ATC-52
TROUBLE DIAGNOSIS
AUXILIARY MECHANISM: TEMPERATURE SETTING TRIMMER
The trimmer compensates for differences in range of ±3°C between temperature setting (displayed digitally)
and temperature felt by customer.
Operating procedures for this trimmer are as follows:
1. Begin Self-diagnosis STEP-5 mode. Refer to AT C - 4 6 , "
Self-diagnosis Function" .
2. Press fan control switch (UP) to set system in auxiliary mode.
3. Display shows “61” in auxiliary mechanism. It takes approximately 3 seconds to enable setting operation.
4. Press temperature control switch (driver side) as desired. Temperature will change at a rate of 0.5°C each
time a switch is pressed.
CAUTION:
A decimal point is not indicated during a setup of temperature compensation.
When battery cable is disconnected or battery voltage below 10 V, trimmer operation is canceled. Temperature
set becomes that of initial condition, i.e. 0°C.
PJIA0014E
TROUBLE DIAGNOSIS
ATC-53
C
D
E
F
G
H
I
K
L
MA
B
AT C
AUXILIARY MECHANISM: FOOT POSITION SETTING TRIMMER
Wind distribution ratio in FOOT mode can be set.
Operating procedures for this trimmer are as follows:
1. Begin self-diagnosis STEP-5 mode. Refer to AT C - 4 6 , "
Self-diagnosis Function" .
2. Press fan control switch (UP) to set system in auxiliary mode.
3. Display shows “61” in auxiliary mechanism. It takes approximately 3 seconds to enable setting operation.
4. Press mode switch as desired.
When battery cable is disconnected or battery voltage below 10 V, trimmer operation is canceled. Air distribu-
tion ratio set becomes that of initial condition.
AUXILIARY MECHANISM: INLET PORT MEMORY FUNCTION
When ignition switch is turned from OFF to ON, inlet port memory function at manual mode can be set.
Operating procedures for this trimmer are as follows:
1. Begin self-diagnosis STEP-5 mode. Refer to AT C - 4 6 , "
Self-diagnosis Function" .
2. Press fan control switch (UP) to set system in auxiliary mode.
3. Display shows “61” in auxiliary mechanism.
4. Press the intake switch as desired.
When battery cable is disconnected or battery voltage below 10 V, memory function is canceled. Memory func-
tion set becomes that of initial condition.
SJIA1580E
LED status of intake switch Setting status
Setting changeover
method
REC FRE REC FRE
ON OFFManual REC status is memorized.
(Initial setting)AUTO control (Initial setting)
Intake SW: ON ON ON Manual REC status is memorized. Manual FRE status is memorized.
OFF ON AUTO control Manual FRE status is memorized.
OFF OFF AUTO control AUTO control