DI-56
WARNING CHIME
WARNING CHIMEPFP:24814
System DescriptionBKS001SX
POWER SUPPLY AND GROUND CIRCUIT
Power is supplied at all times
through 50A fusible link (letter M , located in the fuse and fusible link block)
to BCM terminal 55,
through 15A fuse [No. 17, located in the fuse block (J/B)]
to combination meter terminal 7
to key switch terminal 1 (without Intelligent Key), and
to BCM terminal 42,
through 15A fuse [No. 18, located in the fuse block (J/B)] (with Intelligent Key)
to key switch terminal 3, and
to ignition knob switch terminal 7,
through 10A fuse [No. 19, located in the fuse block (J/B)]
to unified meter and A/C amp. terminal 21.
When ignition switch ON or START position, power is supplied
through 10A fuse [No. 1, located in the fuse block (J/B)]
to BCM terminal 38,
through 10A fuse [No. 12, located in the fuse block (J/B)]
to unified meter and A/C amp. terminal 22,
through 10A fuse [No. 14, located in the fuse block (J/B)]
to combination meter terminal 8.
Ground is supplied
to BCM terminal 52
to unified meter and A/C amp. terminals 29 and 30, and
to combination meter terminals 10, 11 and 12
through grounds M71 and M72.
NOTE:
When ignition key warning chime and light warning chime should be performed at the same time, the priorities
for each chime are the following.
1. Light warning chime
2. Ignition key warning chime
IGNITION KEY WARNING CHIME (WITHOUT INTELLIGENT KEY)
With the key inserted into the ignition switch, and the ignition switch OFF or ACC, when driver's door open, the
warning chime will sound.
Power is supplied
through key switch terminal 4
to BCM terminal 37.
Ground is supplied
to BCM terminal 62
through front door switch (driver side) terminal 2.
Front door switch (driver side) is case grounded.
BCM detects key inserted into the ignition switch, and sends key warning signal to unified meter and A/C amp.
with CAN communication line. Unified meter and A/C amp. sends key warning signal to combination meter
with communication line between unified meter and A/C amp. and combination meter.
When combination meter receives key warning signal, it sounds warning chime.
WARNING CHIME
DI-57
C
D
E
F
G
H
I
J
L
MA
B
DI
IGNITION KEY WARNING CHIME (WITH INTELLIGENT KEY)
When Mechanical Key Is Used
With the key inserted into the ignition switch, and the ignition switch LOCK or ACC, when driver's door open,
the warning chime will sound.
Power is supplied
through ignition knob switch, key switch and key lock solenoid terminal 8
to BCM terminal 37.
Ground is supplied
to BCM terminal 62
through front door switch (driver side) terminal 2.
Front door switch (driver side) is case grounded.
BCM detects key inserted into the ignition switch, and sends key warning signal to unified meter and A/C amp.
with CAN communication line. Unified meter and A/C amp. sends key warning signal to combination meter
with communication line between unified meter and A/C amp. and combination meter.
When combination meter receives key warning signal, it sounds warning chime.
When Intelligent Key Is Carried With The Driver
With the ignition knob is in LOCK (push switch ON) or ACC, when driver's door open, the warning chime will
sound.
Power is supplied
through ignition knob switch, key switch and key lock solenoid terminal 2
to Intelligent Key unit terminal 27.
Ground is supplied
to BCM terminal 62
through front door switch (driver side) terminal 2.
Front door switch (driver side) is case grounded.
BCM sends front door switch signal to Intelligent Key unit with CAN communication line.
Intelligent Key unit detects ignition knob return is forgotten, and sends key warning signal to unified meter and
A/C amp. with CAN communication line. Unified meter and A/C amp. sends key warning signal to combination
meter with communication line between unified meter and A/C amp. and combination meter.
When combination meter receives key warning signal, it sounds warning chime.
LIGHT WARNING CHIME
With the key removed from the ignition switch or with the ignition knob is in LOCK (push switch OFF) [with
Intelligent Key], the drive door open, and the lighting switch in ON position, the warning chime will sound.
[Except when headlamp battery saver control operates (for 5 minutes after ignition switch is turned to OFF or
ACC position) and headlamps do not illuminate.]
Signal is supplied
from combination switch (lighting switch) terminals 1, 2, 3, 4, 5, 6, 7, 8, 9 and 10
to BCM terminals 2, 3, 4, 5, 6, 32, 33, 34, 35 and 36.
NOTE:
BCM detected lighting switch in 1st or 2nd position, refer to LT- 1 8 3 , "
Combination Switch Reading Func-
tion" .
Ground is supplied
to BCM terminal 62
through front door switch (driver side) terminal 2.
Front door switch (driver side) is case grounded.
BCM detects headlamps are illuminated, and sends light warning signal to unified meter and A/C amp. with
CAN communication line. Unified meter and A/C amp. sends light warning signal to combination meter with
communication line between unified meter and A/C amp. and combination meter.
When combination meter receives light warning signal, it sounds warning chime.
WARNING CHIME
DI-63
C
D
E
F
G
H
I
J
L
MA
B
DI
Terminals and Reference Value for BCMBKS001T3
TerminalWire
colorItemMeasuring condition
Reference value
Ignition
switchOperation or condition
2 BR Combination switch input 5 ONLights, turn signals, wipers OFF
(Wiper dial position 4)
3 R/Y Combination switch input 4 ONLights, turn signals, wipers OFF
(Wiper dial position 4)
4 R Combination switch input 3 ONLights, turn signals, wipers OFF
(Wiper dial position 4)
5 Y/B Combination switch input 2
ONLights, turn signals, wipers OFF
(Wiper dial position 4)
6 R/W Combination switch input 1
32 LG/B Combination switch output 5 ONLights, turn signals, wipers OFF
(Wiper dial position 4)
33 G/Y Combination switch output 4 ONLights, turn signals, wipers OFF
(Wiper dial position 4)
34 L/W Combination switch output 3 ONLights, turn signals, wipers OFF
(Wiper dial position 4)
SKIA5291E
SKIA5292E
SKIA5291E
SKIA5292E
SKIA5291E
SKIA5292E
SKIA5291E
DI-64
WARNING CHIME
*1: With Intelligent key
*2: Without Intelligent key
Terminals and Reference Value for Unified Meter and A/C Amp. BKS001T4
35 G/B Combination switch output 2
ONLights, turn signals, wipers OFF
(Wiper dial position 4)
36 G/W Combination switch output 1
37B/R
*1
BR*2Key switch signal OFFKey is removed Approx. 0V
Key is inserted Approx. 12V
38 R Ignition switch ON or START ON — Battery voltage
39 L CAN-H OFF — —
40 P CAN-L OFF — —
42 Y/R Battery power supply OFF — Battery voltage
52 B Ground ON — Approx. 0V
55 W/B Battery power supply OFF — Battery voltage
62 SB Front door switch (driver side) OFFWhen driver door is opened
(Door switch ON)Approx. 0V
When driver door is closed
(Door switch OFF)Approx. 12V Te r m i n a lWire
colorItemMeasuring condition
Reference value
Ignition
switchOperation or condition
SKIA5292E
Te r m i n a lWire
colorItem Measuring condition
Reference value
Ignition
switchOperation or condition
1 L CAN-H OFF — —
9RTX communication line (To
combination meter)ON —
11 P C A N - L O F F — —
19 G/BRX communication line
(From combination meter)ON —
21 Y/R Battery power supply OFF — Battery voltage
22 G Ignition switch ON or START ON — Battery voltage
29 B Ground (power) ON — Approx. 0V
30 B Ground ON — Approx. 0V
SKIA3362E
SKIA3361E
DI-66
WARNING CHIME
Display Item List
ACTIVE TEST
Operation procedure
1. Touch “BUZZER” on “SELECT TEST ITEM” screen.
2. Touch “ACTIVE TEST” on “SELECT DIAG MODE” screen.
3. Touch the item to be tested, and check the operation.
4. During the operation check, touching “OFF” deactivates the operation.
Display Item LIst
Trouble DiagnosisBKS001T7
HOW TO PROCEED WITH TROUBLE DIAGNOSIS
1. Confirm the malfunction symptom or customer complaint.
2. Understand the outline of system. Refer to DI-56, "
System Description" .
3. Perform preliminary check. Refer to DI-66, "
PRELIMINARY CHECK" .
4. Select “METER A/C AMP” on CONSULT-II, and then perform self-diagnosis of unified meter and A/C
amp. Refer to DI-29, "
CONSULT-II Function (METER A/C AMP)" . When no malfunction detected, go to
next step 5. When malfunction detected, go to DI-17, "
SYMPTOM CHART 2" in “COMBINATION
METER”.
5. Check symptom and repair or replace the cause of malfunction.
6. Does the warning chime operate normally? If so, GO TO 7. If not, GO TO 5.
7. INSPECTION END
PRELIMINARY CHECK
1. CHECK FUSE AND FUSIBLE LINK
Check BCM fuses and fusible link for blown-out.
OK or NG
OK >> GO TO 2.
NG >> If fuse or fusible link is blown, be sure to eliminate cause of malfunction before installing new fuse
or fusible link. Refer to PG-3, "
POWER SUPPLY ROUTING CIRCUIT" .
Monitor item [Unit] ALL SIGNALSSELECTION
FROM MENUDescription
IGN ON SW [ON/OFF] X X Indicates [ON/OFF] condition of ignition switch.
KEY ON SW [ON/OFF] X X Indicates [ON/OFF] condition of key switch.
DOOR SW-DR [ON/OFF] X X Indicates [ON/OFF] condition of front door switch (driver side).
LIGHT SW 1ST [ON/OFF] X X Indicates [ON/OFF] condition of lighting switch.
FR FOG SW [ON/OFF] X X Indicates [ON/OFF] condition of front fog lamp switch.
Test item Malfunction is detected when···
IGN KEY WARN ALMThis test is able to check key warning chime operation. Key warning chime sounds for 2 seconds
after touching “ON” on CONSULT-ll screen.
LIGHT WARN ALMThis test is able to check light warning chime operation. Light warning chime sounds for 2 seconds
after touching “ON” on CONSULT-ll screen.
Unit Power source Fuse and fusible link No.
BCMBatteryM
17
Ignition switch ON or START 1
WARNING CHIME
DI-67
C
D
E
F
G
H
I
J
L
MA
B
DI
2. CHECK POWER SUPPLY CIRCUIT
Check voltage between BCM harness connector terminals and
ground.
OK or NG
OK >> GO TO 3.
NG >> Check harness between BCM and fuse or fusible link.
3. CHECK GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM connector.
3. Check continuity between BCM harness connector M4 terminal
52 and ground.
OK or NG
OK >> INSPECTION END
NG >> Repair harness or connector.
Key Warning Chime and Light Warning Chime Does Not OperatedBKS001T8
1. CHECK CHIME OPERATION
1. Select “BCM” on CONSULT-II.
2. Select “BUZZER” on CONSULT-ll, and then perform “LIGHT
WARN ALM” or “IGN KEY WARN ALM” of “ACTIVE TEST”.
Does chime sound?
YES >> GO TO 3.
NO >> GO TO 2.
Terminals Ignition switch position
(+)
(–) OFF ON
Connector Terminal
M455
GroundBattery voltage Battery voltage
42 Battery voltage Battery voltage
M3 38 0 V Battery voltage
SKIB0785E
52 – Ground : Continuity should exist.
SKIB0226E
SKIA6331E
WARNING CHIME
DI-69
C
D
E
F
G
H
I
J
L
MA
B
DI
4. CHECK FRONT DOOR SWITCH (DRIVER SIDE) CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM connector and front door switch (driver side) connector.
3. Check continuity between BCM harness connector M5 terminal
62 and front door switch (driver side) harness connector B10 ter-
minal 2.
4. Check continuity between BCM harness connector M5 terminal
62 and ground.
OK or NG
OK >> GO TO 5.
NG >> Repair harness or connector.
5. CHECK FRONT DOOR SWITCH (DRIVER SIDE)
Check front door switch (driver side).
OK or NG
OK >> Replace BCM. Refer to BCS-16, "Removal and Installa-
tion of BCM" .
NG >> Replace front door switch (driver side).
Key Warning Chime Does Not Operate (Without Intelligent Key)BKS001T9
1. CHECK FUSE
Check if the key switch 15A fuse [No. 17, located in the fuse block (J/B)] is blown. Refer to DI-60, "
Wiring Dia-
gram — CHIME —" .
Is the fuse blown?
YES >> Replace fuse. Be sure to repair the cause of malfunction before installing new fuse.
NO >> GO TO 2.
2. CHECK WARNING CHIME OPERATION
Check the chime under conditions in exception of key warning chime (without Intelligent Key) operation.
Does warning chime sound?
YES >> GO TO 3.
NO >> Go to DI-67, "
Key Warning Chime and Light Warning Chime Does Not Operated" . 62 – 2 : Continuity should exist.
62 – Ground : Continuity should not exist.
SKIB0225E
2 - Case ground
When driver door
switch is released: Continuity should exist.
When driver door
switch is pushed: Continuity should not exist.
SKIB0324E
WARNING CHIME
DI-71
C
D
E
F
G
H
I
J
L
MA
B
DI
5. CHECK KEY SWITCH CIRCUIT
1. Disconnect BCM connector.
2. Check continuity between BCM harness connector M3 terminal
37 and key switch harness connector M34 terminal 4.
3. Check continuity between BCM harness connector M3 terminal
37 and ground.
OK or NG
OK >> GO TO 6.
NG >> Repair harness or connector.
6. CHECK KEY SWITCH POWER SUPPLY CIRCUIT
Check voltage between key switch harness connector M34 terminal
1 and ground.
OK or NG
OK >> Replace BCM. Refer to BCS-16, "Removal and Installa-
tion of BCM" .
NG >> Check harness between key switch and fuse.
Key Warning Chime Does Not Operate (With Intelligent Key, When Mechanical
Key Is Used)
BKS001TA
1. CHECK FUSE
Check if the key switch 15A fuse [No. 18, located in the fuse block (J/B)] is blown. Refer to DI-60, "
Wiring Dia-
gram — CHIME —" .
Is the fuse blown?
YES >> Replace fuse. Be sure to repair the cause of malfunction before installing new fuse.
NO >> GO TO 2.
2. CHECK WARNING CHIME OPERATION
Check the chime under conditions in exception of key warning chime (when mechanical key is used) opera-
tion.
Does warning chime sound?
YES >> GO TO 3.
NO >> Go to DI-67, "
Key Warning Chime and Light Warning Chime Does Not Operated" . 37 – 4 : Continuity should exist.
37 – Ground : Continuity should not exist.
SKIA8696E
1 – Ground : Battery voltage.
SKIA8697E