YH4
GRAND
VITARA
0A-24 GENERAL INFORMATION
Self-lock
nut
STANDARD TIGHTENING TORQUE
Each fastener should be tightened to the torque specified in each section of this manual. If no description or specifi-
cation is provided, refer to the following tightening torque chart for the applicable torque for each fastener. When
a fastener of greater strength than the original one is used, however, use the torque specified for the original fasten-
er.
NOTE:
For the flanged bolt, flanged nut and self-lock nut of 4T and 7T strength, add 10% to the tightening torque
given in the chart below.
The chart below is applicable only where the fastened parts are made of steel or light alloy.
Tightening torque chart
Thread Diameter (Nominal Diameter)
(mm)
45681012141618
Strength
45681012141618
A equivalent of 4T strength
fastenerN.m1.53.05.513294565105160
kg-m0.150.300.551.32.94.56.510.516
lb-ft1.02.54.09.521.032.547.076.0116.0
A equivalent of 6.8 strength
fastener without flan
geN.m2.44.78.4204280125193280g
kg-m0.240.470.842.04.28.012.519.328
lb-ft2.03.56.014.530.558.090.5139.5202.5
A equivalent of 6.8 strength
fastener with flan
geN.m2.44.98.8214484133203298g
kg-m0.240.490.882.14.48.413.320.329.8
lb-ft2.03.56.515.532.061.096.5147.0215.5
A equivalent of 7T strength
fastenerN.m2.34.510235085135210240
kg-m0.230.451.02.35.08.513.52124
lb-ft2.03.57.517.036.561.598.0152.0174.0
A equivalent of 8.8 strength
fastener without flan
geN.m3.16.3112756105168258373g
kg-m0.310.631.12.75.610.516.825.837.3
lb-ft2.54.58.019.540.576.0121.5187.0270.0
A equivalent of 8.8 strength
fastener with flan
geN.m3.26.512295911 3175270395g
kg-m0.320.651.22.95.911.317.52739.5
lb-ft2.55.09.021.043.082.0126.5195.5286.0
YH4
GRAND
VITARA
HEATER AND VENTILATION 1A-9
1. LO
2. M1
3. M2
4. HI
BLOWER MOTOR RESISTOR
REMOVAL
1) Disconnect negative (±) cable (2) at battery (1).
2) Disable air bag system, if equipped. Refer to DISABLING AIR
BAG SYSTEM in Section 10B.
3) Open glove box (1), then remove screw (2).
4) Remove glove box.
5) Disconnect blower motor resistor (1) at coupler.
6) Remove heater blower resistor (1) by removing its fastening
screw (2).
INSPECTION
Measure each terminal-to-terminal resistance on resistor.
Resistance H-LO: Approx. 2.0
H-M1: Approx. 1.0
H-M2: Approx. 0.4
If measured resistance is incorrect, replace heater blower resistor.
INSTALLATION
1) Install heater blower resistor with screws.
2) Enable air bag system, if equipped. Refer to ENABLING AIR
BAG SYSTEM in Section 10B.
YH4
GRAND
VITARA
1B-20 AIR CONDITIONING (OPTIONAL)
A / C CONTROLLER VOLTAGE VALUES TABLE
TerminalWireCircuitMeasurement
groundNormal valueCondition
AC1-1B/WController main
power supplyGround to
engine (Fig. B)10 ± 14 voltsIgnition switch ON with engine
stopped
AC1-2B/YController main
groundGround to body
(Fig. A)± 0.4 ± 0 voltEngine running
AC1 4Or
Refrigerant
p
ressure switchGround to
0 ± 1 volt
Refrigerant pressure within 225 kPa
(2.3 kg / cm
2, 32.7 psi) to 2548 kPa
(26 kg / cm
2, 370 psi) with engine
running
AC1-4Orpressure switch
inputengine (Fig. B)
10 ± 14 volts
Refrigerant pressure below
196 kPa (2.0 kg / cm
2, 28 psi) or
above 3140 kPa (32 kg / cm
2, 455 psi)
with engine running
AC1 7G/B
A / C switch input
and / or defroster
Ground to
8 ± 14 volts
Blower fan motor switch and A / C or
defroster position switch (see NOTE)
ON with engine running
AC1-7G/Bposition switch
input (see NOTE)engine (Fig. B)
0 ± 1.5 volts
Blower fan motor switch or A / C or
defroster position switch (see NOTE)
OFF with engine running
AC1 9Gr/W
Signal input from
ECM (A / C ON
Ground to10 ± 14 voltsApprove of A / C ON
AC1-9Gr/W(
permission
signal)engine (Fig. B)0 ± 1 voltA / C ON forbid
AC1-13Y/B
Signal output to
ECM (A / C ON
request signal)Ground to engine
(Fig. B)0 ± 1.5 volts
Blower fan motor switch and A / C or
defroster position switch (see NOTE)
ON with engine running at evaporator
thermistor temperature input more
than approx. 2.5C (less than 2.5 V
(5840 )) and refrigerant pressure
switch is ON
10 ± 14 voltsExcept the above-mentioned with
engine running
AC1-16P
Compressor
magnet clutch
relay outputGround to engine
(Fig. B)0 ± 1 volt
Blower fan motor switch and A / C or
defroster position switch ON with
engine running at evaporator
thermistor temperature input more
than approx. 2.5C (less than 2.5 V
(5840 )), refrigerant pressure
switch ON and signal input from ECM
ON
10 ± 14 voltsExcept the above-mentioned with
engine running
YH4
GRAND
VITARA
Pressure ABCD SWITCH
ON
(Continuity)
OFF
(No continuity)
AIR CONDITIONING (OPTIONAL) 1B-47
DUAL PRESSURE SWITCH
INSPECTION
1) Check dual pressure switch (1) on liquid pipe for continuity at
normal temperature (approx. 25C (77F)) when A / C system
has a proper charge of refrigerant and when A / C system (com-
pressor) is under operation. In each of these cases, switch
should show proper continuity.
2) Using a manifold gauge set, check switch for operation at speci-
fied pressure as shown, refer to ªPERFORMANCE DIAGNO-
SISº in this section.
Switch ON : above ªCº and below ªDº
Switch OFF : below ªAº or above ªBº
ªAº: Approx. 200 kPa (2.0 kg / cm
2)
ªBº: Approx. 3200 kPa (32 kg / cm
2)
ªCº: Approx. 230 kPa (2.3 kg / cm
2)
ªDº: Approx. 2800 kPa (28 kg / cm
2)
Tightening torque:
Dual pressure switch: 10 N
.m (1.0 kg-m, 7.5 lb-ft)
YH4
GRAND
VITARA
3B1-22 POWER STEERING (P / S) SYSTEM
1. Flow control spring
1. Oil seal
2. Shaft (pulley)
1. O-ring
1. Side plate
2. Bolt hole
1. Rotor
2. Snap ring
3. Dot
Check free length of relief valve spring.
Free length: Standard 22.0 mm (0.866 in.)
Limit 19.0 mm (0.748 in.)
Replace if any defective is found.
ASSEMBLY
Reverse disassembly procedure for assembly, noting the following.
1) Apply grease to oil seal lip and apply power steering fluid to slid-
ing surface of the shaft then insert pulley's shaft from oil seal side
of the pump body.
ªAº: Grease 99000-25010
2) Apply power steering fluid to O-rings and fit them to pump body.
3) Install side plate to pump body.
NOTE:
Carefully align the dowel pins on the side plate at bolt hole
as shown in figure.
4) Apply power steering fluid to sliding surface of rotor.
5) Install rotor to shaft, directing dot marked side of rotor facing up.
6) Install new snap ring to shaft, then make sure to fit snap into shaft
groove securely.
NOTE:
Never reuse the removed snap ring.
YH4
GRAND
VITARA
3D-22 FRONT SUSPENSION
1. Hydraulic press
2. Front bushing
A: Bushing flange
contacts housing edge
1. Hydraulic press
2. Rear bushing
A: Bushing flange
contacts housing edge
INSTALLATION
1) Front bushing
Press-fit front bushing until its flange contacts housing edge of
control arm, use special tools as shown.
Special Tool
(C): 09951-16060
(F): 09913-85210
NOTE:
When press-fitting bushing, compounding oil or soap water
applied to inside of control arm housing will facilitate work.
2) Rear bushing
Press-fit rear bushing until its flange contacts housing edge of
control arm, use special tools as shown.
Special Tool
(E): 09925-58210
(F): 09913-85210
NOTE:
When press-fitting bushing, compounding oil or soap water
applied to inside of control arm housing will facilitate work.
3) Install control arm to chassis.
Tighten suspension arm nut to specified torque after lowering
hoist and vehicle in non-loaded condition.
Tightening Torque
(a): 85 N
.m (8.5 kg-m, 61.5 lb-ft)
(b): 127 N.m (12.7 kg-m, 92.0 lb-ft)
4) As installation procedure hereafter is the same as that for coil
spring. Refer to ªCOIL SPRINGº in this section.
NOTE:
For any tightening torque other than those specified in text,
refer to ªTORQUE SPECIFICATION TABLEº at the end of
this section.
YH4
GRAND
VITARA
3F-2 WHEELS AND TIRES
The metric term for tire inflation pressure is the kilopascal (kPa).
Tire pressures will usually be printed in both kPa and psi on the Tire
Placard. Metric tire gauges are available from tool suppliers. The
chart, left table, converts commonly used inflation pressures from
kPa to psi.kPakgf / cm2psi
160
180
200
220
240
260
280
300
320
3401.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
3.423
26
29
32
35
38
41
44
47
50
Conversion:1 psi = 6.895 kPa
1 kgf / cm
2 = 98.066 kPa
WHEELS REPLACEMENT
Wheels must be replaced if they are bent, dented, have excessive
lateral or radial runout, leak air through welds, have elongated bolt
holes, if lug nuts won't stay tight, or if they are heavily rusted.
Wheels with greater runout than shown in left figure may cause ob-
jectional vibrations.
Wheels for replacement must be equivalent to the originally
equipped wheels in load capacity, diameter, rim width, off-set and
mounting configuration. A wheel of improper size or type may affect
wheel and bearing life, brake cooling, speedometer / odometer cal-
ibration, ground clearance to the body and chassis.
To measure the wheel runout, it is necessary to use accurate dial
indicator. The tire may be on or off the wheel. The wheel should be
installed to the wheel balancer of the like for proper measurement.
Take measurements of both lateral runout and radial runout at both
inside and outside of the rim flange. With dial indicator set in place
securely, turn the wheel one full revolution slowly and record every
reading of the indicator.
When the measured runout exceeds the specification and correc-
tion by the balancer adjustment is impossible, replace the wheel.
If the reading is affected by welding, paint or scratch, it should be
ignored.
Lateral runout limit ªaº: 1.20 mm (0.047 in.)
Radial runout limit ªbº: 1.20 mm (0.047 in.)
METRIC LUG NUTS AND WHEEL STUDS
All models use metric lug nuts and wheel studs (size M12 x 1.25).
YH4
GRAND
VITARA
1. Stop light switch
BRAKES 5-9
BRAKE PEDAL FREE HEIGHT CHECK
Remove foot rest and displace carpet and dash silencer(s) so as to
measure brake pedal free height between pedal face and asphalt
sheet installed on dash panel.
Brake pedal free height ªaº from asphalt sheet:
208 ± 218 mm (8.19 ± 8.58 in.)
If the measurement is not within the specification, check the posi-
tion of booster push rod clevis and / or stop light switch according
to the instruction shown in this section.
The free height varies depending on installation position of booster
push rod clevis and stop light switch.
BRAKE LIGHT SWITCH ADJUSTMENT
Adjustment should be made as follows when installing switch. Pull
up brake pedal toward you and while holding it there, adjust switch
position so that clearance between end of thread and brake pedal
return cushion (shown as ªbº in figure).
Then tighten lock nut to specified torque.
Clearance ªbº: 1.5 ± 2.0 mm (0.06 ± 0.08 in.)
Tightening Torque
(b): 7.5 N
.m (0.75 kg-m, 5.5 lb-ft)
EXCESSIVE PEDAL TRAVEL CHECK
1) Remove foot rest and displace carpet and dash silencer(s).
2) Start engine.
3) Depress brake pedal a few times.
4) With brake pedal depressed with approximately 30 kg (66 lbs)
load, measure pedal to asphalt sheet clearance ªcº.
Clearance ªcº: over 115 mm (4.53 in.)
5) If clearance ªcº is less than specification, the most possible
cause is either rear brake shoes are worn out beyond limit or air
is in lines.
Should clearance ªcº remain less than specification even after
replacement of brake shoes and bleeding of system, other pos-
sible but infrequent cause is malfunction of rear brake shoe ad-
justers or booster push rod length out of adjustment.