ENGINE CONTROLS 1F–179
DAEWOO M-150 BL2
DTC P1385 – Rough Road Sensor Circuit Fault (ABS)
StepActionValue(s)YesNo
1
Perform an Euro On-Board Diagnostic (EOBD)
System Check.
Was the check performed?
–
Go to Step 2
Go to
“On-Board
Diagnostic
System Check”
2
1. Turn the ignition ON, with engine OFF.
2. Install a scan tool to the Data Link Connector
(DLC).
3. Review and record the scan tool Failure Records
data.
4. Operate the vehicle within Failure Records
conditions as noted.
5. Using the scan tool, monitor specific Diagnostic
Trouble Code (DTC) info for DTC P1385.
Does the scan tool indicate that DTC P1385 failed?
–
Go to Step 4Go to Step 3
3
1. Check for the following conditions and repair as
needed:
2. Wheel speed sensor seal missing or damaged.
3. Wheel speed sensor mounting flanges cracked,
missing, or incorrectly installed.
Is the repair complete?
–
Go to Step 14
Go to
“Diagnostic
Aids”
4
1. Turn the ignition OFF.
2. Disconnect the defected Wheel speed sensor
electrical connector.
3. Turn the ignition ON, with the engine OFF.
4. Observe the Wheel speed sensor value displayed
on the scan tool.
Is the Wheel speed sensor value near the specified
value?
0VGo to Step 5Go to Step 12
5
1. Jumper the 5 volt reference circuit, the Wheel
speed sensor signal circuit, together at the
defected Wheel speed sensor harness connector.
2. Observe the defected Wheel speed sensor value
displayed on the scan tool.
Is the VR sensor value near the specified value?
4.95VGo to Step 6Go to Step 7
6
1. Turn the ignition OFF.
2. Disconnect the Engine Control Module (ECM) and
check the sensor ground circuit for high
resistance, an open between the ECM and the
Wheel speed sensor, or for a poor connection of
the ECM and repair as needed.
Is the repair complete?
–
Go to Step 14Go to Step 10
7
Check the 5 volt reference circuit for high resistance,
an open between the ECM and the Wheel speed
sensor, or a poor connection of the ECM and repair
as needed.
Is the repair complete?
–
Go to Step 14Go to Step 8
8
1. Turn the ignition OFF.
2. Disconnect the ECM and check the Wheel speed
sensor signal circuit for high resistance, an open,
a low voltage, or a short to the sensor ground
circuit and repair as needed.
Is the repair complete?
–
Go to Step 14Go to Step 9
1F–180 ENGINE CONTROLS
DAEWOO M-150 BL2
DTC P1385 – Rough Road Sensor Circuit Fault (ABS) (Cont’d)
StepActionValue(s)YesNo
9
Check the Wheel speed sensor signal circuit for a
poor connection at the ECM and repair as needed.
Is the repair complete?
–
Go to Step 14Go to Step 13
10
Check for a poor connection at terminal 3 of the
Wheel speed sensor and repair as needed.
Is the repair complete?
–
Go to Step 14Go to Step 11
11Replace the Wheel speed sensor.
Is the repair complete?–Go to Step 14–
12
1. Turn the ignition OFF.
2. Disconnect the ECM.
3. Turn the ignition ON.
4. Check the Wheel speed sensor signal circuit for a
short to voltage or a short to the 5 volt reference
circuit and repair as needed.
Is the repair complete?
–
Go to Step 14Go to Step 13
13
1. Turn the ignition OFF.
2. Replace the ECM.
Is the repair complete?
–
Go to Step 14
–
14
1. Using the scan tool, clear the DTCs.
2. Start the engine and idle at normal operating
temperature.
3. Operate the vehicle within the conditions for
setting this DTC as specified in the supporting
text.
Does the scan tool indicate that this diagnostic ran
and passed?
–
Go to Step 15Go to Step 2
15
Check if any additional DTCs are set.
Are any DTCs displayed that have not been
diagnosed?
–
Go to
Applicable DTC
table
System OK
1F–182 ENGINE CONTROLS
DAEWOO M-150 BL2
MAA1F230
DIAGNOSTIC TROUBLE CODE (DTC) – P0400 ELECTRIC EXHAUST GAS
RECIRCULATION OUT OF LIMIT
Circuit Description
An Electric Exhaust Gas Re-circulation (EEGR) system
is used to lower oxides of nitrogen (NOX) emission lev-
els caused by high combustion temperatures. It a ac-
complishes this by feeding small amounts of exhaust
gases back into the combustion chamber. When the air/
fuel mixture is diluted with the exhaust gases, combus-
tion temperatures are reduced.
A EEGR valve is used on this system. The linear EEGR
valve is designed to accurately supply exhaust gases to
the engine without the use of intake manifold vacuum.
The valve controls exhaust flow going into the intake
manifold from the exhaust manifold fhrough an orifice
with a engine control module(ECM) controlled pintle.
The ECM controls the pintle position using inputs from
the Throttle Position (TP) and the Manifold Absolute
Pressure (MAP) sensor. The ECM then commands the
EEGR valve to operate when necessary by controlling
an ignition signal through the ECM. This can be moni-
tored on a scan tool as the Desired EEGR position.
The ECM monitors the results of its command through a
feedback signal. By sending a 5 volt reference and a
ground to the EEGR valve, a voltage signal representing
the EEGR valve pintle position is sent to the ECM. This
feedback signal can also be monitored on a scan tool
and is the actual position of the EEGR pintle. The actual
EEGR position should always be near the commanded
or Desired EEGR position.
ThisDiagnostic Trouble Code(DTC) will detect an open
or short circuit.Conditions for Setting the DTC
Engine Coolant Temperature(ECT) is higher than
80°C(176°F).
Intake Air Temperature(IAT) is higher than 15°C
(59°F).
Manifold Absolute Pressure is greater than 75kPA.
The EEGR is higher than 3%.
Mass Air Flow is between 92 ~157mg/tdc.
Engine Speed Is Between 2,500~2,900rpm.
DTCs P0107, P0108, P0112, P0113, P0117, P0118,
P0122, P0123, P0131, P0300, P0335, P0336,
P0341, P0342, P1671, P1672, P1673 are NOT SET.
Action Taken When the DTC Sets
The Malfunction Indicator Lamp (MIL) will illuminate.
The ECM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Freeze Frame and Failure Records buffers.
A history DTC is stored.
Conditions for Clearing the MIL/DTC
The MIL will turn off after four consecutive ignition
cycles in which the diagnostic runs without a fault.
A history DTC will clear after 40 consecutive warm-up
cycles without a fault.
DTC(s) can be cleared by using the scan tool.
1F–186 ENGINE CONTROLS
DAEWOO M-150 BL2
MAA1F230
DIAGNOSTIC TROUBLE CODE (DTC) – P1402 ELECTRIC EXHAUST GAS
RECIRCULATION BLOCKED
Circuit Description
An Electric Exhaust Gas Re-circulation (EEGR) system
is used to lower oxides of nitrogen (NOX) emission lev-
els caused by high combustion temperatures. It a ac-
complishes this by feeding small amounts of exhaust
gases back into the combustion chamber. When the air/
fuel mixture is diluted with the exhaust gases, combus-
tion temperatures are reduced.
A EEGR valve is used on this system. The linear EEGR
valve is designed to accurately supply exhaust gases to
the engine without the use of intake manifold vacuum.
The valve controls exhaust flow going into the intake
manifold from the exhaust manifold fhrough an orifice
with a engine control module(ECM) controlled pintle.
The ECM controls the pintle position using inputs from
the Throttle Position (TP) and the Manifold Absolute
Pressure (MAP) sensor. The ECM then commands the
EEGR valve to operate when necessary by controlling
an ignition signal through the ECM. This can be moni-
tored on a scan tool as the Desired EEGR position.
The ECM monitors the results of its command through a
feedback signal. By sending a 5 volt reference and a
ground to the EEGR valve, a voltage signal representing
the EEGR valve pintle position is sent to the ECM. This
feedback signal can also be monitored on a scan tool
and is the actual position of the EEGR pintle. The actual
EEGR position should always be near the commanded
or Desired EEGR position.
ThisDiagnostic Trouble Code(DTC) will detect an open
or short circuit.
Conditions for Setting the DTC
Engine Coolant Temperature(ECT) is greater than
80°C(176°F).Intake Air Temperature(IAT) is greater than 15°C
(59°F).
Manifold Absolute Pressure is greater than 75kPA.
The EEGR differential rate is less than 3%.
Mass Air Flow is between 92 ~157mg/tdc.
Engine Speed Is Between 2,500~2,900rpm.
DTCs P0107, P0108, P0112, P0113, P0117, P0118,
P0122, P0123, P0131, P0300, P0335, P0336,
P0341, P0342, P1671, P1672, P1673 are NOT SET.
EEGR is disabled.
Action Taken When the DTC Sets
The Malfunction Indicator Lamp (MIL) will illuminate.
The ECM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Freeze Frame and Failure Records buffers.
A history DTC is stored.
Conditions for Clearing the MIL/DTC
The MIL will turn off after four consecutive ignition
cycles in which the diagnostic runs without a fault.
A history DTC will clear after 40 consecutive warm-up
cycles without a fault.
DTC(s) can be cleared by using the scan tool.
Diagnostic Aids
Due to moisture associated with exhaust systems, the
EEGR valve may freeze and stick in cold weather at
times. After the vehicle is brought into a warm shop for
repairs, the valve warms and the problem disappears.
By watching the Actual EEGR and desired EEGR posi-
tions on a cold vehicle with a scan tool, the fault can be
1F–188 ENGINE CONTROLS
DAEWOO M-150 BL2
MAA1F230
DIAGNOSTIC TROUBLE CODE (DTC) – P1403 ELECTRIC EXHAUST GAS
RECIRCULATION VALVE FAILURE
Circuit Description
An Electric Exhaust Gas Re-circulation (EEGR) system
is used to lower oxides of nitrogen (NOX) emission lev-
els caused by high combustion temperatures. It a ac-
complishes this by feeding small amounts of exhaust
gases back into the combustion chamber. When the air/
fuel mixture is diluted with the exhaust gases, combus-
tion temperatures are reduced.
A linear EEGR valve is used on this system. The linear
EEGR valve is designed to accurately supply exhaust
gases to the engine without the use of intake manifold
vacuum. The valve controls exhaust flow going into the
intake manifold from the exhaust manifold fhrough an
orifice with a engine control module(ECM) controlled
pintle. The ECM controls the pintle position using inputs
from the Throttle Position (TP) and the Manifold Abso-
lute Pressure (MAP) sensor. The ECM then commands
the EEGR valve to operate when necessary by control-
ling an ignition signal through the ECM. This can be
monitored on a scan tool as the Desired EEGR position.
The ECM monitors the results of its command through a
feedback signal. By sending a 5 volt reference and a
ground to the EEGR valve, a voltage signal representing
the EEGR valve pintle position is sent to the ECM. This
feedback signal can also be monitored on a scan tool
and is the actual position of the EEGR pintle. The actual
EEGR position should always be near the commanded
or Desired EEGR position.
ThisDiagnostic Trouble Code(DTC) will detect an open
or short circuit.
Conditions for Setting THE DTC
Engine Coolant Temperature(ECT) is greater than
80°C(176°F).Intake Air Temperature(IAT) is greater than 15°C
(59°F).
Manifold Absolute Pressure is greater than 75kPA.
The open EEGR value is higher than 3%.
Mass Air Flow is between 92 ~157mg/tdc.
Engine Speed Is Between 2,500~2,900rpm.
EEGR potentiometer voltage is less than 0.4V.
EEGR potentiometer voltage is higher than 1.75V or
integral term of EEGR controller blocked in high or
low limit.
DTCs P0107, P0108, P0112, P0113, P0117, P0118,
P0122, P0123, P0131, P0300, P0335, P0336,
P0341, P0342, P1671, P1672, P1673 are NOT SET.
Action Taken When the DTC Sets
The Malfunction Indicator Lamp (MIL) will illuminate.
The ECM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Freeze Frame and Failure Records buffers.
A history DTC is stored.
Conditions for Clearing the MIL/DTC
The MIL will turn off after four consecutive ignition
cycles in which the diagnostic runs without a fault.
A history DTC will clear after 40 consecutive warm-up
cycles without a fault.
DTC(s) can be cleared by using the scan tool.
Diagnostic Aids
Due to moisture associated with exhaust systems, the
EEGR valve may freeze and stick in cold weather at
times. After the vehicle is brought into a warm shop for
1F–192 ENGINE CONTROLS
DAEWOO M-150 BL2
MAA1F230
DIAGNOSTIC TROUBLE CODE (DTC) – P0404 ELECTRIC EXHAUST GAS
RECIRCULATION OPENED
Circuit Description
An Electric Exhaust Gas Re-circulation (EEGR) system
is used to lower oxides of nitrogen (NOX) emission lev-
els caused by high combustion temperatures. It a ac-
complishes this by feeding small amounts of exhaust
gases back into the combustion chamber. When the air/
fuel mixture is diluted with the exhaust gases, combus-
tion temperatures are reduced.
A linear EEGR valve is used on this system. The linear
EEGR valve is designed to accurately supply exhaust
gases to the engine without the use of intake manifold
vacuum. The valve controls exhaust flow going into the
intake manifold from the exhaust manifold fhrough an
orifice with a engine control module(ECM) controlled
pintle. The ECM controls the pintle position using inputs
from the Throttle Position (TP) and the Manifold Abso-
lute Pressure (MAP) sensor. The ECM then commands
the EEGR valve to operate when necessary by control-
ling an ignition signal through the ECM. This can be
monitored on a scan tool as the Desired EEGR position.
The ECM monitors the results of its command through a
feedback signal. By sending a 5 volt reference and a
ground to the EEGR valve, a voltage signal representing
the EEGR valve pintle position is sent to the ECM. This
feedback signal can also be monitored on a scan tool
and is the actual position of the EEGR pintle. The actual
EEGR position should always be near the commanded
or Desired EEGR position.
ThisDiagnostic Trouble Code(DTC) will detect an open
or short circuit.Conditions for Setting THE DTC
EEGR circuit low voltage.
Action Taken When the DTC Sets
The Malfunction Indicator Lamp (MIL) will illuminate.
The ECM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Freeze Frame and Failure Records buffers.
A history DTC is stored.
EEGR is disabled.
Conditions for Clearing the MIL/DTC
The MIL will turn off after four consecutive ignition
cycles in which the diagnostic runs without a fault.
A history DTC will clear after 40 consecutive warm-up
cycles without a fault.
DTC(s) can be cleared by using the scan tool.
Diagnostic Aids
Due to moisture associated with exhaust systems, the
EEGR valve may freeze and stick in cold weather at
times. After the vehicle is brought into a warm shop for
repairs, the valve warms and the problem disappears.
By watching the Actual EEGR and desired EEGR posi-
tions on a cold vehicle with a scan tool, the fault can be
easily verified. Check the Freeze Frame data to deter-
mine if the DTC set when the vehicle was cold by view-
ing the Engine Coolant Temperature (ECT).
1F–196 ENGINE CONTROLS
DAEWOO M-150 BL2
MAA1F230
DIAGNOSTIC TROUBLE CODE (DTC) – P1404 ELECTRIC EXHAUST GAS
RECIRCULATION CLOSED
Circuit Description
An Electric Exhaust Gas Re-circulation (EEGR) system
is used to lower oxides of nitrogen (NOX) emission lev-
els caused by high combustion temperatures. It a ac-
complishes this by feeding small amounts of exhaust
gases back into the combustion chamber. When the air/
fuel mixture is diluted with the exhaust gases, combus-
tion temperatures are reduced.
A linear EEGR valve is used on this system. The linear
EEGR valve is designed to accurately supply exhaust
gases to the engine without the use of intake manifold
vacuum. The valve controls exhaust flow going into the
intake manifold from the exhaust manifold fhrough an
orifice with a engine control module(ECM) controlled
pintle. The ECM controls the pintle position using inputs
from the Throttle Position (TP) and the Manifold Abso-
lute Pressure (MAP) sensor. The ECM then commands
the EEGR valve to operate when necessary by control-
ling an ignition signal through the ECM. This can be
monitored on a scan tool as the Desired EEGR position.
The ECM monitors the results of its command through a
feedback signal. By sending a 5 volt reference and a
ground to the EEGR valve, a voltage signal representing
the EEGR valve pintle position is sent to the ECM. This
feedback signal can also be monitored on a scan tool
and is the actual position of the EEGR pintle. The actual
EEGR position should always be near the commanded
or Desired EEGR position.
ThisDiagnostic Trouble Code(DTC) will detect an open
or short circuit.Conditions for Setting THE DTC
EEGR circuit high voltage.
Action Taken When The DTCs Sets
The Malfunction Indicator Lamp (MIL) will illuminate.
The ECM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Freeze Frame and Failure Records buffers.
A history DTC is stored.
EEGR is disabled.
Conditions for Clearing the MIL/DTC
The MIL will turn off after four consecutive ignition
cycles in which the diagnostic runs without a fault.
A history DTC will clear after 40 consecutive warm-up
cycles without a fault.
DTC(s) can be cleared by using the scan tool.
Disconnecting the ECM battery feed for more than 10
seconds.
Diagnostic Aids
Due to moisture associated with exhaust systems, the
EEGR valve may freeze and stick in cold weather at
times. After the vehicle is brought into a warm shop for
repairs, the valve warms and the problem disappears.
By watching the Actual EEGR and desired EEGR posi-
tions on a cold vehicle with a scan tool, the fault can be
easily verified. Check the Freeze Frame data to deter-
mine if the DTC set when the vehicle was cold by view-
ing the Engine Coolant Temperature (ECT).
1F–200 ENGINE CONTROLS
DAEWOO M-150 BL2
MAA1F230
DIAGNOSTIC TROUBLE CODE (DTC) – P0405 EEGR PINTLE POSITION
SENSOR LOW VOLTAGE
Circuit Description
An Electric Exhaust Gas Re-circulation (EEGR) system
is used to lower oxides of nitrogen (NOX) emission lev-
els caused by high combustion temperatures. It a ac-
complishes this by feeding small amounts of exhaust
gases back into the combustion chamber. When the air/
fuel mixture is diluted with the exhaust gases, combus-
tion temperatures are reduced.
A linear EEGR valve is used on this system. The linear
EEGR valve is designed to accurately supply exhaust
gases to the engine without the use of intake manifold
vacuum. The valve controls exhaust flow going into the
intake manifold from the exhaust manifold fhrough an
orifice with a engine control module(ECM) controlled
pintle. The ECM controls the pintle position using inputs
from the Throttle Position (TP) and the Manifold Abso-
lute Pressure (MAP) sensor. The ECM then commands
the EEGR valve to operate when necessary by control-
ling an ignition signal through the ECM. This can be
monitored on a scan tool as the Desired EEGR position.
The ECM monitors the results of its command through a
feedback signal. By sending a 5 volt reference and a
ground to the EEGR valve, a voltage signal representing
the EEGR valve pintle position is sent to the ECM. This
feedback signal can also be monitored on a scan tool
and is the actual position of the EEGR pintle. The actual
EEGR position should always be near the commanded
or Desired EEGR position.
ThisDiagnostic Trouble Code(DTC) will detect an open
or short circuit.Conditions for Setting THE DTC
EEGR voltage is less than 0.01V.
EEGR potentiometer circuit low voltage.
Action Taken When The DTCs Sets
The Malfunction Indicator Lamp (MIL) will illuminate.
The ECM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Freeze Frame and Failure Records buffers.
A history DTC is stored.
EEGR is disabled.
Conditions for Clearing the MIL/DTC
The MIL will turn off after four consecutive ignition
cycles in which the diagnostic runs without a fault.
A history DTC will clear after 40 consecutive warm-up
cycles without a fault.
DTC(s) can be cleared by using the scan tool.
Disconnecting the ECM battery feed for more than 10
seconds.
Diagnostic Aids
Due to moisture associated with exhaust systems, the
EEGR valve may freeze and stick in cold weather at
times. After the vehicle is brought into a warm shop for
repairs, the valve warms and the problem disappears.
By watching the Actual EEGR and desired EEGR posi-
tions on a cold vehicle with a scan tool, the fault can be
easily verified. Check the Freeze Frame data to deter-
mine if the DTC set when the vehicle was cold by view-
ing the Engine Coolant Temperature (ECT).