Page 1413 of 1691
5.9L, Engine Performance Circuits (3 of 3)
EXTERIOR LIGHTS
Page 1419 of 1691
Ground Distribution Circuit (3 of 3)
HEADLIGHTS
Page 1420 of 1691
Headlight Circuit, W/ DRL & W/ Quad Headlights
Page 1421 of 1691
Headlight Circuit, W/ DRL & W/O Quad Headlights
Page 1422 of 1691
Headlight Circuit, W/O DRL & W/ Quad Headlights
Page 1423 of 1691
Headlight Circuit, W/O DRL & W/O Quad Headlights
HORN
Page 1427 of 1691
Overhead Console Circuit
INTERIOR LIGHTS
Page 1453 of 1691

* Air in fuel system:
* Coolant leak into combustion chamber:
* Block heater malfunction in cold weather:
* Clogged or defective fuel filter:
* Poor fuel quality:
* Fuel injector malfunctioning or loose:
* Restricted or blocked fuel injection or supply lines:
* Intake/exhaust valves not adjusted properly (tight):
* Intake heaters malfunctioning:
* Internal engine damage.
BLUE EXHAUST SMOKE
* Air filter dirty or plugged:
* Air intake system restricted:
* Air leak in intake between turbocharger and intake
manifold:
* Restricted exhaust:
* Restricted turbocharger drain tube:
* Crankcase ventilation plugged:
* Valve stems, guides or seals worn or defective:
* Piston rings improperly gapped, worn or broken:
* Internal engine wear:
* Turbocharger failure.
INTERMITTENTS
INTERMITTENT PROBLEM DIAGNOSIS
Intermittent fault testing requires duplicating circuit or
component failure to identify problem. These procedures may lead to
PCM setting a Diagnostic Trouble Code (FTC) which may help in
diagnosis.
If problem vehicle does not produce DTCs, monitor voltage or
resistance values using a Digital Volt-Ohmmeter (DVOM) while
attempting to reproduce conditions causing intermittent fault. A
status change on DVOM indicates a fault has been located.
Use a DVOM to pinpoint faults. When monitoring voltage,
ensure ignition switch is in ON position or engine is running. Ensure
ignition switch is in OFF position or negative battery cable is
disconnected when monitoring circuit resistance. Status changes on
DVOM during test procedures indicate area of fault.
TEST PROCEDURES
Intermittent Simulation
To reproduce conditions creating an intermittent fault, use
following methods:
* Lightly vibrate component
* Heat component
* Wiggle or bend wiring harness
* Spray component with water
* Remove/apply vacuum source
Monitor circuit/component voltage or resistance while
simulating intermittent. If engine is running, monitor for diagnostic
trouble codes. Use test results to identify a faulty component or
circuit.