EC-276
[QG (WITH EURO-OBD)]
DTC P1121 ELECTRIC THROTTLE CONTROL ACTUATOR
DTC P1121 ELECTRIC THROTTLE CONTROL ACTUATOR
PFP:16119
Component DescriptionEBS00K9O
Electric Throttle Control Actuator consists of throttle control motor, throttle position sensor, etc.
The throttle control motor is operated by the ECM and it opens and closes the throttle valve.
The throttle position sensor detects the throttle valve position, and the opening and closing speed of the throt-
tle valve and feeds the voltage signals to the ECM. The ECM judges the current opening angle of the throttle
valve from these signals and the ECM controls the throttle control motor to make the throttle valve opening
angle properly in response to driving condition.
On Board Diagnosis LogicEBS00K9P
FAIL-SAFE MODE
When the malfunction A or B is detected in the two consecutive trips, the ECM enters fail-safe mode and MI
lights up.
When the malfunction C is detected even in the 1st trip, the ECM enters fail-safe mode and the MI lights up
DTC Confirmation ProcedureEBS00K9Q
NOTE:
●Perform “PROCEDURE FOR MALFUNCTION A AND B” first. If the 1st trip DTC cannot be con-
firmed, perform “PROCEDURE FOR MALFUNCTION C”.
●If there is no malfunction on “PROCEDURE FOR MALFUNCTION A AND B”, perform “PROCEDURE
FOR MALFUNCTION C”.
●If “DTC Confirmation Procedure” has been previously conducted, always turn ignition switch “OFF” and
wait at least 10 seconds before conducting the next test.
PROCEDURE FOR MALFUNCTION A AND B
With CONSULT-II
1. Turn ignition witch “ON” and wait at least 1 second.
2. Select “DATA MONITOR” mode with CONSULT-II.
3. Shift selector lever to “D” position (A/T), “1st” position (M/T) and
wait at least 2 seconds.
4. Turn ignition switch “OFF”, wait at least 10 seconds, and then
turn “ON”.
5. If 1st trip DTC is detected, go to EC-277, "
Diagnostic Procedure"
.
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P1121
1121Electric throttle control
actuatorA)Electric throttle control actuator does not function
properly due to the return spring malfunction.
●Electric throttle control actuator B)Throttle valve opening angle in fail-safe mode is
not in specified range.
C)ECM detect the throttle valve is stuck open.
This self-diagnosis has the one trip detection
logic.
Detected items Engine operating condition in fail-safe mode
Malfunction AThe ECM controls the electric throttle actuator by regulating the throttle opening around the idle position.
The engine speed will not rise more than 2,000 rpm.
Malfunction B ECM controls the electric throttle control actuator by regulating the throttle opening to 20 degrees or less.
Malfunction CWhile the vehicle is driving, it slows down gradually by fuel cut. After the vehicle stops, the engine stalls.
The engine can restart in “N” or “P” position, and engine speed will not exceed 1,000 rpm or more.
SEF058Y
EC-296
[QG (WITH EURO-OBD)]
DTC P1143 HO2S1
DTC P1143 HO2S1
PFP:22690
Component DescriptionEBS00KAE
The heated oxygen sensor 1 is placed into the exhaust manifold. It
detects the amount of oxygen in the exhaust gas compared to the
outside air. The heated oxygen sensor 1 has a closed-end tube
made of ceramic zirconia. The zirconia generates voltage from
approximately 1V in richer conditions to 0V in leaner conditions. The
heated oxygen sensor 1 signal is sent to the ECM. The ECM adjusts
the injection pulse duration to achieve the ideal air-fuel ratio. The
ideal air-fuel ratio occurs near the radical change from 1V to 0V.
CONSULT-II Reference Value in Data Monitor ModeEBS00KAF
Specification data are reference values.
On Board Diagnosis LogicEBS00KAG
To judge the malfunction, the output from the heated oxygen sensor
1 is monitored to determine whether the “rich” output is sufficiently
high and whether the “lean” output is sufficiently low. When both the
outputs are shifting to the lean side, the malfunction will be detected.
SEF463R
SEF288D
MONITOR ITEM CONDITION SPECIFICATION
HO2S1 (B1)
●Engine: After warming upMaintaining engine speed at 2,000
rpm0 - 0.3V ←→ Approx. 0.6 - 1.0V
HO2S1 MNTR (B1)
●Engine: After warming upMaintaining engine speed at 2,000
rpmLEAN ←→ RICH
Changes more than 5 times dur-
ing 10 seconds.
SEF300U
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P1143
1143Heated oxygen sensor 1
lean shift monitoringThe maximum and minimum voltage from the
sensor are not reached to the specified voltages.
●Heated oxygen sensor 1
●Heated oxygen sensor 1 heater
●Fuel pressure
●Injectors
●Intake air leaks
DTC P1143 HO2S1
EC-297
[QG (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
DTC Confirmation ProcedureEBS00KAH
CAUTION:
Always drive vehicle at a safe speed.
NOTE:
If “DTC Confirmation Procedure” has been previously conducted, always turn ignition switch “OFF” and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
●Always perform at a temperature above −10°C (14°F).
●Before performing following procedure, confirm that battery voltage is more than 11V at idle.
WITH CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Stop engine and wait at least 10 seconds.
3. Turn ignition switch “ON” and select “HO2S1 (B1) P1143” of “HO2S1” in “DTC WORK SUPPORT” mode
with CONSULT-II.
4. Touch “START”.
5. Start engine and let it idle for at least 3 minutes.
NOTE:
Never raise engine speed above 3,600 rpm (M/T models) or
3,200 rpm (A/T models) after this step. If the engine speed
limit is exceeded, return to step 5.
6. When the following conditions are met, “TESTING” will be dis-
played on the CONSULT-II screen. Maintain the conditions con-
tinuously until “TESTING” changes to “COMPLETED”. (It will
take approximately 50 seconds or more.)
If “TESTING” is not displayed after 5 minutes, retry from
step 2.
7. Make sure that “OK” is displayed after touching “SELF-DIAG
RESULTS”. If “NG” is displayed, refer to EC-298, "
Diagnostic
Procedure" .
PBIB0546E
ENG SPEED 1,200 - 2,600 rpm (A/T models)
1,700 - 2,600 rpm (M/T models)
Vehicle speed 50 - 100 km/h (30 - 62 MPH)
B/FUEL SCHDL 3.0 - 5.2 msec
Selector lever Suitable position
PBIB0547E
SEC769C
EC-302
[QG (WITH EURO-OBD)]
DTC P1144 HO2S1
DTC P1144 HO2S1
PFP:22690
Component DescriptionEBS00KAM
The heated oxygen sensor 1 is placed into the exhaust manifold. It
detects the amount of oxygen in the exhaust gas compared to the
outside air. The heated oxygen sensor 1 has a closed-end tube
made of ceramic zirconia. The zirconia generates voltage from
approximately 1V in richer conditions to 0V in leaner conditions. The
heated oxygen sensor 1 signal is sent to the ECM. The ECM adjusts
the injection pulse duration to achieve the ideal air-fuel ratio. The
ideal air-fuel ratio occurs near the radical change from 1V to 0V.
CONSULT-II Reference Value in Data Monitor ModeEBS00KAN
Specification data are reference values.
On Board Diagnosis LogicEBS00KAO
To judge the malfunction, the output from the heated oxygen sensor
1 is monitored to determine whether the “rich” output is sufficiently
high. The “lean” output is sufficiently low. When both the outputs are
shifting to the rich side, the malfunction will be detected.
SEF463R
SEF288D
MONITOR ITEM CONDITION SPECIFICATION
HO2S1 (B1)
●Engine: After warming upMaintaining engine speed at 2,000
rpm0 - 0.3V ←→ Approx. 0.6 - 1.0V
HO2S1 MNTR (B1)
●Engine: After warming upMaintaining engine speed at 2,000
rpmLEAN ←→ RICH
Changes more than 5 times dur-
ing 10 seconds.
SEF299U
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P1144
1144Heated oxygen sensor 1
rich shift monitoringThe maximum and minimum voltages from the
sensor are beyond the specified voltages.
●Heated oxygen sensor 1
●Heated oxygen sensor 1 heater
●Fuel pressure
●Injectors
DTC P1144 HO2S1
EC-303
[QG (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
DTC Confirmation ProcedureEBS00KAP
CAUTION:
Always drive vehicle at a safe speed.
NOTE:
If “DTC Confirmation Procedure” has been previously conducted, always turn ignition switch “OFF” and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
●Always perform at a temperature above −10°C (14°F).
●Before performing the following procedure, confirm that battery voltage is more than 11V at idle.
WITH CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Stop engine and wait at least 5 seconds.
3. Turn ignition switch “ON” and select “HO2S1 (B1) P1144” of “HO2S1” in “DTC WORK SUPPORT” mode
with CONSULT-II.
4. Touch “START”.
5. Start engine and let it idle for at least 3 minutes.
NOTE:
Never raise engine speed above 3,600 rpm (M/T models) or
3,200 rpm (A/T models) after this step. If the engine speed
limit is exceeded, return to step 5.
6. When the following conditions are met, “TESTING” will be dis-
played on the CONSULT-II screen. Maintain the conditions con-
tinuously until “TESTING” changes to “COMPLETED”. (It will
take approximately 50 seconds or more.)
If “TESTING” is not displayed after 5 minutes, retry from
step 2.
7. Make sure that “OK” is displayed after touching “SELF-DIAG
RESULTS”. If “NG” is displayed, refer to EC-304, "
Diagnostic
Procedure" .
PBIB0548E
ENG SPEED 1,200 - 2,600 rpm (A/T models)
1,700 - 2,600 rpm (M/T models)
Vehicle speed 50 - 100 km/h (30 - 62 MPH)
B/FUEL SCHDL 3.0 - 5.2 msec
Selector lever Suitable position
PBIB0549E
SEC772C
EC-308
[QG (WITH EURO-OBD)]
DTC P1146 HO2S2
DTC P1146 HO2S2
PFP:226A0
Component DescriptionEBS00KAU
The heated oxygen sensor 2, after three way catalyst (manifold),
monitors the oxygen level in the exhaust gas.
Even if switching characteristics of the heated oxygen sensor 1 are
shifted, the air-fuel ratio is controlled to stoichiometric, by the signal
from the heated oxygen sensor 2.
This sensor is made of ceramic zirconia. The zirconia generates volt-
age from approximately 1V in richer conditions to 0V in leaner condi-
tions.
Under normal conditions the heated oxygen sensor 2 is not used for
engine control operation.
CONSULT-II Reference Value in Data Monitor ModeEBS00KAV
Specification data are reference values.
On Board Diagnosis LogicEBS00KAW
The heated oxygen sensor 2 has a much longer switching time
between rich and lean than the heated oxygen sensor 1. The oxygen
storage capacity before the three way catalyst (manifold) causes the
longer switching time. To judge the malfunctions of heated oxygen
sensor 2, ECM monitors whether the minimum voltage of sensor is
sufficiently low during the various driving condition such as fuel-cut.
DTC Confirmation ProcedureEBS00KAX
CAUTION:
Always drive vehicle at a safe speed.
NOTE:
●“COMPLETED” will appear on CONSULT-II screen when all tests “COND1”, “COND2” and
“COND3” are completed.
SEF327R
MONITOR ITEM CONDITION SPECIFICATION
HO2S2 (B1)
●Engine: After warming up
●Keeping the engine speed
between 3,500 and 4,000 rpm
for one minute and at idle for
one minute under no loadRevving engine from idle to 3,000
rpm quickly.0 - 0.3V ←→ Approx. 0.6 - 1.0V
HO2S2 MNTR (B1)
●Engine: After warming up
●Keeping the engine speed
between 3,500 and 4,000 rpm
for one minute and at idle for
one minute under no loadRevving engine from idle to 3,000
rpm quickly.LEAN ←→ RICH
SEF258VA
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P1146
1146Heated oxygen sensor 2
minimum voltage monitoringThe minimum voltage from the sensor is not
reached to the specified voltage.
●Harness or connectors
(The sensor circuit is open or shorted.)
●Heated oxygen sensor 2
●Fuel pressure
●Injectors
DTC P1146 HO2S2
EC-309
[QG (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
●If “DTC confirmation Procedure” has been previously conducted, always turn ignition switch “OFF” and
wait at least 10 seconds before conducting the next test.
TESTING CONDITION:
Never stop engine during this procedure. If the engine is stopped, retry procedure from step 2 in “Pro-
cedure for COND1”
WITH CONSULT-II
Procedure for COND1
For the best results, perform ″DTC WORK SUPPORT″ at a temperature of 0 to 30°C (32 to 86°F).
1. Start engine and warm it up to the normal operating temperature.
2. Turn ignition switch ″OFF″ and wait at least 10 seconds.
3. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least one minute under no
load.
4. Let engine idle for one minute.
5. Select “HO2S2 (B1) P1146” of “HO2S2” in “DTC WORK SUPPORT” mode with CONSULT-II.
6. Touch START”.
7. Let it idle for at least 30 seconds.
8. Rev engine up to 2,000 rpm 2 or 3 times quickly under no load.
If “COMPLETED” appears on CONSULT-II screen, go to step 2 in Procedure for COND3”.
If “COMPLETED” does not appear on CONSULT-II screen, go to the following step.
9. When the following conditions are met, “TESTING” will be displayed at “COND1” on the CONSULT-II
screen. Maintain the conditions continuously until “TESTING” changes to “COMPLETED”. (It will take
approximately 60 seconds.)
NOTE:
●If “TESTING” is not displayed after 5 minutes, retry from step 2 in “Procedure for COND1”.
●If “COMPLETED” already appears at “COND2” on CONSULT-II screen before “Procedure for
COND2” is conducted, it is unnecessary to conduct step 1 in “Procedure for COND2”.
Procedure for COND2
1. While driving, release accelerator pedal completed with “OD”
OFF (A/T models only) from the above condition [step 9] until
“INCOMPLETE” at “COND2” on CONSULT-II screen has turned
to “COMPLETED” (It will take approximately 4 seconds.)
NOTE:
If “COMPLETE” already appears at “COND3” on CONSULT-
II screen before “Procedure for COND3” is conducted, it is
unnecessary to conduct step 1 in “Procedure for COND3”.
ENG SPEED More than 1,000 rpm
B/FUEL SCHDL More than 1.0 msec
COOLANT TEMP/S 70 - 105°C
Selector lever Suitable position
PBIB0555E
PBIB0556E
EC-314
[QG (WITH EURO-OBD)]
DTC P1146 HO2S2
4. CHECK HO2S2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between ECM terminal 16 and HO2S2 terminal 2.
Refer to Wiring Diagram.
2. Check harness continuity between ECM terminal 16 or HO2S2 terminal 2 and ground.
Refer to Wiring Diagram.
3. Also check harness for short to power.
OK or NG
OK >> GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK HEATED OXYGEN SENSOR 2
Refer to EC-314, "
Component Inspection" .
OK or NG
OK >> GO TO 6.
NG >> Replace heated oxygen sensor 2.
6. CHECK INTERMITTENT INCIDENT
Refer to EC-109, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionEBS00KB1
HEATED OXYGEN SENSOR 2
With CONSULT-II
1. Start engine and warm it up to the normal operating temperature.
2. Turn ignition switch ″OFF″ and wait at least 10 seconds.
3. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least one minute under no
load.
4. Let engine idle and wait until 2 minutes have passed from starting the engine.
5. Select “FUEL INJECTION” in “ACTIVE TEST” mode, and select
“HO2S2 (B1)” as the monitor item with CONSULT-II.Continuity should exist.
Continuity should not exist.
SEF662Y