MITSUBISHI MONTERO 1998  Service Manual          1) Disconnect pressure hose from power steering pump. Attach
Pressure Gauge (MB990662-01) and Adapters (MB990993-01 and MB990994-
01). See Fig. 2. Tighten fittings to 22-29 ft. lbs. (30-39 N.

Page 1160 of 1501

MITSUBISHI MONTERO 1998  Service Manual end dust cover. Coat lower edge of cup with packing sealer. Install
tie rod ends into adjusting sleeves.
         2) Measure center-to-center distance between tie rod studs
for both tie rod assemblies