Downloaded from www.Manualslib.com manuals search engine C5HP16EC
SPECIAL FEATURES : AIR CONDITIONING SYSTEM (R 134.a)
Condenser with integral reservoir (continued)
Removing the reservoir (6) from the base (8).
WARNING :This operation requires the greatest care, the base(8)should be kept clean prior to fitting
the new reservoir.
- Remove the reservoir (6) and the protection skirt(7), avoiding WITHOUT F
AILany contact or collision
with other items under the bonnet(Risk of impurities entering the base (8)).
- Check before refitting the reservoir (6)that the base(8)is clean.
(If it is not, clean in and around the base(8)with a paper cloth.)
Preparing the new dryer reservoir
- Remove the black plastic protection cap from the reservoir neck (6), leaving in place the green protec-
tion at the other end, in order to keep the new reservoir (6) sealed when mounting it in the base(8)of
the condenser.
- Use the grease sachet in the replacement kit, to lubricate the threads of the reservoir.
- Use the oil sachet in the replacement kit, to lubricate the two O-ring seals of the reservoir (6).
- Position the reservoir(6), with its new protection skirt (7)from the replacement kit, and engage the
threads of the reservoir (6) in the base (8).
- Check that the downward edge of the skirt (7), covers the base(8) all around it.
AIR
CONDITIONING
248
Downloaded from www.Manualslib.com manuals search engine C5HP16EC
SPECIAL FEATURES : AIR CONDITIONING SYSTEM (R 134.a)
Condenser with integral reservoir (continued)
WARNING :The reservoir (6)contains a drying agent. As soon as the black protection is removed, the reser-
voir must be mounted in the base (8), otherwise there is a risk of damaging the air conditioning circuit.
Screwing the reservoir (6) into the base (8).
- Screw the reservoir(6)manually, until the neck of the reservoir(6) is in contact with the bottom of the
base (8).
- Tighten with a torque spanner and tool [2]at(2)to 1.3 ± 0.1 m.daN.
Fitting the plastic bracket. (New, from the replacement parts kit).
Proceed in the opposite order to removal, tighten the screw(3)to 0.15 m.daN.
AIR
CONDITIONING
249