1998 SSANGYONG MUSSO torque

[x] Cancel search: torque

Page 788 of 1463

SSANGYONG MUSSO 1998  Workshop Repair Manual 1G1-8  M162 ENGINE INTAKE & EXHAUST
Function Description
A pneumatically actuated resonance flap (5) is located on the
intake manifold, and will be opened and closed by load, which
operates resonance

Page 790 of 1463

SSANGYONG MUSSO 1998  Workshop Repair Manual 1G1-10  M162 ENGINE INTAKE & EXHAUST
Tools Required
103 589 01 39 00 Caulking Bolt
Removal & Installation Procedure
1. Remove the flange bolt from the exhaust manifold, and
disconnect the front exhaus

Page 794 of 1463

SSANGYONG MUSSO 1998  Workshop Repair Manual  M161 ENGINE INTAKE & EXHAUST  1G2-3
Removal & Installation Procedure
1. Release the clamp securing HFM sensor and air cleaner.
2. Disengage the air cleaner assembly and HFM sensor
assembly.
3. Unsere

Page 799 of 1463

SSANGYONG MUSSO 1998  Workshop Repair Manual 1G2-8  M161 ENGINE INTAKE & EXHAUST
Removal & Installation Procedure
1. Disconnect the battery ground cable.
2. Remove idle speed control plug connector (arrow).
3. Disconnect the brake booster vacuum

Page 800 of 1463

SSANGYONG MUSSO 1998  Workshop Repair Manual  M161 ENGINE INTAKE & EXHAUST  1G2-9
EXHAUST MANIFOLD
1 Oxygen Sensor..............................49.5-60.5 Nm
2 Bolt (4 pieces)........................................ 9-11 Nm
3 Upper Cover
4 Nut (1

Page 801 of 1463

SSANGYONG MUSSO 1998  Workshop Repair Manual 1G2-10  M161 ENGINE INTAKE & EXHAUST
4. Unscrew the eleven nuts (4) and remove the exhaust
manifold (5) and gasket (7).
Installation Notice
Tightening  Torque 31.5 - 38.5 Nm
5. Replace the gasket (7)

Page 806 of 1463

SSANGYONG MUSSO 1998  Workshop Repair Manual 1G3-4  OM600 ENGINE INTAKE & EXHAUST
Removal & Installation Procedure
1. Loosen the air duct hose clamp and then remove the air
cleaner and air duct hose.
2. Disconnect the air cleaner housing cover c

Page 809 of 1463

SSANGYONG MUSSO 1998  Workshop Repair Manual OM600 ENGINE INTAKE & EXHAUST  1G3-7
Removal & Installation Procedure
1. Remove the bolt from the exhaust manifold and then remove
the front exhaust pipe.
Installation Notice
Tightening  Torque 15 - 1