INFINITI FX35 2004  Service Manual EC-960
[VK45DE]
DTC P0335 CKP SENSOR (POS)
Revision: 2004 November 2004 FX35/FX45
DTC P0335 CKP SENSOR (POS)PFP:23731
Component DescriptionABS00C4Y
The crankshaft position sensor (POS) is located on t

Page 2303 of 4449

INFINITI FX35 2004  Service Manual EC-962
[VK45DE]
DTC P0335 CKP SENSOR (POS)
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by

Page 2304 of 4449

INFINITI FX35 2004  Service Manual DTC P0335 CKP SENSOR (POS)
EC-963
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
2. CHECK CRANKSHAFT POSITION (CKP) SENSOR (POS) POWER SUPPLY CIRCUIT
1. Disconnect crankshaf

Page 2307 of 4449

INFINITI FX35 2004  Service Manual EC-966
[VK45DE]
DTC P0340 CAMSHAFT POSITION (CMP) SENSOR (PHASE)
Revision: 2004 November 2004 FX35/FX45
DTC P0340 CAMSHAFT POSITION (CMP) SENSOR (PHASE)PFP:23731
Component DescriptionABS00C56
The cams

Page 2309 of 4449

INFINITI FX35 2004  Service Manual EC-968
[VK45DE]
DTC P0340 CAMSHAFT POSITION (CMP) SENSOR (PHASE)
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
Pulse

Page 2310 of 4449

INFINITI FX35 2004  Service Manual DTC P0340 CAMSHAFT POSITION (CMP) SENSOR (PHASE)
EC-969
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
3. CHECK CAMSHAFT POSITION (CMP) SENSOR (PHASE) POWER SUPPLY CIRCUIT
1

Page 2312 of 4449

INFINITI FX35 2004  Service Manual DTC P0420, P0430 THREE WAY CATALYST FUNCTION
EC-971
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0420, P0430 THREE WAY CATALYST FUNCTIONPFP:20905
On Board Diagnosis L

Page 2313 of 4449

INFINITI FX35 2004  Service Manual EC-972
[VK45DE]
DTC P0420, P0430 THREE WAY CATALYST FUNCTION
Revision: 2004 November 2004 FX35/FX45
8. Select “DTC & SRT CONFIRMATION” then “SRT WORK SUP-
PORT” mode with CONSULT-II.
9. Rev en