Page 1569 of 3502
![NISSAN TEANA 2003 Service Manual EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-287
[QR]
C
D
E
F
G
H
I
J
K
L
MA
EC
6. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIR-
CUIT FOR OPEN AND SHORT
1. Turn NISSAN TEANA 2003 Service Manual EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-287
[QR]
C
D
E
F
G
H
I
J
K
L
MA
EC
6. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIR-
CUIT FOR OPEN AND SHORT
1. Turn](/manual-img/5/57392/w960_57392-1568.png)
EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-287
[QR]
C
D
E
F
G
H
I
J
K
L
MA
EC
6. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIR-
CUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between EVAP canister purge volume control solenoid valve terminal 2 and
ECM terminal 19. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK (With CONSULT-II)>>GO TO 7.
OK (Without CONSULT-II)>>GO TO 8.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
7. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
With CONSULT-II
1. Reconnect all harness connectors disconnected.
2. Start engine.
3. Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode with
CONSULT-II. Check that engine speed varies according to the
valve opening.
OK or NG
OK >> GO TO 9.
NG >> GO TO 8.
8. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Refer to EC-288, "
Component Inspection" .
OK or NG
OK >> GO TO 9.
NG >> Replace EVAP canister purge volume control solenoid valve.
9. CHECK INTERMITTENT INCIDENT
Refer to EC-105, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END Continuity should exist.
PBIB0569E
Page 1574 of 3502
EC-292
[QR]
FUEL INJECTOR
2. CHECK OVERALL FUNCTION
With CONSULT-II
1. Start engine.
2. Perform “POWER BALANCE” in “ACTIVE TEST” mode with
CONSULT-II.
3. Make sure that each circuit produces a momentary engine
speed drop.
Without CONSULT-II
1. Start engine.
2. Listen to each fuel injector operating sound.
OK or NG
OK >>INSPECTION END
NG >> GO TO 3.
3. CHECK FUEL INJECTOR POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect fuel injector harness connector.
3. Turn ignition switch ON.
4. Check voltage between fuel injector terminal 1 and ground with
CONSULT-II or tester.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
PBIB0133E
Clicking noise should be heard.
PBIB1986E
PBIB3290E
Voltage: Battery voltage
PBIB0582E
Page 1575 of 3502
![NISSAN TEANA 2003 Service Manual FUEL INJECTOR
EC-293
[QR]
C
D
E
F
G
H
I
J
K
L
MA
EC
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors M52, F103
Harness connectors F1, F251
Fuse block (J/B) connector M1
10A NISSAN TEANA 2003 Service Manual FUEL INJECTOR
EC-293
[QR]
C
D
E
F
G
H
I
J
K
L
MA
EC
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors M52, F103
Harness connectors F1, F251
Fuse block (J/B) connector M1
10A](/manual-img/5/57392/w960_57392-1574.png)
FUEL INJECTOR
EC-293
[QR]
C
D
E
F
G
H
I
J
K
L
MA
EC
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors M52, F103
Harness connectors F1, F251
Fuse block (J/B) connector M1
10A fuse
Harness for open or short between fuel injector and fuse
>> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK FUEL INJECTOR OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between fuel injector terminal 2 and ECM terminals 22, 23, 41, 42.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 7.
NG >> GO TO 6.
6. DETECT MALFONCTIONING PART
Check the following.
Harness connectors F1, F251
Harness for open or short between fuel injector and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
7. CHECK FUEL INJECTOR
Refer to EC-293, "
Component Inspection" .
OK or NG
OK >> GO TO 8.
NG >> Replace malfunctioning fuel injector.
8. CHECK INTERMITTENT INCIDENT
Refer to EC-105, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionBBS005IK
FUEL INJECTOR
1. Disconnect fuel injector harness connector.Continuity should exist.
Page 1579 of 3502
![NISSAN TEANA 2003 Service Manual FUEL PUMP
EC-297
[QR]
C
D
E
F
G
H
I
J
K
L
MA
EC
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring inp NISSAN TEANA 2003 Service Manual FUEL PUMP
EC-297
[QR]
C
D
E
F
G
H
I
J
K
L
MA
EC
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring inp](/manual-img/5/57392/w960_57392-1578.png)
FUEL PUMP
EC-297
[QR]
C
D
E
F
G
H
I
J
K
L
MA
EC
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureBBS005IP
1. CHECK OVERALL FUNCTION
1. Turn ignition switch ON.
2. Pinch fuel feed hose with two fingers.
OK or NG
OK >>INSPECTION END
NG >> GO TO 2.
2. CHECK FUEL PUMP POWER SUPPLY CIRCUIT-I
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Turn ignition switch ON.
4. Check voltage between ECM terminal 113 and ground with
CONSULT-II or tester.
OK or NG
OK >> GO TO 5.
NG >> GO TO 3.
TERMI-
NAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
113 B/R Fuel pump relay[Ignition switch: ON]
For 1 second after turning ignition switch
ON
[Engine is running]0 - 1.0V
[Ignition switch: ON]
More than 1 second after turning ignition
switch ONBATTERY VOLTAGE
(11 - 14V)
Fuel pressure pulsation should be felt on the fuel
hose for 1 second after ignition switch is turned ON.
PBIB2140E
Voltage: Battery voltage
PBIB1187E
Page 1580 of 3502
![NISSAN TEANA 2003 Service Manual EC-298
[QR]
FUEL PUMP
3. CHECK FUEL PUMP POWER SUPPLY CIRCUIT-II
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R harness connector E8.
3. Check harness continuity between ECM terminal 113 and IP NISSAN TEANA 2003 Service Manual EC-298
[QR]
FUEL PUMP
3. CHECK FUEL PUMP POWER SUPPLY CIRCUIT-II
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R harness connector E8.
3. Check harness continuity between ECM terminal 113 and IP](/manual-img/5/57392/w960_57392-1579.png)
EC-298
[QR]
FUEL PUMP
3. CHECK FUEL PUMP POWER SUPPLY CIRCUIT-II
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R harness connector E8.
3. Check harness continuity between ECM terminal 113 and IPDM E/R terminal 40.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 13.
NG >> GO TO 4.
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E206, M13
Harness for open or short between IPDM E/R and ECM
>> Repair harness or connectors.
5. CHECK CONDENSER POWER SUPPLY CIRCUIT-I
1. Turn ignition switch OFF.
2. Reconnect all harness connectors disconnected.
3. Disconnect condenser harness connector.
4. Turn ignition switch ON.
5. Check voltage between condenser terminal 1 and ground with
CONSULT-II or tester.
OK or NG
OK >> GO TO 9.
NG >> GO TO 6.
6. CHECK 15A FUSE
1. Turn ignition switch OFF.
2. Disconnect 15A fuse.
3. Check 15A fuse.
OK or NG
OK >> GO TO 7.
NG >> Replace fuse.Continuity should exist.
Voltage: Battery voltage should exist for 1 second
after ignition switch is turned ON.
PBIB0624E
Page 1581 of 3502
![NISSAN TEANA 2003 Service Manual FUEL PUMP
EC-299
[QR]
C
D
E
F
G
H
I
J
K
L
MA
EC
7. CHECK CONDENSER POWER SUPPLY CIRCUIT-II
1. Disconnect IPDM E/R harness connector E8.
2. Check harness continuity between IPDM E/R terminal 39 and c NISSAN TEANA 2003 Service Manual FUEL PUMP
EC-299
[QR]
C
D
E
F
G
H
I
J
K
L
MA
EC
7. CHECK CONDENSER POWER SUPPLY CIRCUIT-II
1. Disconnect IPDM E/R harness connector E8.
2. Check harness continuity between IPDM E/R terminal 39 and c](/manual-img/5/57392/w960_57392-1580.png)
FUEL PUMP
EC-299
[QR]
C
D
E
F
G
H
I
J
K
L
MA
EC
7. CHECK CONDENSER POWER SUPPLY CIRCUIT-II
1. Disconnect IPDM E/R harness connector E8.
2. Check harness continuity between IPDM E/R terminal 39 and condenser terminal 1.
Refer to Wiring Diagram.
3. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 13.
NG >> GO TO 8.
8. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E11, E253
Harness connectors E104, B202
Harness for open or short between IPDM E/R and condenser
>> Repair open circuit or short to ground or short to power in harness or connectors.
9. CHECK CONDENSER GROUND CIRCUIT
1. Check harness continuity between condenser terminal 2 and ground.
Refer to Wiring Diagram.
2. Also check harness for short to power.
OK or NG
OK >> GO TO 10.
NG >> Repair open circuit or short to power in harness or connectors.
10. CHECK CONDENSER
Refer to EC-300, "
Component Inspection" .
OK or NG
OK >> GO TO 11.
NG >> Replace condenser.
11 . CHECK FUEL PUMP POWER SUPPLY AND GROUND CIRCUIT FOR OPEN AND SHORT
1. Disconnect harness connectors E104, B202.
2. Disconnect “fuel level sensor unit and fuel pump” harness con-
nector.
3. Check harness continuity between “fuel level sensor unit and
fuel pump” terminal 1 and harness connector B202 terminal 1,
“fuel level sensor unit and fuel pump” terminal 3 and ground.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 12.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.Continuity should exist.
Continuity should exist.
Continuity should exist.PBIB2121E
Page 1587 of 3502
![NISSAN TEANA 2003 Service Manual HO2S1
EC-305
[QR]
C
D
E
F
G
H
I
J
K
L
MA
EC
3. CHECK HO2S1 GROUND CIRCUIT FOR OPEN AND SHORT
1. Disconnect heated oxygen sensor 1 harness connector.
2. Disconnect ECM harness connector.
3. Check har NISSAN TEANA 2003 Service Manual HO2S1
EC-305
[QR]
C
D
E
F
G
H
I
J
K
L
MA
EC
3. CHECK HO2S1 GROUND CIRCUIT FOR OPEN AND SHORT
1. Disconnect heated oxygen sensor 1 harness connector.
2. Disconnect ECM harness connector.
3. Check har](/manual-img/5/57392/w960_57392-1586.png)
HO2S1
EC-305
[QR]
C
D
E
F
G
H
I
J
K
L
MA
EC
3. CHECK HO2S1 GROUND CIRCUIT FOR OPEN AND SHORT
1. Disconnect heated oxygen sensor 1 harness connector.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 74 and HO2S1
terminal 4.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 4.
NG >> Repair open circuit or short to ground or short to power
in harness or connectors.
4. CHECK HO2S1 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between ECM terminal 35 and HO2S1 terminal 1.
Refer to Wiring Diagram.
2. Check harness continuity between ECM terminal 35 or HO2S1 terminal 1 and ground.
Refer to Wiring Diagram.
3. Also check harness for short to power.
OK or NG
OK >> GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK HEATED OXYGEN SENSOR 1
Refer to EC-305, "
Component Inspection" .
OK or NG
OK >> GO TO 6.
NG >> Replace heated oxygen sensor 1.
6. CHECK INTERMITTENT INCIDENT
Refer to EC-105, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionBBS005IW
HEATED OXYGEN SENSOR 1
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select “MANU TRIG” and adjust “TRIGGER POINT” to 100% in “DATA MONITOR” mode with CONSULT-
II. Continuity should exist.
PBIB2136E
Continuity should exist.
Continuity should not exist.
Page 1593 of 3502
HO2S1 HEATER
EC-311
[QR]
C
D
E
F
G
H
I
J
K
L
MA
EC
2. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten two ground screws on the body.
Refer to E C - 111 , "
Ground Inspection" .
OK or NG
OK >> GO TO 3.
NG >> Repair or replace ground connections.
3. CHECK HO2S1 POWER SUPPLY CIRCUIT
1. Disconnect heated oxygen sensor 1 harness connector.
2. Turn ignition switch ON.
3. Check voltage between HO2S1 terminal 3 and ground with
CONSULT-II or tester.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E39, F41
Fuse block (J/B) connector E7
15A fuse
Harness for open or short between heated oxygen sensor 1 and fuse
>> Repair open circuit or short to ground or short to power in harness or connectors.
PBIB2160E
PBIB2136E
Voltage: Battery voltage
PBIB0112E