Page 1176 of 1202
AC2WU-02
- AIR CONDITIONINGRECEIVER
AC-47
1996 TERCEL (RM440U)
REMOVAL
1. DISCHARGE REFRIGERANT FROM REFRIGERATION
SYSTEM
Charge system with refrigerant and inspect for leakage of refrig-
erant.
HINT:
At the time of installation, evacuate air from refrigeration sys-
tem.
Specified amount: 600 ± 50 g (21.16 ± 1.76 oz.)
2. REMOVE FRONT GRILLE
3. DISCONNECT 2 LIQUID TUBES FROM RECEIVER
Remove the 2 bolts and both tubes.
Torque: 5.4 N´m (55 kgf´cm, 48 in.´lbf)
NOTICE:
Cap the open fittings immediately to keep moisture dirt out
of the system.
HINT:
At the time of installation, lubricate 2 new O-rings with com-
pressor oil and install the tubes.
4. REMOVE RECEIVER FROM RECEIVER HOLDER
Remove the holder bolts and pull the receiver up ward from the
receiver holder.
HINT:
If receiver was replaced, add compressor oil to compressor.
Add 10 cc (0.4 fl.oz.)
Compressor oil: ND-OIL 9 or equivalent
5. REMOVE RECEIVER HOLDER
Remove the bolt and holder.
Page 1179 of 1202
AC1CY-04
N12238
N12241
AC-50
- AIR CONDITIONINGCONDENSER
1996 TERCEL (RM440U)
REMOVAL
1. DISCHARGE REFRIGERANT FROM REFRIGERATION
SYSTEM
Charge system with refrigerant and inspect for leakage of refrig-
erant.
HINT:
At the time of installation, evacuate air from refrigeration sys-
tem.
Specified amount: 600 ± 50 g (21.16 ± 1.76 oz.)
2. REMOVE RECEIVER (See page AC-47)
3. DISCONNECT LIQUID TUBE AND DISCHARGE TUBE
Torque: 5.4 N´m (55 kgf´cm, 48 in.´lbf)
NOTICE:
Cap the open fittings immediately to keep moisture or dirt
out of the system.
HINT:
Lubricate 2 new O-rings with compressor oil and install them
to the tubes.
4. REMOVE CONDENSER
(a) Remove the 2 radiator upper mountings.
(b) Remove the 2 bolts from condenser upper mountings.
(c) Push the radiator toward the engine.
(d) Push the condenser toward radiator and pull it upward.
HINT:
If condenser was replaced, add compressor oil to compressor.
Add 40 cc (1.4 fl.oz.)
Compressor oil: ND-OIL 9 or equivalent
Page 1189 of 1202
AC1D3-02
I06959
Pressure Switch AC-60
- AIR CONDITIONINGPRESSURE SWITCH
1996 TERCEL (RM440U)
REMOVAL
1. DISCHARGE REFRIGERANT FROM REFRIGERANT
SYSTEM
Charge system with refrigerant and inspect for leakage of refrig-
erant.
HINT:
At the time of installation, evacuate air from refrigeration sys-
tem.
Specified amount: 600 ± 50 g (21.16 ± 1.76 oz.)
2. REMOVE PRESSURE SWITCH FROM LIQUID TUBE
(a) Disconnect the connector.
(b) Remove the pressure switch from the liquid tube.
Torque: 10 N´m (100 kgf´cm, 7 ft´lbf)
HINT:
Lock the switch mount on the tube with an open end
wrench, being careful not to deform the tube, and remove
the switch.
At the time of installation, lubricate a new O-ring with
compressor oil and install them to the switch.