1997 SUBARU LEGACY service

[x] Cancel search: service

Page 979 of 3342

SUBARU LEGACY 1997  Service Repair Manual Reverse clutch end play
Unit: mm
C = (M + 0.4)�m
C : Clearance between oil pump housing hose and end
of reverse clutch
M : Distance from case mating surface to upper surface
of reverse clutch
0.4 : G

Page 980 of 3342

SUBARU LEGACY 1997  Service Repair Manual G3M0424
(4) Secure the housing with two nuts.
Tightening torque:
41±3 N⋅m (4.2±0.3 kg-m, 30.4±2.2 ft-lb)
G3M0394
3. TORQUE CONVERTER CLUTCH CASE AND
TRANSMISSION CASE
1) Apply proper amount of li

Page 981 of 3342

SUBARU LEGACY 1997  Service Repair Manual G3M0367
2) Install and route the transmission harness.
CAUTION:
Be careful not to damage the harness.
B3M0418A
3) Install the control valve assembly.
(1) Set the select lever in range“2”.
(2) Inst

Page 982 of 3342

SUBARU LEGACY 1997  Service Repair Manual G3M0345
6) Install the oil cooler outlet pipe, and secure with two
bolts.
Tightening torque:
8±1 N⋅m (0.8±0.1 kg-m, 5.8±0.7 ft-lb)
CAUTION:
Fit the pipe into position. Be careful to avoid twistin

Page 983 of 3342

SUBARU LEGACY 1997  Service Repair Manual G3M0894
3) Install the transfer clutch assembly to the case.
CAUTION:
Be careful not to damage the seal rings.
NOTE:
Insert the clutch assembly fully into position until the bear-
ing shoulder bottoms

Page 984 of 3342

SUBARU LEGACY 1997  Service Repair Manual G3M0431
(2) Measure the distance“”from the transmission
case mating surface to the reduction drive gear end
surface with ST1 and ST2. (On FWD models, measure
distance from end of case to end of b

Page 985 of 3342

SUBARU LEGACY 1997  Service Repair Manual G3M0896
7) Installation of extension case (AWD), transmission
cover (FWD) and transmission case.
AWD model:
(1) Attach the selected thrust needle bearing to the end
surface of reduction drive gear wi

Page 986 of 3342

SUBARU LEGACY 1997  Service Repair Manual G3M0434
2) Installation and adjustment of inhibitor switch
(1) Install the inhibitor switch to the transmission case.
Fit the projecting portion of the switch in the recessed
portion of the case, and