1991 LEXUS SC300 code 32

[x] Cancel search: code 32

Page 92 of 4087

LEXUS SC300 1991  Service Repair Manual 
99
Check voltage between terminals S5 and TS of air conditioner
control assembly connector.
(1) Remove console upper panel. (See page
 BO-111 ).
(2) Remove A/C control assembly with connec-
tors stil

Page 93 of 4087

LEXUS SC300 1991  Service Repair Manual 
Diag. Code 22Compressor Lock Sensor Circuit
CIRCUIT DESCRIPTION
This sensor sends 4 pulses per engine revolution to the air conditioner cont\
rol assembly.
If the number ratio of the compressor speed

Page 94 of 4087

LEXUS SC300 1991  Service Repair Manual 
INSPECTION PROCEDURE
Check compressor
(1). Check compressor drive belt tension (See page AC-104).
(2). Check if the compressor does not lock during with engine started and blo\
wer switch and A/C swi

Page 95 of 4087

LEXUS SC300 1991  Service Repair Manual 
Diag. Code 23Compressor Lock Sensor Circuit
CIRCUIT DESCRIPTION
The pressure switch sends the appropriate signals to the air conditioner co\
ntrol assembly when the air
conditioner  refrigerant press

Page 97 of 4087

LEXUS SC300 1991  Service Repair Manual 
Diag. Code 31, 41Air Mix Damper Position Sensor Circuit
CIRCUIT DESCRIPTION
This sensor detects the position of the air mix
damper and sends the appropriate signals to the
air conditioner control ass

Page 98 of 4087

LEXUS SC300 1991  Service Repair Manual 
Check  voltage between terminals TP and SG of air conditioner control
assembly connector.
(1) Remove console upper panel.(See page  BO±111).
(2) Remove A/C control assembly with connec±
tors still

Page 99 of 4087

LEXUS SC300 1991  Service Repair Manual 
Diag. Code 41Air Mix Servomotor Circuit
CIRCUIT DESCRIPTION
The air mix servomotor is controlled by the A/C control assembly and moves \
the air mix damper to the
desired position.
Code No.Diag. Code

Page 101 of 4087

LEXUS SC300 1991  Service Repair Manual 
Diag. Code 32, 42Air Inlet Damper Position Sensor Circuit
CIRCUIT DESCRIPTION
This sensor detects the position of the air inlet
damper and sends the appropriate signals to the
air conditioner control