Page 82 of 2267

NISSAN PRIMERA 1999  Electronic Repair Manual ON BOARD DIAGNOSIS LOGICNCAT0070S03
Diagnostic trouble code Malfunction is detected when ... Check items (Possible cause)
: TP SEN/CIRC A/T
TCM receives an excessively low or high
voltage from the sen

Page 84 of 2267

NISSAN PRIMERA 1999  Electronic Repair Manual Diagnostic ProcedureNCAT0071
1 CHECK DTC WITH ECM
Perform diagnostic test mode II (self-diagnostic results) for engine control.
Refer to EC section [ªMalfunction Indicator (MI)º, ªON BOARD DIAGNOST

Page 85 of 2267

NISSAN PRIMERA 1999  Electronic Repair Manual 4 CHECK THROTTLE POSITION SWITCH CIRCUIT (With CONSULT-II)
With CONSULT-II
1. Turn ignition switch to ªONº position.
(Do not start engine.)
2. Select ªECU INPUT SIGNALSº in ªDATA MONITORº mode f

Page 86 of 2267

NISSAN PRIMERA 1999  Electronic Repair Manual 5 CHECK THROTTLE POSITION SWITCH CIRCUIT (Without CONSULT-II)
Without CONSULT-II
1. Turn ignition switch to ªONº position.
(Do not start engine.)
2. Check voltage between TCM terminals 16, 17 and gr

Page 89 of 2267

NISSAN PRIMERA 1999  Electronic Repair Manual DIAGNOSTIC TROUBLE CODE (DTC) CONFIRMATION
PROCEDURE
NCAT0224S04CAUTION:
IAlways drive vehicle at a safe speed.
IBe careful not to rev engine into the red zone on the
tachometer.
NOTE:
If ªDIAGNOSTIC

Page 93 of 2267

NISSAN PRIMERA 1999  Electronic Repair Manual DescriptionNCAT0228IThe step motor is ON/OFF of 4 aspects changes according to
the signal from TCM.
As a result, the flow of line pressure to primary pulley is
changed and pulley ratio is controlled.

Page 94 of 2267

NISSAN PRIMERA 1999  Electronic Repair Manual 2) Make sure that output voltage of CVT fluid temperature sne-
sor is within the range below.
FLUID TEMP SEN: 0.5 - 1.5V
If out of range, drive the vehicle to decrease the voltage
(warm up the fluid)

Page 95 of 2267

NISSAN PRIMERA 1999  Electronic Repair Manual Diagnostic ProcedureNCAT0230
1 CHECK STEP MOTOR
IIt is monitoring whether ªCVT ratio: 2.32 - 0.47º changes similarly to ªPLY CONT STEP: -3 - 200º by DATA MONITOR mode.
IIf no CONSULT-II, inspect t