YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-15
AMBIENT TEMPERATURE WITHIN 30 ± 35C (85 ± 95F)
CONDITION
MANIFOLD
GAUGEMPa
(kg/cm2)
(psi)DETAILCAUSECORRECTION
LoHi
0.23 ± 0.35
(2.3 ± 3.5)
(33 ± 50)1.4 ± 1.75
(14 ± 17.5)
(200 ± 249)
Normal condition.ÐÐÐÐ
Negative
pressure0.5 ± 0.6
(5 ± 6)
(71.2 ± 85.3)
The low pressure side
reads a negative pressure,
and the high pressure side
reads an extremely low
pressure.
Presence of frost around
tubing to and from receiver /
dryer and expansion valve. Dust particles or water
droplets are either stuck or
frozen inside expansion
valve, preventing the
refrigerant from flowing.Clean expansion valve.
Replace it if it cannot be
cleaned.
Replace receiver / dryer.
Evacuate the A / C
system and recharge
with fresh refrigerant.
Normal:
0.23 ± 0.35
(2.3 ± 3.5)
(33 ± 50)
Abnormal:
Negative
pressureNormal:
1.4 ± 1.75
(14 ± 17.5)
(200 ± 249)
Abnormal:
0.69 ± 0.98
(7 ± 10)
(100 ± 142) During A / C operation, the
low pressure side
sometimes indicates
negative pressure, and
sometimes normal
pressure. Also high
pressure side reading
fluctuates between the
abnormal and normal
pressure.Expansion valve is frozen
due to moisture in the
system, and temporarily
shuts off the refrigeration
cycle.Replace expansion
valve.
Replace receiver / dryer.
Evacuate A / C system
and recharge with fresh
refrigerant.
0.05 ± 0.15
(0.5 ± 1.5)
(4.2 ± 21.3)
0.69 ± 0.98
(7 ± 10)
(100 ± 142)
Both low and high pressure
sides indicate low readings.
Continuous air bubbles are
visible through sight glass.
Output air is slightly cold.Insufficient refrigerant in
system. (Refrigerant
leaking)Using a gas leak
detector, check for leaks
and repair as necessary.
Recharge refrigerant to a
specified amount.
If the pressure reading is
almost 0 when the
manifold gauges are
attached, check for any
leaks, repair them, and
evacuate the system.
0.4 ± 0.6
(4 ± 6)
(56.9 ± 85.3)
Pressure on low pressure
side is high.
Pressure on high pressure
side is low.
Both pressure becoming
equal right after A / C is
turned OFF.Internal leak in compressor.Inspect compressor and
repair or replace as
necessary.
035 045
High pressure reading on
both low and high pressure
sides.
Air bubbles are not visible
even when engine rpm is
lowered.Overcharged A / C system.
Faulty condenser cooling
operation.
Faulty condenser fan
operation.Adjust refrigerant to
specified amount.
Clean condenser.
Inspect and repair
condenser fan.
0.35 ± 0.45(3.5 ± 4.5)
(50 ± 64)
1.96 ± 2.45
(20 ± 25)
(285 ± 355)
High pressure reading on
both low and high pressure
sides.
Low pressure side tubing is
not cold when touched.
Air bubbles are visible
through sight glass.Presence of air in A / C
system. (Improperly
evacuated)Replace receiver / dryer.
Inspect quantity of
compressor oil and
presence of
contaminants in oil.
Evacuate system and
recharge with fresh
refrigerant.
0.45 ± 0.55
(4.5 ± 5.5)
(64 ± 78)
High pressure reading on
both low and high pressure
sides.
Large amount of frost or
dew on the low pressure
side tubing.Faulty expansion valve.
Refrigerant flow is not
regulated properly.Replace expansion
valve.
YH4
GRAND
VITARA
Fig. A
Fig. B
Fig. C
C51-3-6 For G16
and J20 engines
C51-3-25 For
H25 engine
1B-18 AIR CONDITIONING (OPTIONAL)
INSPECTION OF A / C CONTROLLER AND ITS
CIRCUITS
CAUTION:
A / C controller and ECM cannot be checked by itself.
It is strictly prohibited to connect voltmeter or ohmmeter to
A / C controller and ECM with couplers disconnected from it.
A / C controller (1) and its circuits can be checked at A / C controller
wiring couplers by measuring voltage.
Voltage Check
1) Remove A / C controller (1) from vehicle (refer to ªA / C CON-
TROLLER REMOVALº in this section).
2) Remove ECM (2) from vehicle.
3) Connect A / C controller couplers to A / C controller and connect
ECM couplers to ECM.
4) Check each terminal voltage with couplers connected by refer-
ing to the A / C CONTROLLER VOLTAGE VALUES TABLE the
later.
YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-21
TerminalWireCircuitMeasurement
groundNormal valueCondition
AC2-1L/YSensor groundGround to body
(Fig. A)± 0.4 ± 0 voltEngine running
1.5 volts
(3150 )Evaporator thermistor temperature at
approx. 15C (59F) with engine
running
AC2-2W/B
Evaporator
thermistor
temperature
(evaporator temp.
sensor) input
Ground to engine
(Fig. B)
2.62 volts
(6.311 )
Evaporator thermistor temperature at
approx. 1C (34F) with engine
running
* If the temperature is less than
approx. 1C, in this case
compressor and condenser fan
should be stop (come back at more
than approx. 2.5C (less than
5840 , 2.5 V))
H25
engine
E61-27 /
G16 J20Gr/W
Signal output to
A / C controller
(A / C ON
Ground to engine
(Fig C)
10 ± 14 volts
Required A / C ON (terminal AC-A13)
at engine running with normal
condition (refer to ªINSPECTION OF
ECM AND ITS CIRCUITº in Section
6E)
G16, J20
engines
E61-8
(
permission
signal)(Fig. C)
0 ± 1 volt
Except the above-mentioned with
engine running
In this case compressor should be
stop
H25
engine
E61-28 /
Y/B
Signal input from
A / C controller
Ground to engine
0 ± 1.5 voltsRequire A / C ON
G16, J20
engines
E61-17Y/B(A / C ON request
signal)
g
(Fig. C)
10 ± 14 voltsTurn off the A / C
H25
engine
E61-5 /
G16, J20
engines
E61-22
Y/L
A / C condenser
cooling fan relay
outputGround to engine
(Fig. C)0 ± 1 volt
Blower fan motor switch and A / C or
defroster position switch (see
NOTE) ON with engine running at
evaporator thermistor temperature
input more than approx. 2.5C (less
than 2.5 V (5840 )), refrigerant
pressure switch ON and signal
input from ECM ON
Engine coolant temperature sensor
more than 113C (236F) with
engine running
10 ± 14 voltsExcept the above-mentioned with
engine running
NOTE:
Defroster position switch circuit is equipped with LH vehicle only.
YH4
GRAND
VITARA
J20 engine
H25 engine G16 engine
1. Generator belt
2. Compressor drive belt3. Compressor pulley
4. Crankshaft pulley
1B-22 AIR CONDITIONING (OPTIONAL)
DRIVE BELT
INSPECTION
For G16 and H25 engines
Refer to Section 3B1 for details.
For J20 engine
Refer to Section 6H for details.
YH4
GRAND
VITARA
Charge 440 50 g, 14.2 1.9 oz of
refrigerant in gas form
AIR CONDITIONING (OPTIONAL) 1B-23
REFRIGERANT RECOVERY, EVACUATION AND CHARGING
WARNING:
Your eyes should not be exposed to refrigerant (liquid).
Any liquid Refrigerant-134a escaping by accident shows a temperature as low as approx. ± 6C
(42.8F) below freezing point. Should liquid HFC-134a (R-134a) get into your eyes, it may cause a seri-
ous injury. To protect your eyes against such accident, it is necessary to always wear goggles. Should
it occur that HFC-134a (R-134a) strikes your eye(s), consult a doctor immediately.
± DO NOT USE YOUR HAND TO RUB THE AFFECTED EYE(S). INSTEAD, use quantities of fresh cold
water to splash it over the affected area to gradually raise temperature of such area above freezing
point.
± Obtain proper treatment as soon as possible from a doctor or eye specialist.
Should the HFC-134a (R-134a) liquid come into contact with your skin, the affected area should be
treated in the same manner as when skin is frostbitten or frozen.
Refrigerant must not be handled near where welding or steam cleaning is performed.
Refrigerant should be kept at a cold and dark place. It should never be stored where a high tempera-
ture is anticipated, e.g. where exposed to direct sun light, close to fire or inside vehicle (including
trunk room).
Avoid breathing fumes produced when HFC-134a (R-134a) is burned. Such fumes may be hazardous
to health.
OPERATION PROCEDURE FOR CHARGING A / C WITH REFRIGERANT
YH4
GRAND
VITARA
For CAMI production vehicle
For IWATA production vehicle
1B-24 AIR CONDITIONING (OPTIONAL)
RECOVERY
NOTE:
When discharging refrigerant out of A / C system, always re-
cover it by using refrigerant recovery and recycling equip-
ment (1). Discharging it into atmosphere would cause ad-
verse effect to environments.
When handling recovery and recycling equipment, be sure
to follow the instruction manual for the equipment.
YH4
GRAND
VITARA
For CAMI production vehicle
For IWATA production vehicle
AIR CONDITIONING (OPTIONAL) 1B-25
EVACUATING
EVACUATING PROCEDURE
CAUTION:
Do not evacuate before recovering refrigerant in system.
NOTE:
Whenever opened (exposed to atmospheric air), air condition-
ing system must be evacuated by using a vacuum pump. The
A / C system should be attached with a manifold gauge set, and
should be evacuated for approx. 15 minutes.
1) Connect high charging hose (1) and low charging hose (2) of
manifold gauge set (3) respectively as follows:
High Charging Hose (1)
High pressure charging valve (4)
on Discharge Hose
Low Charging Hose (2)i
Low pressure charging valve (5)
on Suction Pipe
2) Attach center charging hose (6) of manifold gauge set (3) to vac-
uum pump (7).
3) Operate vacuum pump (7), and then open discharge-side valve
(9) (Hi) of manifold gauge set (3).
If there is no blockage in the system, there will be an indication
on high pressure gauge (10).
When this occurs, open the other-side valve (8) (Lo) of the set.
4) Approx. 10 minutes later, low pressure gauge (11) should show
a vacuum lower than ± 760 mmHg providing no leakage exists.
NOTE:
If the system does not show a vacuum below ± 760 mmHg,
close both valves, stop vacuum pump and watch move-
ment of low pressure gauge.
Increase in the gauge reading suggests existence of leak-
age. In this case, repair the system before continuing its
evacuation.
If the gauge shows a stable reading (suggesting no leak-
age), continue evacuation.
5) Evacuation should be carried out for a total of at least 15 minutes.
6) Continue evacuation until low pressure gauge indicates a vacu-
um less than ± 760 mmHg, and then close both valves (8), (9).
7) Stop vacuum pump (7). Disconnect center charging hose (6) from
pump inlet. Now, the system is ready for charging refrigerant.
CHECKING SYSTEM FOR PRESSURE LEAKS
After completing the evacuation, close manifold gauge high pres-
sure valve (HI) and low-pressure valve (LO) and wait 10 minutes.
Verify that low-pressure gauge reading has not changed.
CAUTION:
If the gauge reading moves closer to ª0º, there is a leak
somewhere. Inspect the tubing connections, make neces-
sary corrections, and evacuate system once again, making
sure that there are no leaks.
YH4
GRAND
VITARA
For CAMI production vehicle
For IWATA production vehicle
1B-26 AIR CONDITIONING (OPTIONAL)
CHARGING
CAUTION:
ALWAYS CHARGE THROUGH LOW PRESSURE-SIDE of A / C system at after the initial charging is per-
formed from the high-pressure side with the engine stopped.
NEVER CHARGE TO HIGH PRESSURE-SIDE of A / C system with engine running.
Do not charge while compressor is hot.
When installing tap valve to refrigerant container to make a hole there through, carefully follow direc-
tions given by manufacturer.
A pressure gauge should always be used before and during charging.
The refrigerant container should be emptied of refrigerant when discarding it.
The refrigerant container should not be heated up to 40C (104F) or over.
Refrigerant container should not be reversed in direction during charging. Reversing in direction
causes liquid refrigerant to enter compressor, causing troubles, such as compression of liquid refrig-
erant and the like.
NOTE:
The air conditioning system contains HFC-134a (R-134a).
Described here is a method to charge the air conditioning system with refrigerant from the refrigerant ser-
vice container.
When charging refrigerant recovered by using the refrigerant and recycling equipment (when recycling
refrigerant), follow the procedure described in the equipment manufacturer's instruction manual.
The initial charging of the A / C system is performed from the high-
pressure side with the engine stopped.
And next, this method must be followed by charging from the low-
pressure side with the engine running.
1) Check to make sure that hoses are routed properly after eva-
cuating the system.
2) Connect Low-side hose (1) and High side hose (2) of the man-
ifold gauge set (3) in position. Thus open refrigerant container
valve (4) to purge the charging line.
3) Open the high-pressure side valve (6) and charge refrigerant to
system.
4) After a while, open the low-pressure side valve (5) and close the
high-pressure side valve (6).
WARNING:
Make sure that high pressure-side valve is closed se-
curely.
5) Start engine and keep engine speed at 1500 r / min. Then, oper-
ate air conditioning.
6) Charge A / C system with refrigerant in vapor state. At this time,
refrigerant container should be held upright.