Page 386 of 1399
BR1DI−01
−
BRAKE ABS ACTUATOR
BR−53
1035
Author: Date:
1996 LAND CRUISER (RM451U)
ABS ACTUATOR
ON−VEHICLE INSPECTION
1. INSPECT BATTERY POSITIVE VOLTAGE
Battery positive voltage: 10 − 14 V
2. DISCONNECT CONNECTORS
(a) Disconnect the connector from the actuator.
(b) Remove the control relay from the actuator bracket.
(c) Disconnect the 2 connectors from the control relay.
3. CONNECT ACTUATOR CHECKER (SST) TO ACTUA-
TOR
(a) Connect the actuator checker (SST) to the actuator, con-
trol relay and body side wire harness through the sub −
wire harness C (SST) and E (SST), as shown.
SST 09990−00150, 09990 −00200, 09990−00210
(b) Connect the red cable of the checker to the battery posi- tive (+) terminal and black cable to the negative ( −) termi-
nal. Connect the black cable of the sub −wire harness to
the battery negative (−) terminal or body ground.
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
Page 391 of 1399

BR1NS−01
BR−58
−
BRAKE ABS ACTUATOR
1996 LAND CRUISER (RM451U)
INSPECTION
1. INSPECT CONTINUITY OF MOTOR RELAY CIRCUIT
(a) Check there is continuity between terminals 9 and 10.
(b) Check there is no continuity between terminals 7 and 8.
If continuity is not as specified, replace the relay.
2. INSPECT OPERATION OF MOTOR RELAY CIRCUIT
(a) Connect the positive (+) lead from the battery to terminal 10 and negative ( −) lead to terminal 9.
(b) Check there is continuity between terminals 7 and 8.
If operation is not as specified, replace the relay.
3. INSPECT CONTINUITY OD SOLENOID RELAY CIR- CUIT
(a) Check there is continuity between terminals 1 and 9.
(b) Check there is no continuity between terminals 2 and 5.
(c) Connect the positive lead from the ohmmeter to terminal 5 and connect negative lead to terminal 4.
(d) Check there is continuity between terminals.
(e) Connect the 2 leads in reverse, and check that there is no
continuity between terminals.
If continuity is not as specified, replace the relay.
HINT:
For the different type ohmmeter, there is no continuity for step
(d), and there is continuity for step (e).
4. INSPECT OPERATION OF SOLENOID RELAY CIR- CUIT
(a) Connect the positive (+) lead from the battery to terminal
1 and negative ( −) lead to terminal 9.
(b) Check there is continuity between terminal 2 and 6.
(c) Check there is no continuity between terminals 2 and 6.
If operation is not as specified, replace the relay.
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
Page 403 of 1399
CH0HN−01
−
CHARGING CHARGING SYSTEM
CH−1
766
Author: Date:
1996 LAND CRUISER (RM451U)
PRECAUTION
CAUTION:
Check that the battery cables are connected to the correct terminals.
Disconnect the battery cables when the battery is given a quick charge.
Do not perform tests with a high voltage insulation resistance tester.
Never disconnect the battery while the engine is running.
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
Page 404 of 1399

CH0EO−02
CH0712
BlueRed
White
Charging
Necessary
OK
Add Distilled
Water
CH−2
−
CHARGING CHARGING SYSTEM
1996 LAND CRUISER (RM451U)
CHARGING SYSTEM
ON−VEHICLE INSPECTION
1. CHECK BATTERY ELECTROLYTE LEVEL AND VOLT-
AGE
(a) Check the electrolyte quantity of each cell.
If under the lower level, replace the battery (or add distilled wa-
ter if possible). check the charging system.
(b) Measure the battery voltage between the negative ( −)
and positive (+) terminals of the battery.
Standard voltage: At 20° C (68°F): 12.7 − 12.9 V
HINT:
Before measuring the voltage, turn the ignition switch
OFF and turn off the electrical systems (headlight, blower
motor, rear defogger etc.).
If the vehicle has been running, wait 20 minutes or more
after the vehicle stops before measuring the battery volt-
age.
If the voltage is less than specification, charge the battery.
HINT:
Check the indicator as shown in the illustration.
2. CHECK BATTERY TERMINALS, FUSIBLE LINK AND FUSES
(a) Check that the battery terminals are not loose or cor-
roded.
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
Page 406 of 1399

CH−4
−
CHARGING CHARGING SYSTEM
1996 LAND CRUISER (RM451U)
If the light does not operate as specified, troubleshoot the dis-
charge warning light circuit.
6. INSPECT CHARGING CIRCUIT WITHOUT LOAD
HINT:
If a battery/generator tester is available, connect the tester to
the charging circuit as per the manufacturer’s instructions.
(a) If a tester is not available, connect a voltmeter and amme-
ter to the charging circuit as follows:
Disconnect the wire from terminal B of the generator
and connect it to the negative ( −) lead of the amme-
ter.
Connect the positive (+) lead of the ammeter to ter-
minal B of the generator.
Connect the positive (+) lead of the voltmeter to ter-
minal B of the generator.
Ground the negative ( −) lead of the voltmeter.
(b) Check the charging circuit as follows:
With the engine running from idle to 2,000 rpm, check the
reading on the ammeter and voltmeter.
Standard amperage 10 A or less
Standard voltage:
at 25° C ’(77°F)14.0 − 15.0 V
at 115°C ’(239° F)13.5 − 14.3 V
If the voltmeter reading is more than standard voltage, replace
the voltage regulator.
If the voltmeter reading is less than the standard voltage, check
the voltage regulator and generator as follows:
With terminal F grounded, start the engine and
check the voltmeter reading of terminal B.
If the voltmeter reading is more than standard volt-
age, replace the voltage regulator.
If the voltmeter reading is less than standard volt-
age, check the generator.
7. INSPECT CHARGING CIRCUIT WITH LOAD
(a) With the engine running at 2,000 rpm, turn on the high
beam headlights and place the heater blower switch at
”HI”.
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
Page 407 of 1399
−
CHARGING CHARGING SYSTEM
CH−5
1996 LAND CRUISER (RM451U)
(b) Check the reading on the ammeter.
Standard amperage: 30 A or more
If the ammeter reading is less than standard amperage, repair
the generator.
HINT:
If the battery is fully charged, the indication will sometimes be
less than standard amperage.
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
Page 410 of 1399
CH0EP−01
CH−8
−
CHARGING GENERATOR
1996 LAND CRUISER (RM451U)
REMOVAL
1. REMOVE BATTERY AND BATTERY TRAY
2. DISCONNECT POWER STEERING (PS) RESERVOIR TANK
3. REMOVE DRIVE BELTS
(a) Loosen the lock bolt, pivot bolt and adjusting bolt.
(b) Remove the 2 drive belts.
4. REMOVE GENERATOR
(a) Disconnect the generator connector.
(b) Remove the rubber cap and nut, and disconnect the gen-
erator wire.
(c) Disconnect the generator wire clamp from the generator.
(d) Remove the lock bolt, bolt, nut and drive belt adjusting bar.
(e) Remove the pivot bolt and generator.
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
Page 421 of 1399
CH06N−03
−
CHARGING GENERATOR
CH−19
1996 LAND CRUISER (RM451U)
INSTALLATION
1. INSTALL GENERATOR
(a) Mount generator on the generator bracket with the pivot
bolt. Do not tighten the bolt yet.
(b) Install the drive belt adjusting bar with the bolt and nut. Torque: 21 N·m (210 kgf·cm, 15 ft·lbf)
(c) Temporarily install the lock bolt.
(d) Connect the generator connector.
(e) Connect the generator wire with the nut and rubber cap.
(f) Connect the generator wire clamp to the generator.
2. INSTALL DRIVE BELTS
(a) Install the drive belts.
(b) Adjust the drive belt with the adjusting bolt (See page
CH−2 ).
(c) Tighten the pivot and adjusting lock bolts. Torque:
Pivot bolt: 59 N·m (600 kgf·cm, 43 ft·lbf)
Lock bolt: 21 N·m (210 kgf·cm, 15 ft·lbf)
3. CONNECT POWER STEERING (PS) RESERVOIR TANK
4. INSTALL BATTERY TRAY AND BATTERY
5. PERFORM ON−VEHICLE INSPECTION (See page CH−2 )
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010