MITSUBISHI MONTERO 1998  Service Manual special patterns probe to VAF sensor connector terminal No. 3 or to
PCM connector terminal No. 61.
         2) Start engine. Verify waveform high frequency and low
frequency patterns are of about the

Page 760 of 1501

MITSUBISHI MONTERO 1998  Service Manual continuity between chassis ground and EGR solenoid connector terminal
No. 2. If continuity does not exist, repair wiring harness as
necessary. If continuity exists, condition required to set DTC is no

Page 765 of 1501

MITSUBISHI MONTERO 1998  Service Manual          system.
         3) Using scan tool, read Fuel Tank Differential Pressure
(FTDP) sensor (item 73). Using hand-held pressure/vacuum pump, apply\
0.42 psi. If scan tool reading reaches 0.42 ps

Page 771 of 1501

MITSUBISHI MONTERO 1998  Service Manual          9) Test is complete. Intermittent problem may exist. Road
test vehicle (if necessary) and attempt to duplicate conditions that
caused original complaint. Recheck for DTCs. If no DTCs are disp

Page 780 of 1501

MITSUBISHI MONTERO 1998  Service Manual GENERATOR & REGULATOR 
1998 Mitsubishi Montero
         1998 STARTING & CHARGING SYSTEMS
          Mitsubishi - Generators & Regulators
          Diamante, Eclipse, Galant, Mirage, Montero, Montero Sp

Page 781 of 1501

MITSUBISHI MONTERO 1998  Service Manual          ON-VEHICLE TESTING
          GENERATOR TO BATTERY CONTINUITY TEST
NOTE:    Check generator wiring harness connections and drive belt
         tension and ensure battery is fully charged befor

Page 782 of 1501

MITSUBISHI MONTERO 1998  Service Manual          GENERATOR OUTPUT TEST
NOTE:    A slightly discharged battery should be used, as a fully
         charged battery may not allow full generator output.
         1) Turn ignition off. Disconnect

Page 783 of 1501

MITSUBISHI MONTERO 1998  Service Manual See Fig. 1 . Connect negative voltmeter lead to ground.
         2) Disconnect generator output wire from terminal "B".
Install a 100-amp ammeter in series with terminal "B" and disconnected
output le