Page 1660 of 3833
EC-1310
[QR20(WITHOUT EURO-OBD)]
HO2S1 HEATER
3. DETECT MALFUNCTIONING PART
Check the following.
●Harness connectors E60, F36
●Fuse block (J/B) connector E103
●10A fuse
●Harness for open or short between heated oxygen sensor 1 and fuse
>> Repair harness or connectors.
4. CHECK HO2S1 OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch “OFF”.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 2 and HO2S1 terminal 1.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK HEATED OXYGEN SENSOR 1 HEATER
Refer to EC-1311, "
Component Inspection" .
OK or NG
OK >> GO TO 6.
NG >> Replace heated oxygen sensor 1.
6. CHECK INTERMITTENT INCIDENT
Refer to EC-1192, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END Continuity should exist.
Page 1663 of 3833
HO2S2 HEATER
EC-1313
[QR20(WITHOUT EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
Wiring DiagramEBS00N8S
TBWA0077E
Page 1665 of 3833
![NISSAN X-TRAIL 2001 Service Repair Manual HO2S2 HEATER
EC-1315
[QR20(WITHOUT EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
4.CHECK HO2S2 OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch “OFF”.
2. Disconnect ECM harness connector.
3 NISSAN X-TRAIL 2001 Service Repair Manual HO2S2 HEATER
EC-1315
[QR20(WITHOUT EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
4.CHECK HO2S2 OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch “OFF”.
2. Disconnect ECM harness connector.
3](/manual-img/5/57405/w960_57405-1664.png)
HO2S2 HEATER
EC-1315
[QR20(WITHOUT EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
4.CHECK HO2S2 OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch “OFF”.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 4 and HO2S2 terminal 1.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 5.
NG >> Repair harness or connectors.
5.CHECK HEATED OXYGEN SENSOR 2 HEATER
Refer to EC-1315, "
Component Inspection" .
OK or NG
OK >> GO TO 6.
NG >> Replace heated oxygen sensor 2.
6.CHECK INTERMITTENT INCIDENT
Refer to EC-1192, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionEBS00N8U
HEATED OXYGEN SENSOR 2 HEATER
1. Check resistance between HO2S2 terminals as follows.
2. If NG, replace heated oxygen sensor 2.
CAUTION:
●Discard any heated oxygen sensor which has been dropped
from a height of more than 0.5 m (19.7 in) onto a hard sur-
face such as a concrete floor; use a new one.
●Before installing new oxygen sensor, clean exhaust system
threads using Oxygen Sensor Thread Cleaner tool J-43897-
18 or J-43897-12 and approved anti-seize lubricant.
Removal and InstallationEBS00N8V
HEATED OXYGEN SENSOR 2
Refer to EX-2, "EXHAUST SYSTEM" . Continuity should exist.
Terminal No. Resistance
1 and 4 2.3 - 4.3 Ω at 25°C (77°F)
2 and 1, 3, 4
∞Ω
(Continuity should not exist)
3 and 1, 2, 4
PBIB0542E
Page 1667 of 3833
IAT SENSOR
EC-1317
[QR20(WITHOUT EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
Wiring DiagramEBS00N8X
TBWA0073E
Page 1668 of 3833
![NISSAN X-TRAIL 2001 Service Repair Manual EC-1318
[QR20(WITHOUT EURO-OBD)]
IAT SENSOR
Diagnostic Procedure
EBS00N8Y
1. CHECK OVERALL FUNCTION
1. Turn ignition switch "ON".
2. Check voltage between ECM terminal 84 and ground with CON-
NISSAN X-TRAIL 2001 Service Repair Manual EC-1318
[QR20(WITHOUT EURO-OBD)]
IAT SENSOR
Diagnostic Procedure
EBS00N8Y
1. CHECK OVERALL FUNCTION
1. Turn ignition switch "ON".
2. Check voltage between ECM terminal 84 and ground with CON-](/manual-img/5/57405/w960_57405-1667.png)
EC-1318
[QR20(WITHOUT EURO-OBD)]
IAT SENSOR
Diagnostic Procedure
EBS00N8Y
1. CHECK OVERALL FUNCTION
1. Turn ignition switch "ON".
2. Check voltage between ECM terminal 84 and ground with CON-
SULT-II or tester.
OK or NG
OK >>INSPECTION END.
NG >> GO TO 2.
2. CHECK INTAKE AIR TEMPERATURE SENSOR POWER SUPPLY CIRCUIT
1. Turn ignition switch “OFF”.
2. Disconnect mass air flow sensor (intake air temperature sensor
is built-into) harness connector.
3. Turn ignition switch “ON”.
4. Check voltage between MAF sensor terminal 5 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair harness or connectors.
3. CHECK INTAKE AIR TEMPERATURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch “OFF”.
2. Check harness continuity between mass air flow sensor terminal 3 and engine ground.
Refer to Wiring Diagram.
3. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 4.
NG >> Repair harness or connectors.Voltage: 0.04 - 4.84V
PBIB0674E
PBIB0495E
Voltage: Approximately 5V
PBIB0066E
Continuity should exist.
Page 1671 of 3833
HO2S1
EC-1321
[QR20(WITHOUT EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
Wiring DiagramEBS00N94
TBWA0074E
Page 1673 of 3833
![NISSAN X-TRAIL 2001 Service Repair Manual HO2S1
EC-1323
[QR20(WITHOUT EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
3.CHECK HO2S1 GROUND CIRCUIT FOR OPEN AND SHORT
1. Disconnect HO2S1 harness connector.
2. Check harness continuity between HO2S1 t NISSAN X-TRAIL 2001 Service Repair Manual HO2S1
EC-1323
[QR20(WITHOUT EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
3.CHECK HO2S1 GROUND CIRCUIT FOR OPEN AND SHORT
1. Disconnect HO2S1 harness connector.
2. Check harness continuity between HO2S1 t](/manual-img/5/57405/w960_57405-1672.png)
HO2S1
EC-1323
[QR20(WITHOUT EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
3.CHECK HO2S1 GROUND CIRCUIT FOR OPEN AND SHORT
1. Disconnect HO2S1 harness connector.
2. Check harness continuity between HO2S1 terminal 3 and
ground.
Refer to Wiring Diagram.
3. Also check harness for short to power.
OK or NG
OK >> GO TO 4.
NG >> Repair open circuit or short to power in harness or con-
nectors.
4.CHECK HO2S1 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminal 92 and HO2S1 terminal 2.
Refer to Wiring Diagram.
3. Check harness continuity between ECM terminal 92 or HO2S1 terminal 2 and ground.
Refer to Wiring Diagram.
4. Also check harness for short to power.
OK or NG
OK >> GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
5.CHECK HEATED OXYGEN SENSOR 1
Refer to EC-1323, "
Component Inspection" .
OK or NG
OK >> GO TO 6.
NG >> Replace heated oxygen sensor 1.
6.CHECK INTERMITTENT INCIDENT
Refer to EC-1192, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionEBS00N96
HEATED OXYGEN SENSOR 1
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select “MANU TRIG” and adjust “TRIGGER POINT” to 100% in “DATA MONITOR” mode with CONSULT-
II. Continuity should exist.
PBIB0500E
Continuity should exist.
Continuity should not exist.
Page 1677 of 3833
HO2S2
EC-1327
[QR20(WITHOUT EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
Wiring DiagramEBS00N9B
TBWA0076E