TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT
EC-123
[QR (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENTPFP:00006
DescriptionEBS010M6
Intermittent incidents (I/I) may occur. In many cases, the malfunction resolves itself (the part or circuit function
returns to normal without intervention). It is important to realize that the symptoms described in the customer's
complaint often do not recur on (1st trip) DTC visits. Realize also that the most frequent cause of I/I occur-
rences is poor electrical connections. Because of this, the conditions under which the incident occurred may
not be clear. Therefore, circuit checks made as part of the standard diagnostic procedure may not indicate the
specific malfunctioning area.
Common I/I Report Situations
Diagnostic ProcedureEBS010M7
1. INSPECTION START
Erase (1st trip) DTCs. Refer to EC-63, "
HOW TO ERASE EMISSION-RELATED DIAGNOSTIC INFORMA-
TION" .
>> GO TO 2.
2. CHECK GROUND TERMINALS
Check ground terminals for corroding or loose connection.
Refer to GI-23, "
How to Perform Efficient Diagnosis for an Electrical Incident" , “Incident Simulation Tests”,
“Ground Inspection”.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace.
3. SEARCH FOR ELECTRICAL INCIDENT
Perform GI-23, "
How to Perform Efficient Diagnosis for an Electrical Incident" , “Incident Simulation Tests”.
OK or NG
OK >>INSPECTION END
NG >> Repair or replace.
STEP in Work Flow Situation
II The CONSULT-II is used. The SELF-DIAG RESULTS screen shows time data other than [0] or [1t].
III The symptom described by the customer does not recur.
IV (1st trip) DTC does not appear during the DTC Confirmation Procedure.
VI The Diagnostic Procedure for PXXXX does not indicate the malfunctioning area.
POWER SUPPLY AND GROUND CIRCUIT
EC-125
[QR (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureEBS010M9
1. INSPECTION START
Start engine.
Is engine running?
Ye s o r N o
Ye s > > G O T O 11 .
No >> GO TO 2.
2. CHECK ECM POWER SUPPLY CIRCUIT-I
1. Turn ignition switch OFF and then ON.
2. Check voltage between ECM terminal 109 and ground with
CONSULT-II or tester.
OK or NG
OK >> GO TO 4.
NG >> GO TO 3.
3. DETECT MALFUNCTIONING PART
Check the following.
Fuse block (J/B) connector M1
10A fuse
Harness for open or short between ECM and fuse
>> Repair open circuit or short to ground or short to power in harness or connectors.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
1 B ECM ground[Engine is running]
Idle speedBody ground
109 B/R Ignition switch[Ignition switch: OFF]0V
[Ignition switch: ON]BATTERY VOLTAGE
(11 - 14V)
111 G / WECM relay
(Self shut-off)[Engine is running]
[Ignition switch: OFF]
For a few seconds after turning ignition switch
OFF0 - 1.0V
[Ignition switch: OFF]
More than a few seconds passed turning ignition
switch OFFBATTERY VOLTAGE
(11 - 14V)
11 5
11 6B
BECM ground[Engine is running]
Idle speedBody ground
11 9
120SB
GYPower supply for
ECM[Ignition switch: ON]BATTERY VOLTAGE
(11 - 14V)
Voltage: Battery voltage
MBIB0015E
EC-136
[QR (WITH EURO-OBD)]
DTC P0011 IVT CONTROL
On Board Diagnosis LogicEBS010MI
The MI will not light up for this diagnosis.
FAIL-SAFE MODE
ECM enters in fail-safe mode when the malfunction is detected.
DTC Confirmation ProcedureEBS010MJ
CAUTION:
Always drive at a safe speed.
NOTE:
If DTC P0011 is displayed with DTC P1111, first perform trouble diagnosis for DTC P1111. See EC-
286 .
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait
at least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is between 10V and 16V at
idle.
WITH CONSULT-II
1. Turn ignition switch ON and select “DATA MONITOR” mode with
CONSULT-II.
2. Start engine and warm it up to the normal operating tempera-
ture.
3. Maintain the following conditions for at least 6 consecutive sec-
onds.
Hold the accelerator pedal as steady as possible.
4. Let engine idle for 10 seconds.
5. If the 1st trip DTC is detected, go to EC-137, "
Diagnostic Procedure" .
If the 1st trip DTC is not detected, go to next step.
6. Maintain the following conditions for at least 20 consecutive seconds.
7. If 1st trip DTC is detected, go to EC-137, "
Diagnostic Procedure" .
WITH GST
Follow the procedure “WITH CONSULT-II” above.
DTC No.Trouble diagnosis
nameDetecting condition Possible cause
P0011
0011Intake valve timing
control performanceThere is a gap between angle of target and
phase-control angle degree.
Crankshaft position sensor (POS)
Camshaft position sensor (PHASE)
Accumulation of debris to the signal pick-up
portion of the camshaft
Detected items Engine operating condition in fail-safe mode
Intake valve timing control The signal is not energized to the solenoid valve and the valve control does not function
ENG SPEED 1,200 - 2,000 rpm (A constant rotation is maintained.)
COOLANT TEMPS 60 - 120°C (176 - 194°F)
Selector leverA/T: P or N position
M/T: Neutral position
ENG SPEED 1,700 - 3,175 rpm (A constant rotation is maintained.)
COOLANT TEMPS 70 - 105°C (176 - 194°F)
Selector lever 1st or 2nd position
Driving location uphillDriving vehicle uphill
(Increased engine load will help maintain the driving
conditions required for this test.)
SEF174Y
EC-138
[QR (WITH EURO-OBD)]
DTC P0031, P0032 HO2S1 HEATER
DTC P0031, P0032 HO2S1 HEATERPFP:22690
DescriptionEBS010ML
SYSTEM DESCRIPTION
The ECM performs ON/OFF duty control of the heated oxygen sensor 1 heater corresponding to the engine
speed and engine coolant temperature. The duty percent varies with engine coolant temperature when engine
is started.
OPERATION
CONSULT-II Reference Value in Data Monitor ModeEBS010MM
Specification data are reference values.
On Board Diagnosis LogicEBS010MN
DTC Confirmation ProcedureEBS010MO
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is between 10.5V and 16V at
idle.
WITH CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
Sensor Input Signal to ECM ECM function Actuator
Camshaft position sensor (PHASE)
Crankshaft position sensor (POS)Engine speed
Heated oxygen sensor 1
heater controlHeated oxygen sensor 1
heater
Engine coolant temperature sensor Engine coolant temperature
Engine speed rpm Heated oxygen sensor 1 heater
Above 3,600 OFF
Below 3,600 ON
MONITOR ITEM CONDITION SPECIFICATION
HO2S1 HTR (B1)
Engine: After warming up
Engine speed: Below 3,600 rpmON
Engine speed: Above 3,600 rpm OFF
DTC No.Trouble diagnosis
nameDTC detecting condition Possible cause
P0031
0031Heated oxygen
sensor 1 heater
control circuit lowThe current amperage in the heated oxygen
sensor 1 heater circuit is out of the normal
range.
(An excessively low voltage signal is sent to
ECM through the heated oxygen sensor 1
heater.)
Harness or connectors
(The heated oxygen sensor 1 heater circuit is
open or shorted.)
Heater oxygen sensor 1 heater
P0032
0032Heated oxygen
sensor 1 heater
control circuit highThe current amperage in the heated oxygen
sensor 1 heater circuit is out of the normal
range.
(An excessively high voltage signal is sent to
ECM through the heated oxygen sensor 1
heater.)
Harness or connectors
(The heated oxygen sensor 1 heater circuit is
shorted.)
Heater oxygen sensor 1 heater
DTC P0031, P0032 HO2S1 HEATER
EC-139
[QR (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
3. Turn ignition switch ON and select “DATA MONITOR” mode with
CONSULT-II.
4. Start engine and run it for at least 6 seconds at idle speed.
5. If 1st trip DTC is detected, go to EC-141, "
Diagnostic Procedure"
.
WITH GST
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and run it for at least 6 seconds at idle speed.
4. Turn ignition switch OFF and wait at least 10 seconds.
5. Start engine and run it for at least 6 seconds at idle speed.
6. Select MODE 3 with GST.
7. If DTC is detected, go to EC-141, "
Diagnostic Procedure" .
When using GST, DTC Confirmation Procedure should be performed twice as much as when using
CONSULT-II because GST cannot display MODE 7 (1st trip DTC) concerning this diagnosis. There-
fore, using CONSULT-II is recommended.
SEF174Y
DTC P0037, P0038 HO2S2 HEATER
EC-145
[QR (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
WITH CONSULT-II
1. Turn ignition switch ON and select “DATA MONITOR” mode with
CONSULT-II.
2. Start engine and warm it up to the normal operating tempera-
ture.
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Start engine and keep the engine speed between 3,500 and
4,000 rpm for at least 1 minute under no load.
5. Let engine idle for 1 minute.
6. If 1st trip DTC is detected, go to EC-147, "
Diagnostic Procedure"
.
WITH GST
1. Start engine and warm it up the normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.
4. Let engine idle for 1 minute.
5. Turn ignition switch OFF and wait at least 10 seconds.
6. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.
7. Let engine idle for 1 minute.
8. Select MODE 3 with GST.
9. If DTC is detected, go to EC-147, "
Diagnostic Procedure" .
When using GST, DTC Confirmation Procedure should be performed twice as much as when using
CONSULT-II because GST cannot display MODE 7 (1st trip DTC) concerning this diagnosis. There-
fore, using CONSULT-II is recommended.
SEF058YSEF174Y
EC-150
[QR (WITH EURO-OBD)]
DTC P0102, P0103 MAF SENSOR
2. Select “DATA MONITOR” mode with CONSULT-II.
3. Start engine and wait at least 5 seconds.
4. If DTC is detected, go to EC-152, "
Diagnostic Procedure" .
With GST
Follow the procedure “With CONSULT-II” above.
PROCEDURE FOR DTC P0103
With CONSULT-II
1. Turn ignition switch ON.
2. Select “DATA MONITOR” mode with CONSULT-II.
3. Wait at least 5 seconds.
4. If DTC is detected, go to EC-152, "
Diagnostic Procedure" .
If DTC is not detected, go to next step.
5. Start engine and wait at least 5 seconds.
6. If DTC is detected, go to EC-152, "
Diagnostic Procedure" .
With GST
Follow the procedure “With CONSULT-II” above.
SEF058Y
SEF058Y
EC-152
[QR (WITH EURO-OBD)]
DTC P0102, P0103 MAF SENSOR
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureEBS010N6
1. INSPECTION START
Which malfunction (P0102 or P0103) is duplicated?
P0102 or P0103
P0102 >> GO TO 2.
P0103 >> GO TO 3.
2. CHECK INTAKE SYSTEM
Check the following for connection.
Air duct
Va c u u m h o s e s
Intake air passage between air duct to intake manifold
OK or NG
OK >> GO TO 3.
NG >> Reconnect the parts.
TERMI-
NAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
50 OR Mass air flow sensor[Engine is running]
Warm-up condition
Idle speed0.7 - 1.1V (QR20DE)
0.8 - 1.2V (QR25DE)
[Engine is running]
Warm-up condition
Engine speed is 2,500 rpm1.4 - 1.9V (QR20DE)
1.6 - 1.9V (QR25DE)
67 B/PSensor ground
(Mass air flow sensor)[Engine is running]
Warm-up condition
Idle speedApproximately 0V