SF0X7-03
BO0919
CrackLeakage
Defomation
Z00085
Fulcrum
Length
30 cm
(11.81 in.) Use SST
30 N´m
(310 kgf´cm, 22 ft´lbf)
SST: 09631-22020SST
FU0041
2 - 7 mm (0.08 - 0.28 in.)
Pipe Hose
0 - 3 mm (0 - 0.12 in.)
FI6138
Fuel Inlet Hose
2.5 mm (0.1 in.) or less
- MFIFUEL TANK AND LINE
MF-25
1996 TERCEL (RM440U)
INSPECTION
INSPECT FUEL TANK AND LINE
(a) Check the fuel lines for cracks or leakage, and all connec-
tions for deformation.
(b) Check the fuel tank vapor vent system hoses and connec-
tions for looseness, sharp bends or damage.
(c) Check the fuel tank for deformation, cracks, fuel leakage
or tank band looseness.
(d) Check the filler neck for damage or fuel leakage.
(e) Hose and the tube connections are as shown in the il-
lustration.
(f) Make sure the hose clamps do not interfere with the tank,
tubes, hoses and other parts.
If a problem is found, repair or replace the parts as necessary.