Page 2032 of 2493

NISSAN ALMERA N16 2001  Electronic Repair Manual NHA386
ELECTRICAL COMPONENTS INSPECTION=NJHA0146Fan SwitchNJHA0146S01Check continuity between terminals at each switch position.
KNOB POSITION Continuity between terminals
OFF No continuity
1 13Ð14Ð

Page 2044 of 2493

NISSAN ALMERA N16 2001  Electronic Repair Manual 14 CHECK FAN SWITCH
Refer to HA-60.
OK or NG
OK©GO TO 15.
NG©Replace fan switch.
15 CHECK BODY GROUND CIRCUIT
Check circuit continuity between heater control panel harness terminal No. 13 and body g

Page 2078 of 2493

NISSAN ALMERA N16 2001  Electronic Repair Manual Supplemental Restraint System (SRS) ªAIR
BAGº and ªSEAT BELT PRE-TENSIONERº
NJSC0001The Supplemental Restraint System such as ªAIR BAGº and ªSEAT BELT PRE-TENSIONERº used along with
a seat bel

Page 2100 of 2493

NISSAN ALMERA N16 2001  Electronic Repair Manual System DescriptionNJSC0009The alternator provides DC voltage to operate the vehicles electrical system and to keep the battery charged.
The voltage output is controlled by the IC regulator.
Power is

Page 2113 of 2493

NISSAN ALMERA N16 2001  Electronic Repair Manual ELECTRICAL SYSTEM
SECTION
EL
CONTENTS
PRECAUTIONS...............................................................4
Supplemental Restraint System (SRS)²AIR
BAG²and²SEAT BELT PRE-TENSIONER²..........

Page 2114 of 2493

NISSAN ALMERA N16 2001  Electronic Repair Manual WARNING CHIME....................................................... 113
Component Parts and Harness Connector
Location ................................................................... 113
System D

Page 2116 of 2493

NISSAN ALMERA N16 2001  Electronic Repair Manual Supplemental Restraint System (SRS) ªAIR
BAGº and ªSEAT BELT PRE-TENSIONERº
NJEL0001The Supplemental Restraint System such as ªAIR BAGº and ªSEAT BELT PRE-TENSIONERº used along with
a seat bel

Page 2134 of 2493

NISSAN ALMERA N16 2001  Electronic Repair Manual CEL083
InspectionNJEL0007FUSENJEL0007S01+If fuse is blown, be sure to eliminate cause of problem
before installing new fuse.
+Use fuse of specified rating. Never use fuse of more than
specified rating