- AIR CONDITIONINGBLOWER UNIT
1186 Author: Date:
1996 TERCEL (RM440U)
BLOWER UNIT
REMOVAL
1. REMOVE COOLING UNIT (See page AC-27)
2. REMOVE BLOWER UNIT
(a) Disconnect the connector from the blower motor.
(b) Disconnect the air inlet damper control cable.
(c) Remove the 2 nut, bolt and the blower unit.
3. REMOVE BLOWER MOTOR
Remove the 3 screws and blower motor.
Page 1193 of 1202
Z12319
1
2 34
12 34AC2XA-01
N02832
1
2 345
1
23
45
I07286
1
2 3
51
2
3
5 AC-64
- AIR CONDITIONINGCOOLING FAN RELAY
1216 Author: Date:
1996 TERCEL (RM440U)
COOLING FAN RELAY
INSPECTION
1. INSPECT COOLING FAN RELAY No. 1 (Marking: FAN)
CONTINUITY
ConditionTester connectionSpecified condition
Constant1 - 2
3 - 4Continuity
Apply B+ between
terminals 1 and 2.3 - 4No continuity
If continuity is not as specified, replace the relay.
2. INSPECT COOLING FAN RELAY No. 2 (Marking: A.C
FAN No. 2) CONTINUITY
ConditionTester connectionSpecified condition
Constant1 - 2
3 - 4Continuity
Apply B+ between
terminals 1 and 2.3 - 5Continuity
If continuity is not as specified, replace the relay.
3. INSPECT COOLING FAN RELAY No. 3 (Marking: A.C
FAN No. 3) CONTINUITY
ConditionTester connectionSpecified condition
Constant1 - 2Continuity
Apply B+ between
terminals 1 and 2.3 - 5Continuity
If continuity is not as specified, replace the relay.
Page 1194 of 1202
N12550
AC3IU-01
- AIR CONDITIONINGCONDENSER FAN
AC-65
1217 Author: Date:
1996 TERCEL (RM440U)
CONDENSER FAN
ON-VEHICLE INSPECTION
INSPECT COOLING FAN MOTORS OPERATION
(a) Disconnect the cooling fan connector.
(b) Connect battery and ammeter.
(c) Check that the cooling fan rotates smoothly, and then
check that the reading on the ammeter.
Specified amperage: 6.9 ± 0.5 A
(d) Connect the fan connector.