Page 1254 of 1354
SF0R2−02
S01917
ContinuityOhmmeter
S01918
No Continuity
Ohmmeter
S01919
Air
E
G
S01920
Air
Filter E
Battery
− SFIVSV FOR EXHAUST GAS RECIRCULATION (EGR)
SF−43
1996 RAV4 (RM447U)
INSPECTION
1. 4WD:
REMOVE BATTERY
2. REMOVE VSV
3. INSPECT VSV
4. INSPECT VSV FOR OPEN CIRCUIT
Using an ohmmeter, check that there is continuity between the
terminals.
Resistance: At 20°C (68°F): 33 − 39 Ω
If there is no continuity, replace the VSV.
5. INSPECT VSV FOR GROUND
Using an ohmmeter, check that there is no continuity between
each terminal and the body.
If there is continuity, replace the VSV.
6. INSPECT VSV OPERATION
(a) Check that air flows from ports E to G.
(b) Apply battery positive voltage across the terminals.
(c) Check that air flows from port E to the filter.
If operation is not as specified, replace the VSV.
7. REINSTALL VSV
8. 4WD:
REINSTALL BATTERY
Page 1256 of 1354

SF0R4−02
S01912
Ohmmeter
Continuity
S01913
Ohmmeter
No Continuity
S01915
Air
E
F
S01916
BatteryAir
E
F
− SFIVSV FOR EVAPORATIVE EMISSION (EVAP)
SF−45
1996 RAV4 (RM447U)
INSPECTION
1. REMOVE AIR CLEANER CAP ASSEMBLY (See page
ST−4)
2. REMOVE VSV
3. INSPECT VSV
4. INSPECT VSV FOR OPEN CIRCUIT
Using an ohmmeter, check that there is continuity between the
terminals.
Resistance: At 20°C (68°F): 30 −34 Ω
If there is no continuity, replace the VSV.
5. INSPECT VSV FOR GROUND
Using an ohmmeter, check that there is no continuity between
each terminal and the body.
If there is continuity, replace the VSV.
6. INSPECT VSV OPERATION
(a) Check that air does not flow from ports E to F.
NOTICE:
Never apply more than 60 kPa (0.61 kgf/cm
2, 8.7 psi) of
pressure compressed air to the VSV.
(b) Apply battery positive voltage across the terminals.
(c) Check that air flows from ports E to F.
If operation is not as specified, replace the VSV.
7. REINSTALL VSV
8. REINSTALL AIR CLEANER CAP ASSEMBLY
Page 1258 of 1354
SF0R6−02
S01921
ContinuityOhmmeter
S01922
Ohmmeter
No Continuity
S01923
Air
EG
F
S01924
Air
G E
F
Battery
− SFIVSV FOR VAPOR PRESSURE SENSOR
SF−47
1996 RAV4 (RM447U)
INSPECTION
1. REMOVE AIR CLEANER CAP ASSEMBLY (See page
ST−4)
2. REMOVE VSV
3. INSPECT VSV
4. INSPECT VSV FOR OPEN CIRCUIT
Using an ohmmeter, check that there is continuity between the
terminals.
Resistance: At 20°C (68°F): 33 − 39 Ω
If there is no continuity, replace the VSV.
5. INSPECT VSV FOR GROUND
Using an ohmmeter, check that there is no continuity between
each terminal and the body.
If there is continuity, replace the VSV.
6. INSPECT VSV OPERATION
(a) Check that the air flows from ports E to G.
(b) Apply battery positive voltage across the terminals.
(c) Check that the air flows from ports E to F.
If operation is not as specified, replace the VSV.
7. REINSTALL VSV