NISSAN X-TRAIL 2003  Service Repair Manual ATC-150
REFRIGERANT LINES
 
Inspection
Clutch disc
If the contact surface shows signs of damage due to excessive heat,
replace clutch disc and pulley.
Pulley
Check the appearance of the pulley assembl

Page 3547 of 4179

NISSAN X-TRAIL 2003  Service Repair Manual REFRIGERANT LINES
ATC-151
C
D
E
F
G
H
I
K
L
MA
B
AT C
 
4. Install clutch disc on drive shaft, together with original shim(s).
Press clutch disc down by hand.
5. Using the holder to prevent clutch dis

Page 3549 of 4179

NISSAN X-TRAIL 2003  Service Repair Manual REFRIGERANT LINES
ATC-153
C
D
E
F
G
H
I
K
L
MA
B
AT C
 
6. Check clearance around the entire periphery of clutch disc.
If the specified clearance is not obtained, replace adjusting
spacer and readjust

Page 3551 of 4179

NISSAN X-TRAIL 2003  Service Repair Manual REFRIGERANT LINES
ATC-155
C
D
E
F
G
H
I
K
L
MA
B
AT C
 
INSTALLATION
Installation is basically the reverse order of removal.
CAUTION:
Replace the O-ring of high-pressure flexible hose with a new one,

Page 3552 of 4179

NISSAN X-TRAIL 2003  Service Repair Manual ATC-156
REFRIGERANT LINES
 
5. Disconnect refrigerant pressure sensor connector (With QR
engine) or dual-pressure switch connector (With YD engine).
6. Remove front grille and radiator mounting bracke

Page 3556 of 4179

NISSAN X-TRAIL 2003  Service Repair Manual ATC-160
REFRIGERANT LINES
 
Checking for Refrigerant LeaksEJS000VJ
Perform a visual inspection of all refrigeration parts, fittings, hoses and components for signs of A/C lubricant
leakage, damage and

Page 3557 of 4179

NISSAN X-TRAIL 2003  Service Repair Manual REFRIGERANT LINES
ATC-161
C
D
E
F
G
H
I
K
L
MA
B
AT C
 
Electronic Refrigerant Leak DetectorEJS000VM
PRECAUTIONS FOR HANDLING LEAK DETECTOR
When performing a refrigerant leak check, use an A/C leak de

Page 3558 of 4179

NISSAN X-TRAIL 2003  Service Repair Manual ATC-162
REFRIGERANT LINES
 
3. Check if the A/C refrigerant pressure is at least 345 kPa (3.45 bar, 3.52 kg/cm2 , 50 psi) above 16°C
(61°F). If less than specification, recover/evacuate and recharge