVIAS control solenoid
valve[Engine is running]
Shift lever position is P or N0 - 1.0V
[Engine is running]
Shift lever position is DBATTERY VOLTAGE
(11 - 14V)
[Engine is running]
Engine speed is above 5,000 rpm0 - 1.0V
PBIB0171E
PBIB0172E
Page 2599 of 4449
![INFINITI FX35 2004 Service Manual EC-1258
[VK45DE]
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)
Revision: 2004 November 2004 FX35/FX45
2. CHECK VACUUM EXISTENCE
With CONSULT-II
1. Stop engine and disconnect vacuum hose connected to p INFINITI FX35 2004 Service Manual EC-1258
[VK45DE]
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)
Revision: 2004 November 2004 FX35/FX45
2. CHECK VACUUM EXISTENCE
With CONSULT-II
1. Stop engine and disconnect vacuum hose connected to p](/manual-img/42/57021/w960_57021-2598.png)
EC-1258
[VK45DE]
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)
Revision: 2004 November 2004 FX35/FX45
2. CHECK VACUUM EXISTENCE
With CONSULT-II
1. Stop engine and disconnect vacuum hose connected to power valve actuator.
2. Start engine and let it idle.
3. Perform “VIAS SOL VALVE” in “ACTIVE TEST” mode with CONSULT-II.
4. Turn VIAS control solenoid valve ON and OFF, and check vacuum existence under the following condi-
tions.
OK or NG
OK >> Repair or replace power valve actuator.
NG >> GO TO 4.
3. CHECK VACUUM EXISTENCE
Without CONSULT-II
1. Stop engine and disconnect vacuum hose connected to power valve actuator.
2. Disconnect VIAS control solenoid valve harness connector.
3. Start engine and let it idle.
4. Apply 12V of direct current between VIAS control solenoid valve terminals 1 and 2.
5. Check vacuum existence under the following conditions.
OK or NG
OK >> Repair or replace power valve actuator.
NG >> GO TO 4.
VIAS SOL VALVE Vacuum
ON Should exist.
OFF Should not exist.
PBIB0174E
Condition Vacuum
12V direct current supply Should exist.
No supply Should not exist.
PBIB0175E
Page 2600 of 4449
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)
EC-1259
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
4. CHECK VACUUM HOSE
1. Stop engine.
2. Check hoses and tubes between intake manifold and power
valve actuator for crack, clogging, improper connection or dis-
connection. Refer to EC-677, "
Vacuum Hose Drawing" .
OK or NG
OK >> GO TO 5.
NG >> Repair hoses or tubes.
5. CHECK VACUUM TANK
Refer to EC-1260, "
Component Inspection" .
OK or NG
OK >> GO TO 6.
NG >> Replace vacuum tank.
6. CHECK VIAS CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect VIAS control solenoid valve harness connector.
3. Turn ignition switch ON.
4. Check voltage between terminal 1 and ground with CONSULT-II
or tester.
OK or NG
OK >> GO TO 8.
NG >> GO TO 7.
SEF109L
PBIB1498E
Voltage: Battery voltage
PBIB0173E
Page 2601 of 4449
![INFINITI FX35 2004 Service Manual EC-1260
[VK45DE]
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)
Revision: 2004 November 2004 FX35/FX45
7. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E211, M41
Harness connector INFINITI FX35 2004 Service Manual EC-1260
[VK45DE]
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)
Revision: 2004 November 2004 FX35/FX45
7. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E211, M41
Harness connector](/manual-img/42/57021/w960_57021-2600.png)
EC-1260
[VK45DE]
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)
Revision: 2004 November 2004 FX35/FX45
7. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E211, M41
Harness connectors M82, F102
IPDM E/R connector E7
10A fuse
Harness continuity between IPDM E/R and VIAS control solenoid valve
>> Repair open circuit or short to ground or short to power in harness or connectors.
8. CHECK VIAS CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 29 and VIAS control solenoid valve terminal 2.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 9.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
9. CHECK VIAS CONTROL SOLENOID VALVE
Refer to EC-1260, "
Component Inspection" .
OK or NG
OK >> GO TO 10.
NG >> Replace VIAS control solenoid valve.
10. CHECK INTERMITTENT INCIDENT
Refer to EC-784, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionABS00CEH
VIAS CONTROL SOLENOID VALVE
With CONSULT-II
1. Reconnect harness connectors disconnected.
2. Turn ignition switch ON.
3. Perform “VIAS SOL VALVE” in “ACTIVE TEST” mode.
4. Check air passage continuity and operation delay time under the
following conditions.
Operation takes less than 1 second.Continuity should exist.
Condition
VIAS SOL VALVEAir passage continuity
between A and BAir passage continuity
between A and C
ON Yes No
OFF No Yes
PBIB0177E
Page 2602 of 4449
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)
EC-1261
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
With GST
Check air passage continuity and operation delay time under the fol-
lowing conditions.
Operation takes less than 1 second.
VACUUM TANK
1. Disconnect vacuum hose connected to vacuum tank.
2. Connect a vacuum pump to the port A of vacuum tank.
3. Apply vacuum and make sure that vacuum exists at the port B.
Removal and InstallationABS00CEI
VIAS CONTROL SOLENOID VALVE
Refer to EM-174, "INTAKE MANIFOLD" .
ConditionAir passage continuity
between A and BAir passage continuity
between A and C
12V direct current supply
between terminals 1 and 2Ye s N o
No supply No Yes
MEC488B
PBIB0846E
Page 2615 of 4449
EC-1274
[VK45DE]
INJECTOR CIRCUIT
Revision: 2004 November 2004 FX35/FX45
INJECTOR CIRCUITPFP:16600
Component DescriptionABS00CEO
The fuel injector is a small, precise solenoid valve. When the ECM
supplies a ground to the injector circuit, the coil in the injector is
energized. The energized coil pulls the ball valve back and allows
fuel to flow through the injector into the intake manifold. The amount
of fuel injected depends upon the injection pulse duration. Pulse
duration is the length of time the injector remains open. The ECM
controls the injection pulse duration based on engine fuel needs.
CONSULT-II Reference Value in Data Monitor ModeABS00CEP
Specification data are reference values.
SEF375Z
MONITOR ITEM CONDITION SPECIFICATION
B/FUEL SCHDL See EC-780, "
TROUBLE DIAGNOSIS - SPECIFICATION VALUE" .
INJ PULSE-B1
INJ PULSE-B2
Engine: After warming up
Air conditioner switch: OFF
Shift lever: N
No loadIdle 2.3 - 2.9 msec
2,000 rpm 2.3 - 2.9 msec
Page 2621 of 4449
![INFINITI FX35 2004 Service Manual EC-1280
[VK45DE]
FUEL PUMP CIRCUIT
Revision: 2004 November 2004 FX35/FX45
FUEL PUMP CIRCUITPFP:17042
DescriptionABS00CEU
SYSTEM DESCRIPTION
*: ECM determines the start signal status by the signals of INFINITI FX35 2004 Service Manual EC-1280
[VK45DE]
FUEL PUMP CIRCUIT
Revision: 2004 November 2004 FX35/FX45
FUEL PUMP CIRCUITPFP:17042
DescriptionABS00CEU
SYSTEM DESCRIPTION
*: ECM determines the start signal status by the signals of](/manual-img/42/57021/w960_57021-2620.png)
EC-1280
[VK45DE]
FUEL PUMP CIRCUIT
Revision: 2004 November 2004 FX35/FX45
FUEL PUMP CIRCUITPFP:17042
DescriptionABS00CEU
SYSTEM DESCRIPTION
*: ECM determines the start signal status by the signals of engine speed and battery voltage.
The ECM activates the fuel pump for several seconds after the ignition switch is turned ON to improve engine
startability. If the ECM receives a engine speed signal from the camshaft position sensor (PHASE), it knows
that the engine is rotating, and causes the pump to operate. If the engine speed signal is not received when
the ignition switch is ON, the engine stalls. The ECM stops pump operation and prevents battery discharging,
thereby improving safety. The ECM does not directly drive the fuel pump. It controls the ON/OFF fuel pump
relay, which in turn controls the fuel pump.
COMPONENT DESCRIPTION
A turbine type design fuel pump is used in the fuel tank.
CONSULT-II Reference Value in Data Monitor ModeABS00CEV
Specification data are reference values.
Sensor Input signal to ECM ECM Function Actuator
Crankshaft position sensor (POS)
Camshaft position sensor (PHASE)Engine speed*
Fuel pump control Fuel pump relay
Battery Battery voltage*
Condition Fuel pump operation
Ignition switch is turned to ON Operates for 1 second.
Engine running and crankingOperates.
When engine is stoppedStops in 1.5 seconds.
Except as shown aboveSto ps.
PBIB1508E
MONITOR ITEM CONDITION SPECIFICATION
FUEL PUMP RLY
For 1 second after turning ignition switch ON
Engine running or crankingON
Except above conditions OFF
Page 2628 of 4449
REFRIGERANT PRESSURE SENSOR
EC-1287
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
REFRIGERANT PRESSURE SENSORPFP:92136
Component DescriptionABS00CF0
The refrigerant pressure sensor is installed at the condenser of the
air conditioner system. The sensor uses an electrostatic volume
pressure transducer to convert refrigerant pressure to voltage. The
voltage signal is sent to ECM, and ECM controls cooling fan system.
PBIB1492E
PBIB2657E