Page 239 of 2898
2 CHECK POWER SOURCE CIRCUIT
1. Turn ignition switch to ªOFFº position.
2. Disconnect TCM harness connector.
3. Check continuity between terminal 5 and TCM harness connector terminal 3.
Continuity should exist.
SAT890JB
If OK, check harness for short to ground and short to power.
4. Reinstall any part removed.
OK or NG
OK©GO TO 3.
NG©Repair open circuit or short to ground or short to power in harness or connectors.
3 CHECK DTC
Perform Diagnostic Trouble Code (DTC) confirmation procedure, AT-234.
OK or NG
OK©INSPECTION END
NG©1. Perform TCM input/output signal inspection.
2. If NG, recheck TCM pin terminals for damage or loose connection with harness con-
nector.
DTC P0740 TORQUE CONVERTER CLUTCH
SOLENOID VALVE
EURO-OBD
Diagnostic Procedure (Cont'd)
AT-237
Page 246 of 2898
3 CHECK POWER SOURCE CIRCUIT
1. Turn ignition switch to ªOFFº position.
2. Check resistance between terminal 4 and TCM harness connector terminal 1.
Resistance:
Approx. 0W
SAT897JB
If OK, check harness for short to ground and short to power.
3. Reinstall any part removed.
OK or NG
OK©GO TO 4.
NG©Repair open circuit or short to ground or short to power in harness or connectors.
4 CHECK DTC
Perform Diagnostic Trouble Code (DTC) confirmation procedure, AT-240.
OK or NG
OK©INSPECTION END
NG©1. Perform TCM input/output signal inspection.
2. If NG, recheck TCM pin terminals for damage or loose connection with harness con-
nector.
DTC P0745 LINE PRESSURE SOLENOID VALVEEURO-OBD
Diagnostic Procedure (Cont'd)
AT-244
Page 248 of 2898

SAT322GC
DescriptionNJAT0303Shift solenoid valves A and B are turned ªONº or ªOFFº by the TCM
in response to signals sent from the PNP switch, vehicle speed and
throttle position sensors. Gears will then be shifted to the optimum
position.
Gear position1234
Shift solenoid valve A ON (Closed) OFF (Open) OFF (Open) ON (Closed)
Shift solenoid valve B ON (Closed) ON (Closed) OFF (Open) OFF (Open)
TCM TERMINALS AND REFERENCE VALUENJAT0303S01Remarks: Specification data are reference values.
Terminal
No.Wire color Item ConditionJudgement stan-
dard
11 L/WShift solenoid
valve A
When shift solenoid valve A oper-
ates.
(When driving in ªD
1ºorªD4º.)Battery voltage
When shift solenoid valve A does
not operate.
(When driving in ªD
2ºorªD3º.)1V or less
ON BOARD DIAGNOSIS LOGICNJAT0303S02
Diagnostic trouble code Malfunction is detected when ... Check items (Possible cause)
: SFT SOL A/CIRC TCM detects an improper voltage drop
when it tries to operate the solenoid
valve.+Harness or connectors
(The solenoid circuit is open or shorted.)
+Shift solenoid valve A
: P0750
DTC P0750 SHIFT SOLENOID VALVE AEURO-OBD
Description
AT-246
Page 252 of 2898
2 CHECK POWER SOURCE CIRCUIT
1. Turn ignition switch to ªOFFº position.
2. Disconnect TCM harness connector.
3. Check continuity between terminal 2 and TCM harness connector terminal 11.
Continuity should exist.
SAT901JC
If OK, check harness for short to ground and short to power.
4. Reinstall any part removed.
OK or NG
OK©GO TO 3.
NG©Repair open circuit or short to ground or short to power in harness or connectors.
3 CHECK DTC
Perform Diagnostic Trouble Code (DTC) confirmation procedure, AT-247.
OK or NG
OK©INSPECTION END
NG©1. Perform TCM input/output signal inspection.
2. If NG, recheck TCM pin terminals for damage or loose connection with harness con-
nector.
DTC P0750 SHIFT SOLENOID VALVE AEURO-OBD
Diagnostic Procedure (Cont'd)
AT-250
Page 254 of 2898

SAT322GC
DescriptionNJAT0307Shift solenoid valves A and B are turned ªONº or ªOFFº by the TCM
in response to signals sent from the PNP switch, vehicle speed and
throttle position sensors. Gears will then be shifted to the optimum
position.
Gear position1234
Shift solenoid valve A ON (Closed) OFF (Open) OFF (Open) ON (Closed)
Shift solenoid valve B ON (Closed) ON (Closed) OFF (Open) OFF (Open)
TCM TERMINALS AND REFERENCE VALUENJAT0307S01Remarks: Specification data are reference values.
Terminal
No.Wire color Item ConditionJudgement stan-
dard
12 L/YShift solenoid
valve B
When shift solenoid valve B oper-
ates.
(When driving in ªD
1ºorªD2º.)Battery voltage
When shift solenoid valve B does
not operate.
(When driving in ªD
3ºorªD4º.)1V or less
ON BOARD DIAGNOSIS LOGICNJAT0307S02
Diagnostic trouble code Malfunction is detected when ... Check items (Possible cause)
: SFT SOL B/CIRC TCM detects an improper voltage drop
when it tries to operate the solenoid
valve.+Harness or connectors
(The solenoid circuit is open or shorted.)
+Shift solenoid valve B
: P0755
DTC P0755 SHIFT SOLENOID VALVE BEURO-OBD
Description
AT-252
Page 258 of 2898
2 CHECK POWER SOURCE CIRCUIT
1. Turn ignition switch to ªOFFº position.
2. Disconnect TCM harness connector.
3. Check continuity between terminal 12 and TCM harness connector terminal 1.
Continuity should exist.
SAT905JD
If OK, check harness for short to ground and short to power.
4. Reinstall any part removed.
OK or NG
OK©GO TO 3.
NG©Repair open circuit or short to ground or short to power in harness or connectors.
3 CHECK DTC
Perform Diagnostic Trouble Code (DTC) confirmation procedure, AT-253.
OK or NG
OK©INSPECTION END
NG©1. Perform TCM input/output signal inspection.
2. If NG, recheck TCM pin terminals for damage or loose connection with harness con-
nector.
DTC P0755 SHIFT SOLENOID VALVE BEURO-OBD
Diagnostic Procedure (Cont'd)
AT-256
Page 265 of 2898

Diagnostic ProcedureNJAT0313
1 CHECK DTC WITH ECM
Perform diagnostic test mode II (self-diagnostic results) for engine control.
Refer to EC-74, ªMalfunction Indicator Lamp (MIL)º.
OK or NG
OK (With CONSULT-II)©GO TO 2.
OK (Without CONSULT-
II)©GO TO 3.
NG©Check throttle position sensor circuit for engine control. Refer to EC-207, ªDTC P0120
THROTTLE POSITION SENSORº.
2 CHECK INPUT SIGNAL (WITH CONSULT-II)
With CONSULT-II
1. Apply vacuum to the throttle opener then check the following. Refer from step 1 to 5 of ªPreparationº, ªTCM SELF-DI-
AGNOSTIC PROCEDURE (No Tools)º, AT-63.
2. Turn ignition switch to ªONº position.
(Do not start engine.)
3. Select ªECU INPUT SIGNALSº in ªDATA MONITORº mode for ªA/Tº with CONSULT-II.
SAT014K
4. Read out the value of ªTHRTL POS SENº.
Voltage:
Fully-closed throttle:
Approximately 0.5V
Fully-open throttle:
Approximately 4V
SAT614J
OK or NG
OK©GO TO 4.
NG©Check harness for short or open between ECM and TCM regarding throttle position sen-
sor circuit. (Main harness)
DTC P1705 THROTTLE POSITION SENSOREURO-OBD
Diagnostic Procedure
AT-263
Page 266 of 2898
3 CHECK INPUT SIGNAL (WITHOUT CONSULT-II)
Without CONSULT-II
1. Apply vacuum to the throttle opener then check the following. Refer to steps 1 to 5 of ªPreparationº, ªTCM SELF-DIAG-
NOSTIC PROCEDURE (No Tools)º, AT-63.
2. Turn ignition switch to ªONº position.
(Do not start engine.)
3. Check voltage between TCM terminals 41 and 42 while accelerator pedal is depressed slowly.
Voltage:
Fully-closed throttle valve:
Approximately 0.5V
Fully-open throttle valve:
Approximately 4V
(Voltage rises gradually in response to throttle position)
SAT453J
OK or NG
OK©GO TO 5.
NG©Check harness for short or open between ECM and TCM regarding throttle position sen-
sor circuit. (Main harness)
DTC P1705 THROTTLE POSITION SENSOREURO-OBD
Diagnostic Procedure (Cont'd)
AT-264