Page 654 of 4284

Symptom:
CPA NOT ENGAGED
When Monitored and Set Condition:
CPA NOT ENGAGED
When Monitored: Continuously with the ignition on.
Set Condition: If the connector positive assurance lock is not fully engaged, the Front
Control Module will detect battery voltage on the B(+) Sense circuit. With voltage present,
the FCM determines that there is a poor connection at connector C5 of the Fuse and Relay
Center.
POSSIBLE CAUSES
FRONT CONTROL MODULE INTERNAL MALFUNCTION
FUSE AND RELAY CENTER INTERNAL MALFUNCTION
INTERMITTENT CONDITION
CONNECTOR POSITIVE ASSURANCE LOCK
TEST ACTION APPLICABILITY
1 Turn the ignition on.
With the DRBIIIt, erase the current Front Control Module DTC's.
Turn the ignition off, wait 10 seconds then turn the ignition on.
With the DRBIIIt, read the current Front Control Module DTC's.
Does the DRBIIItdisplay: CPA NOT ENGAGED?All
Ye s®Go To 2
No®The condition that caused this symptom is currently not present.
Inspect the related wiring harness for a possible intermittent
condition.
Perform BODY VERIFICATION TEST - VER 1.
2 Turn the ignition off.
Disconnect the Front Control Module from the Fuse and Relay Center.
Measure the voltage of the B(+) Sense circuit at the Fuse and Relay Center side of the
FCM connector.
Is the voltage above 10.0 volts?All
Ye s®Go To 3
No®Replace the Front Control Module.
Perform BODY VERIFICATION TEST - VER 1.
625
INTELLIGENT POWER MODULE
Page 656 of 4284

Symptom:
IGN RUN/START INPUT WIRING
When Monitored and Set Condition:
IGN RUN/START INPUT WIRING
When Monitored: With the ignition on and battery voltage greater than 10.4 volts.
Set Condition: The Fused Ignition Switch Output circuit voltage at the FCM goes below
0.5 volts.
POSSIBLE CAUSES
TEST FOR CURRENT DTC'S
FRONT CONTROL MODULE INTERNAL MALFUNCTION
FUSE AND RELAY CENTER INTERNAL MALFUNCTION
FUSED IGNITION SWITCH OUTPUT CIRCUIT OPEN
TEST ACTION APPLICABILITY
1 With the DRBIIIt, record and erase the current Front Control Module DTC's.
Cycle the ignition from ON to OFF.
Start the vehicle and observe the DRBIIIt.
With the DRBIIIt, read DTC's.
Does the DRBIIItdisplay: IGNITION RUN-START INPUT WIRING?All
Ye s®Go To 2
No®The condition that caused this DTC is currently not present. Use
the wiring diagram/schematic as a guide, and inspect the related
wiring harness for a possible intermittent condition.
Perform BODY VERIFICATION TEST - VER 1.
2 Turn the ignition off.
Disconnect the Front Control Module from the Fuse and Relay Center.
Measure the voltage of the Fused Ignition Switch Output circuit (cavity 37) at the
Fuse and Relay Center side of the FCM connector.
Turn the ignition on.
Is the voltage above 10.0 volts?All
Ye s®Replace the Front Control Module.
Perform BODY VERIFICATION TEST - VER 1.
No®Go To 3
627
INTELLIGENT POWER MODULE
Page 658 of 4284

Symptom:
IGNITION START INPUT WIRING
When Monitored and Set Condition:
IGNITION START INPUT WIRING
When Monitored: With the ignition on and battery voltage greater than 10.4 volts.
Set Condition: The Fused Ignition Switch Output (Start) circuit voltage at the FCM goes
below 0.5 volts.
POSSIBLE CAUSES
TEST FOR CURRENT DTC'S
FRONT CONTROL MODULE INTERNAL MALFUNCTION
FUSE AND RELAY CENTER INTERNAL MALFUNCTION
FUSED IGNITION SWITCH OUTPUT CIRCUIT OPEN
TEST ACTION APPLICABILITY
1 With the DRBIIIt, record and erase the current Front Control Module DTC's.
Cycle the ignition from ON to OFF.
Start the vehicle and observe the DRBIIIt.
With the DRBIIIt, read DTC's.
Does the DRBIIItdisplay: IGNITION START INPUT WIRING?All
Ye s®Go To 2
No®The condition that caused this DTC is currently not present. Use
the wiring diagram/schematic as a guide, and inspect the related
wiring harness for a possible intermittent condition.
Perform BODY VERIFICATION TEST - VER 1.
2 Turn the ignition off.
Disconnect the Front Control Module from the Fuse and Relay Center.
Measure the voltage of the Fused Ignition Switch Output circuit (cavity 37) at the
Fuse and Relay Center side of the FCM connector.
Turn the ignition on.
Is the voltage above 10.0 volts?All
Ye s®Replace the Front Control Module.
Perform BODY VERIFICATION TEST - VER 1.
No®Go To 3
629
INTELLIGENT POWER MODULE
Page 660 of 4284
Symptom:
INTERNAL DRIVER FAULT #1
When Monitored and Set Condition:
INTERNAL DRIVER FAULT #1
When Monitored: Continuously with the ignition on.
Set Condition: The Front Control Module has detected an internal malfunction of the
module.
POSSIBLE CAUSES
FRONT CONTROL MODULE INTERNAL MALFUNCTION
INTERMITTENT CONDITION
TEST ACTION APPLICABILITY
1 Turn the ignition on.
With the DRBIIIt, erase the current Front Control Module DTC's.
Turn the ignition off, wait 10 seconds then turn the ignition on.
With the DRBIIIt, read the current Front Control Module DTC's.
Does the DRBIIItdisplay: INTERNAL DRIVER FAULT #1?All
Ye s®Replace the Front Control Module.
Perform BODY VERIFICATION TEST - VER 1.
No®This symptom represents an internal malfunction in the Front
Control Module. The condition that caused this symptom is
currently not present.
Perform BODY VERIFICATION TEST - VER 1.
631
INTELLIGENT POWER MODULE
Page 661 of 4284
Symptom:
INTERNAL DRIVER FAULT #2
When Monitored and Set Condition:
INTERNAL DRIVER FAULT #2
When Monitored: Continuously with the ignition on.
Set Condition: The Front Control Module has detected an internal malfunction of the
module.
POSSIBLE CAUSES
FRONT CONTROL MODULE INTERNAL MALFUNCTION
INTERMITTENT CONDITION
TEST ACTION APPLICABILITY
1 Turn the ignition on.
With the DRBIIIt, erase the current Front Control Module DTC's.
Turn the ignition off, wait 10 seconds then turn the ignition on.
With the DRBIIIt, read the current Front Control Module DTC's.
Does the DRBIIItdisplay: INTERNAL DRIVER FAULT #2?All
Ye s®Replace the Front Control Module.
Perform BODY VERIFICATION TEST - VER 1.
No®This symptom represents an internal malfunction in the Front
Control Module. The condition that caused this symptom is
currently not present.
Perform BODY VERIFICATION TEST - VER 1.
632
INTELLIGENT POWER MODULE
Page 662 of 4284
Symptom:
INTERNAL DRIVER FAULT #3
When Monitored and Set Condition:
INTERNAL DRIVER FAULT #3
When Monitored: Continuously with the ignition on.
Set Condition: The Front Control Module has detected an internal malfunction of the
module.
POSSIBLE CAUSES
FRONT CONTROL MODULE INTERNAL MALFUNCTION
INTERMITTENT CONDITION
TEST ACTION APPLICABILITY
1 Turn the ignition on.
With the DRBIIIt, erase the current Front Control Module DTC's.
Turn the ignition off, wait 10 seconds then turn the ignition on.
With the DRBIIIt, read the current Front Control Module DTC's.
Does the DRBIIItdisplay: INTERNAL DRIVER FAULT #3?All
Ye s®Replace the Front Control Module.
Perform BODY VERIFICATION TEST - VER 1.
No®This symptom represents an internal malfunction in the Front
Control Module. The condition that caused this symptom is
currently not present.
Perform BODY VERIFICATION TEST - VER 1.
633
INTELLIGENT POWER MODULE
Page 664 of 4284

Symptom:
DOME SWITCH INPUT OPEN
When Monitored and Set Condition:
DOME SWITCH INPUT OPEN
When Monitored: Dome Lamps Off.
Set Condition: When Voltage is below 4.8 volts for 62.5 msec.
POSSIBLE CAUSES
HEADLAMP SWITCH MUX RETURN CIRCUIT OPEN
PANEL LAMPS DIMMER SIGNAL CIRCUIT OPEN
BODY CONTROL MODULE
HEADLAMP SWITCH
TEST ACTION APPLICABILITY
1 Turn the ignition on.
With the DRBIIIt, clear all BCM DTC's.
Turn the Dome Lamps on.
With the DRBIIIt, read the DTC information.
Does the DRBIIItdisplay: Dome Switch Input Open?All
Ye s®Go To 2
No®Repair the Headlamp Switch MUX Return Circuit for an open
condition.
Perform BODY VERIFICATION TEST - VER 1.
2 Turn the ignition off.
Disconnect the Body Control Module harness connector.
Disconnect the Headlamp Switch harness connector.
Measure the resistance of the Panel Lamps Dimmer Signal Circuit.
Is the resistance below 5.0 ohms?All
Ye s®Go To 3
No®Repair the Panel Lamps Dimmer Signal Circuit for an open
condition.
Perform BODY VERIFICATION TEST - VER 1.
3 Turn the ignition off.
Disconnect the Headlamp Switch harness connector.
Disconnect the Body Control Module harness connector.
Measure the voltage of the Headlamp Switch MUX Return Circuit.
Is the voltage below 4.8 volts?All
Ye s®Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
No®Replace the Headlamp Switch.
Perform BODY VERIFICATION TEST - VER 1.
635
INTERIOR LIGHTING
Page 670 of 4284

Symptom:
READING LAMP OUTPUT SHORT
When Monitored and Set Condition:
READING LAMP OUTPUT SHORT
When Monitored: Anytime the Body Control Module is active.
Set Condition: When output voltage status is LOW.
POSSIBLE CAUSES
READING LAMPS DRIVER CIRCUIT SHORT
COURTESY LAMPS DRIVER READING LAMPS CIRCUIT SHORT TO GROUND
BODY CONTROL MODULE
TEST ACTION APPLICABILITY
1 Turn the ignition on.
With the DRBIIIt, clear all BCM DTC's.
Turn the reading lamps on.
With the DRBIIIt, read the DTC information.
Does then DRBIIItdisplay : Reading Lamps Output Short?All
Ye s®Go To 2
No®Repair the Reading Lamps Driver Circuit for a short condition.
Perform BODY VERIFICATION TEST - VER 1.
2 Turn the ignition off.
Disconnect the Body Control Module C2 harness connector
Measure the resistance of the Courtesy Lamps Driver Reading Lamps Circuit.
Is the resistance below 5.0 ohms?All
Ye s®Repair the Courtesy Lamps Driver Reading Lamps Circuit for a
short to ground.
Perform BODY VERIFICATION TEST - VER 1.
No®Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
641
INTERIOR LIGHTING